steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part number | 3RW4036-1BB05 |
| Alternative part number | 3RW40361BB05 |
| Manufacturer | Siemens |
| Product type | Soft starter |
| Series | SIRIUS |
| Frame size | S2 |
| Rated operational current | 45 A at 40 °C |
| Rated operational current at 50 °C | 42 A |
| Rated operational current at 60 °C | 39 A |
| Motor power at 400 V | 22 kW |
| Motor power at 500 V | 30 kW |
| Operating voltage | 400 to 600 V AC |
| Operating frequency | 50 to 60 Hz |
| Control supply voltage | 24 V AC/DC |
| Control supply frequency | 50/60 Hz |
| Integrated bypass contact system | Yes |
| Thyristor design | Yes |
| Intrinsic device protection | Yes |
| Motor overload protection | Yes |
| Adjustable current limitation | Yes |
| External reset | Yes |
| Thermistor motor protection evaluation | No |
| Inside-delta circuit | No |
| Motor brake output | No |
| Minimum load | 20% |
| Minimum adjustable motor current for overload protection | 23 A |
| Continuous operating current | 115% of Ie at 40 °C |
| Typical power loss during operation | 6 W |
| Insulation voltage | 600 V |
| Pollution degree | 3 according to IEC 60947-4-2 |
| Number of poles | 3 |
| Main circuit connection type | Screw terminals |
| Auxiliary and control circuit connection type | Screw terminals |
| Auxiliary contacts | 2 NO, 1 changeover |
| Fault indication | Red display |
| Width | 55 mm |
| Height | 160 mm |
| Depth | 170 mm |
| Mounting method | Screw and snap-on mounting |
| Required clearance above | 60 mm |
| Required clearance at side | 30 mm |
| Required clearance below | 40 mm |
| Maximum cable length | 300 m |
| Maximum installation altitude | 5,000 m above sea level |
| Operating ambient temperature | -25 to +60 °C |
| Storage temperature | -40 to +80 °C |
| Derating temperature | 40 °C |
| Front protection class | IP20 |
| Touch protection | Finger-safe from the front |
| Main conductor size, front clamping point | Solid: 2 x 1.5 to 16 mm²; finely stranded with ferrule: 0.75 to 25 mm²; stranded: 0.75 to 35 mm² |
| Main conductor size, back clamping point | Solid: 2 x 1.5 to 16 mm²; finely stranded with ferrule: 1.5 to 25 mm²; stranded: 1.5 to 35 mm² |
| Main conductor size, both clamping points | Solid: 2 x 1.5 to 16 mm²; finely stranded with ferrule: 2 x 1.5 to 16 mm²; stranded: 2 x 1.5 to 25 mm² |
| Auxiliary conductor size | Solid: 2 x 0.5 to 2.5 mm²; finely stranded with ferrule: 2 x 0.5 to 1.5 mm² |
| Typical application | Controlled starting of three-phase motors to help reduce mechanical stress and current peaks during start-up |
This unit is designed to reduce the electrical and mechanical stress that can occur when a three-phase motor starts. By controlling the starting voltage, it helps deliver a smoother ramp-up than direct-on-line starting and is suited to standard motor starting applications.
It is intended for standard-circuit operation on 400 to 600 V AC systems at 50/60 Hz. This makes it suitable for higher-voltage three-phase motor applications within that range.
The rated operational current is 45 A at 40°C. The rating reduces with temperature to 42 A at 50°C and 39 A at 60°C, so panel temperature should be considered during selection.
The unit is rated for up to 22 kW at 400 V and up to 30 kW at 500 V under standard switching conditions at 40°C. It is also listed at 30 hp for 460/480 V and 40 hp for 575/600 V at 50°C.
It uses a 24 V AC/DC control supply. That gives flexibility where the control circuit is already standardised around 24 V control power.
Yes. The unit includes an integrated bypass contact system. This helps reduce heat generation in operation once the motor has reached running speed.
Yes. It includes motor overload protection as part of the device functions. It also supports adjustable current limitation and external reset, but it does not provide thermistor motor protection evaluation.
No. This model is not designed for inside-delta operation. It is intended for standard circuit connection.
This is an S2 frame soft starter. Its approximate dimensions are 55 mm wide, 160 mm high and 170 mm deep, which can be useful when checking panel space before installation.
It is designed for screw mounting and snap-on mounting. The datasheet also specifies mounting position guidance, so installation orientation and surrounding space should be checked during panel layout.
The main, auxiliary and control connections use screw terminals. That makes the unit suitable for applications where secure fixed wiring is preferred.
The device provides signalling contacts for status indication, including ON/RUN, BYPASSED and FAILURE/OVERLOAD functions. In the datasheet, this is shown as 2 NO auxiliary contacts and 1 changeover contact.
For the main circuit, the unit accepts a broad range of conductor sizes depending on conductor type and clamping point, including solid, stranded and finely stranded conductors. For auxiliary contacts, it accepts solid conductors from 0.5 to 2.5 mm² and finely stranded conductors with end treatment from 0.5 to 1.5 mm².
It is designed for operation from -25°C to +60°C, with storage from -40°C to +80°C. Derating starts above 40°C, so the current and application conditions should be reviewed for warmer environments.
The front of the unit is rated IP20 and is described as finger-safe from the front when properly installed. In practice, this means the device is intended for installation inside a suitable control panel or enclosure.
The datasheet gives a maximum cable length of 300 m. Actual application performance can still depend on the wider motor circuit design, but that figure is a useful reference point when assessing suitability.
Yes. The minimum load is specified as 20% of the device rated motor current. This is worth checking where the motor load is especially light or variable.
The combination of a compact S2 frame, integrated bypass contact system, 24 V AC/DC control supply and built-in overload capability makes 3RW4036-1BB05 a practical choice for many standard motor starting duties where space and straightforward wiring matter.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.