steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | CAD323BD |
| Manufacturer | Schneider |
| Series | TeSys D |
| Product Type | Control Relay |
| Contact Composition | 3 Normally Open (NO) + 2 Normally Closed (NC) |
| Rated Operational Voltage (Ue) | <= 690 V AC 25...400 Hz |
| Control Circuit Type | DC Standard |
| Control Circuit Voltage | 24 V DC |
| Rated Impulse Withstand Voltage | 6 kV conforming to IEC 60947 |
| Conventional Free Air Thermal Current (Ith) | 10 A at <= 60 °C |
| Rated Making Capacity | 140 A AC, 250 A DC conforming to IEC 60947-5-1 |
| Rated Short-time Withstand Current (Icw) | 100 A for 1 s, 120 A for 500 ms, 140 A for 100 ms |
| Associated Fuse Rating | 10 A gG conforming to IEC 60947-5-1 |
| Rated Insulation Voltage (Ui) | 690 V conforming to IEC 60947-5-1, 600 V certifications UL, 600 V certifications CSA |
| Mounting Support | Plate, Rail |
| Terminal Type | Spring Terminals for cables 1...2.5 mm², flexible or solid without cable end |
| Operating Time | 15...25 ms coil de-energisation and NC closing, 53...72 ms coil energisation and NO closing |
| Mechanical Durability | 30 Mcycles |
| Operating Rate | 180 cycles per minute |
| Time Constant | 28 ms |
| Inrush Power | 5.4 W at 20 °C |
| Hold-in Power Consumption | 5.4 W at 20 °C |
| Minimum Switching Voltage | 17 V |
| Minimum Switching Current | 5 mA |
| Non-overlap Time | 1.5 ms on de-energisation (between NC and NO contact) |
| Insulation Resistance | > 10 MOhm |
| Dimensions (H x W x D) | 3.9 in x 1.77 in x 3.66 in (99 mm x 45 mm x 93 mm) |
| Product Weight | 1.28 lb (0.58 kg) |
| Standards | BS 4794, EN 60947-5, IEC 60947-5-1, NF C 63-140, VDE 0660 |
| Product Certifications | CSA, UL |
| IP Degree of Protection | IP2X front face conforming to VDE 0106 |
| Protective Treatment | TH conforming to IEC 60068 |
| Ambient Air Temperature for Operation | -40...70 °C |
| Ambient Air Temperature for Storage | -60...80 °C |
| Operating Altitude | 3000 m without derating in temperature |
The control relay falls under utilisation categories AC-14, AC-15 for alternating current, and DC-13 for direct current applications.
Yes, the control relay is designed for both DIN rail mount and plate mount, providing flexibility for various installation requirements.
This control relay is equipped with spring terminals, which can accommodate cables with a stiffness ranging from flexible to solid, without the need for cable ends.
The rated operational voltage for the control relay is up to 690 V AC at a frequency range of 25 to 400 Hz.
The control circuit voltage for this relay is 24 V DC.
The control relay has an IP degree of protection of IP2X for the front face, ensuring a certain level of protection against solid objects.
The conventional free air thermal current rating for this relay is 10 A at temperatures up to 60°C.
The control relay measures 1.77 x 3.66 x 3.9 inches and weighs approximately 0.58 kg.
The mechanical durability of the control relay is rated at 30 million cycles, indicating its robustness and longevity in operation.
The operating temperature range is from -40 to 70°C, while the storage temperature range is from -60 to 80°C.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.