steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | ABB |
| Part number | SPTU 240 R2 |
| Alternative part number | SPTU240R2 |
| Product type | Power supply and output relay module |
| Main function | Provides the auxiliary power conversion and output relay functions for compatible ABB protection relay assemblies |
| Supply voltage range | 80 to 265 V AC/DC |
| Supply compatibility | Suitable for both AC and DC auxiliary supplies |
| Trip contact arrangement | Normally open trip contact |
| Power supply design | Transformer-connected, galvanically isolated flyback-type DC/DC converter |
| Internal output voltages | Generates +24 V, ±12 V and +8 V for the relay assembly; +5 V logic voltage is formed within the associated relay module |
| Primary fuse | 1 A slow-blow fuse |
| Rated power | 5 W |
| Insulation test voltage | 2 kV, 50 Hz, 1 minute between primary, secondary and protective earth |
| Construction | Withdrawable plug-in module mounted behind the relay system front panel |
| Application role | Used as the auxiliary supply and output relay module in selected ABB protection relay systems |
| Contact version identifier | R2 version denotes a normally open trip output configuration |
This unit serves as the power supply and output relay module within compatible relay assemblies. It provides the internal operating voltages needed by the relay electronics and also handles output relay functions, including the trip path.
This version is designed for an auxiliary supply range of 80 to 265 V AC/DC. That wide input range makes it suitable for many existing industrial and utility control panels.
Yes. The SPTU 240 R2 is intended for use with either AC or DC auxiliary voltage, provided the supply remains within the stated 80 to 265 V range.
This module is the normally open trip contact version. For applications that require a normally closed trip contact, the corresponding R3 version is typically used instead.
No. It is a plug-in module used inside compatible ABB relay assemblies rather than a complete protection relay on its own.
ABB documentation shows this module used in compatible assemblies such as the SPAM 150 C motor protection relay and the SPAJ 160 C capacitor protection relay, along with other relays built on the same modular platform.
No. This is the wide-range 240 version. The lower-voltage alternative is generally the 48 R2, which is intended for 18 to 80 V DC applications.
Yes. It is a withdrawable module fitted within the host relay assembly, which is useful when a like-for-like replacement is needed in compatible equipment.
The key points to confirm are the auxiliary voltage range, the required trip contact arrangement, and the exact host relay assembly using the module. Matching the module version to the relay design is important, particularly where normally open versus normally closed trip operation matters.
It does both. Alongside the power supply function, it includes the output relay section and the associated control circuitry used by the compatible relay assembly.
In compatible assemblies, the module forms the DC secondary voltages required by the relay electronics, including +24 V, ±12 V and +8 V. The logic voltage used by the measuring module is then derived within the relay electronics.
Yes. The primary side includes a 1 A slow fuse according to the relay documentation for assemblies that use this module.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.