steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider |
| Part Number | ATS01N112FT |
| Product Range | Altistart 01 |
| Product Type | Soft starter |
| Intended Motor Type | Asynchronous motors |
| Typical Application | Simple machine motor starting, including conveyors, pumps, fans, compressors, automatic doors, gates, and belt-driven machinery |
| Starter Rating | 12 A |
| Rated Supply Voltage | 110 to 480 V AC, -10% to +10% |
| Supply Voltage Limits | 99 to 528 V AC |
| Supply Frequency | 50/60 Hz, -5% to +5% |
| Network Frequency Limits | 47.5 to 63 Hz |
| Network Phases | Single-phase and three-phase applications |
| Motor Power Rating | 1.5 kW at 230 V single phase; 2.2 kW at 230 V three phase; 5.5 kW at 400 V three phase |
| Horsepower Rating | 1.5 hp at 210 V three phase; 3 hp at 230 V three phase; 7.5 hp at 460 V three phase |
| Utilisation Category | AC-53B according to EN/IEC 60947-4-2 |
| Starting Method | Voltage ramp soft starting |
| Adjustable Starting Time | 1 to 5 seconds |
| Starting Frequency | 1 second / 100 starts per hour; 5 seconds / 20 starts per hour |
| Starting Torque | 30% to 80% of direct-on-line motor starting torque |
| Control Circuit Voltage | 24 V AC/DC ±10% at 30 mA; 110 V AC ±10% at 35 mA; 240 V AC ±10% at 80 mA |
| Current Consumption | 60 A at nominal load |
| Output Voltage | Less than or equal to the supply voltage |
| Integrated Function | Integrated bypass |
| Assembly Style | With heat sink |
| Discrete Output Current | 3 A AC-15; 2 A DC-13 |
| Power Dissipation | 61 W in transient state; 1 W at full load and at end of starting |
| Electrical Connection | Screw connectors and 4 mm screw clamp terminals for control and power circuits |
| Tightening Torque | 0.5 N.m for control connections; 1.9 to 2.5 N.m for power connections |
| Mounting Position | Vertical, ±10 degrees |
| Mounting Method | 35 mm symmetrical rail mounting or screw fixing |
| Height | 124 mm |
| Width | 45 mm |
| Depth | 131 mm |
| Net Weight | 0.28 kg |
| IP Rating | IP20 |
| Pollution Degree | 2 according to EN/IEC 60947-4-2 |
| Operating Temperature | -10 to 40 °C without derating; 40 to 50 °C with current derating of 2% per °C |
| Storage Temperature | -25 to 70 °C |
| Relative Humidity | 5% to 95% without condensation or dripping water |
| Operating Altitude | Up to 1000 m without derating; above 1000 m with derating of 2.2% per additional 100 m |
| Shock Resistance | 15 gn for 11 ms according to EN/IEC 60068-2-27 |
| Vibration Resistance | 1.5 mm peak-to-peak from 3 to 13 Hz; 1 gn from 13 to 150 Hz according to EN/IEC 60068-2-6 |
| Standards | EN/IEC 60947-4-2 |
| Certifications | CE, UL, CSA, CCC, C-Tick, GOST, B44.1-96/ASME A17.5 for starter wired to the motor delta terminal |
| Compatibility Code | ATS01N1 |
This is an Altistart 01 soft starter for asynchronous motors. It is designed to reduce mechanical stress during motor start-up by applying a controlled voltage ramp instead of switching the motor directly across the line.
The rated supply voltage range is 110 to 480 V AC, with supply voltage limits of 99 to 528 V. It is suitable for 50/60 Hz applications, with a network frequency range of 47.5 to 63 Hz.
The ATS01N112FT has an IcL starter rating of 12 A. It is listed for AC-53B utilisation category according to EN/IEC 60947-4-2.
Typical motor ratings include 1.5 kW at 230 V single phase, 2.2 kW at 230 V three phase, and 5.5 kW at 400 V three phase. Horsepower ratings include 3 hp at 230 V three phase and 7.5 hp at 460 V three phase.
Yes. This model includes an integrated bypass, which helps reduce heat generation once the motor has completed its start-up phase.
It uses voltage ramp starting. The starting time is adjustable from 1 to 5 seconds, and the starting torque can be adjusted from 30% to 80% of the motor’s direct-on-line starting torque.
The unit measures approximately 45 mm wide, 124 mm high, and 131 mm deep. Its net weight is approximately 0.28 kg.
It is intended to be mounted vertically, with an allowable mounting angle of plus or minus 10 degrees. The unit can be mounted on a 35 mm symmetrical rail or fixed by screws using its mounting points.
It is suited to simple machine applications where reduced starting shock is beneficial, such as conveyors, pumps, fans, compressors, automatic doors, gates, overhead travelling cranes for horizontal loads, and belt-driven machinery.
The operating temperature range is -10 to 40 °C without derating. It can operate from 40 to 50 °C with current derating of 2% per °C.
The enclosure rating is IP20. This means it is intended for installation within a suitable electrical panel or enclosure for the application environment.
The control circuit can use 24 V AC/DC at 30 mA, 110 V AC at 35 mA, or 240 V AC at 80 mA, each with a tolerance of plus or minus 10%.
For the power circuit, the screw clamp terminals accept rigid conductors up to 1 to 10 mm² for a single conductor, or 1 to 6 mm² for two conductors. Flexible conductor sizes depend on whether cable ends are used.
The unit conforms to EN/IEC 60947-4-2 and carries certifications including UL, CSA, C-Tick, CCC, GOST, and CE marking.
For the example three-phase power supply connection shown for this device, a line contactor is specified as part of the sequence, along with a motor circuit-breaker, control protection fuses, and pushbuttons.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.