steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | ATS22D75Q |
| Manufacturer | Schneider |
| Product Type | Soft Starter |
| Product Family | Altistart 22 |
| Phases | 3 Phase |
| Rated Supply Voltage | 230 to 440 V (-15% to +10%) |
| Motor Power | 18.5 kW at 230 V, 37 kW at 400 V, 37 kW at 440 V |
| Factory Setting Current | 69 A |
| Power Dissipation | 63 W for standard applications |
| Utilisation Category | AC-53A |
| Type of Start | Start with torque control (current limited to 3.5 In) |
| Starter Rating | 75 A for connection in the motor supply line |
| IP Degree of Protection | IP20 |
| Assembly Style | With heat sink |
| Function Available | Internal bypass |
| Supply Voltage Limits | 195 to 484 V |
| Supply Frequency | 50 to 60 Hz (-10% to +10%) |
| Network Frequency | 45 to 66 Hz |
| Device Connection | In the motor supply line, to the motor delta terminals |
| Control Circuit Voltage | 230 V (-15% to +10%) at 50/60 Hz |
| Control Circuit Consumption | 20 W |
| Discrete Output Number | 2 |
| Discrete Output Type | Relay outputs R1 and R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O |
| Minimum Switching Current | 100 mA at 12 V DC (relay outputs) |
| Maximum Switching Current | 5 A at 250 V AC resistive, 5 A at 30 V DC resistive, 2 A at 250 V AC inductive, 2 A at 30 V DC inductive |
| Discrete Input Number | 3 |
| Discrete Input Type | (LI1, LI2, LI3) logic, 5 mA 4.3 kOhm |
| Discrete Input Voltage | 24 V <= 30 V |
| Discrete Input Logic | Positive logic LI1, LI2, LI3 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA |
| Output Current | 0.4 to 1 Icl adjustable |
| PTC Probe Input | 750 Ohm |
| Communication Port Protocol | Modbus |
| Connector Type | 1 RJ45 |
| Communication Data Link | Serial |
| Physical Interface | RS485 multidrop |
| Transmission Rate | 4800, 9600 or 19200 bps |
| Installed Device | 31 |
| Protection Type | Phase failure line, thermal protection motor, thermal protection starter |
| Marking | CE |
| Type of Cooling | Forced convection |
| Operating Position | Vertical +/- 10 degree |
| Dimensions (H x W x D) | 295 x 145 x 207 mm |
| Net Weight | 12 kg |
| Motor Power Range | 15 to 25 kW at 200 to 240 V 3 phases, 30 to 50 kW at 380 to 440 V 3 phases |
| Motor Starter Type | Soft starter |
| Electromagnetic Compatibility | Conducted and radiated emissions level A IEC 60947-4-2, damped oscillating waves level 3 IEC 61000-4-12, electrostatic discharge level 3 IEC 61000-4-2, immunity to electrical transients level 4 IEC 61000-4-4, immunity to radiated radio-electrical interference level 3 IEC 61000-4-3, voltage/current impulse level 3 IEC 61000-4-5 |
| Standards | EN/IEC 60947-4-2 |
| Product Certifications | CSA, UL, GOST, CCC, C-Tick |
| Vibration Resistance | 1 gn (f= 13 to 200 Hz) EN/IEC 60068-2-6, 1.5 mm (f= 2 to 13 Hz) EN/IEC 60068-2-6 |
| Shock Resistance | 15 gn for 11 ms EN/IEC 60068-2-27 |
| Noise Level | 45 dB |
| Pollution Degree | Level 2 IEC 60664-1 |
| Relative Humidity | 0 to 95% without condensation or dripping water EN/IEC 60068-2-3 |
| Ambient Air Temperature for Operation | -10 to 40 °C without derating, 40 to 60 °C with current derating 2.2% per °C |
| Ambient Air Temperature for Storage | -25 to 70 °C |
| Operating Altitude | <= 1000 m without derating, > 1000 to < 2000 m with current derating of 2.2% per additional 100 m |
The soft starter is designed to control the acceleration and deceleration of asynchronous motors, reducing mechanical stress and electrical peak currents during motor start-up.
This soft starter is commonly used in applications involving pumps and fans, where smooth motor control is essential.
The soft starter operates within a supply voltage range of 230 to 440 volts.
It supports motor power up to 37 kW at 400 V and 440 V, and 18.5 kW at 230 V.
The soft starter provides phase failure protection, thermal protection for both the motor and the starter itself.
The soft starter has an IP20 degree of protection, suitable for installation in a controlled environment.
Yes, it features a Modbus communication protocol via an RS485 interface, allowing for integration into automated systems.
The dimensions are 145 mm in width, 207 mm in depth, and 295 mm in height.
The soft starter can operate in temperatures ranging from -10°C to 40°C without derating, and up to 60°C with derating.
The soft starter weighs approximately 12 kg.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.