steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Omron |
| Part Number | CQM1-ARM21 |
| Alternative Part Number | CQM1ARM21 |
| Product Type | AS-Interface Master Unit |
| Product Category | PLC System Interface Module |
| Compatible Platform | Omron CQM1 programmable controller system |
| Function | Connects a CQM1 controller to an AS-Interface network for cyclic communication with distributed sensors, actuators and I/O devices |
| Communication Standard | AS-Interface Complete Specification V2.04 |
| Master Profile | M0 |
| Maximum Number of Slaves | 31 |
| Maximum I/O Capacity | 248 points: 124 inputs and 124 outputs |
| I/O per Slave | Up to 4 inputs and 4 outputs |
| Allocated PLC Words | Switch-selectable from 3 input and 3 output words to 8 input and 8 output words |
| AS-Interface Line Voltage | 30.5 V DC nominal |
| AS-Interface Line Current Consumption | 100 mA maximum |
| Internal Current Consumption | 300 mA maximum at 5 V DC from the PLC power supply |
| Minimum Communication Cycle Time | 5.148 ms |
| Maximum Network Length | 100 m without repeaters; up to 300 m using two repeaters and additional AS-Interface power supplies |
| Network Topologies | Line, star, branched line or tree |
| Network Termination | Not required |
| External Connections | Two ASI+ and two ASI− connections via a detachable terminal block with M3 screw terminals |
| Configuration Functions | Slave address assignment, configuration storage, parameter reading and writing, and connected-slave detection |
| Operating Modes | Protected, configuration and setup modes |
| Status Indicators | LEDs for unit operation, general error, AS-Interface power failure, configuration error, configuration mode, auto-programming availability and slave status |
| Recommended Mounting Position | Rightmost I/O unit position in the CQM1 system |
| Maximum Units per CPU | One |
| Operating Temperature | 0°C to 55°C |
| Storage Temperature | −20°C to 75°C |
| Operating Humidity | 10% to 90% RH, non-condensing |
| Approximate Weight | 200 g, including front cover and terminal block |
| Conformity Standards | EN 50081-2 and EN 61131-2 |
| Commodity Code | 851762 |
It is an AS-Interface master unit that connects a CQM1 PLC system to AS-Interface sensors, actuators and remote I/O slaves. It manages cyclic I/O data exchange and network configuration.
The CQM1-ARM21 is designed for the CQM1 range of programmable controllers. It can be fitted to any CQM1 CPU type, subject to the available I/O channel capacity.
The maximum is selectable through the channel switches. Depending on the I/O word allocation, the unit can address between 11 and 31 AS-Interface slaves.
With the channel switches set for the maximum allocation, the unit can handle up to 124 input points and 124 output points across 31 addressed slaves.
A maximum of one AS-Interface master unit can be installed per CQM1 CPU.
The recommended mounting position is as the rightmost I/O unit in the CQM1 system. The available I/O channels of the selected CPU must also be considered.
The module consumes up to 300 mA at 5 V DC from the PLC power supply and less than 100 mA at the nominal 30.5 V DC AS-Interface line.
Yes. A suitable AS-Interface power supply with the required decoupling characteristics should be used and sized for the master plus all connected slaves.
The AS-Interface network can be arranged as a line, star, branched line or tree. Bus termination is not required.
The total network cable length is normally limited to 100 metres. With two repeaters and additional AS-Interface power supplies, the network can be extended to a maximum of 300 metres.
The unit has a detachable terminal block with two ASI+ and two ASI− connections using M3 screw terminals.
The front panel includes indicators for operating status, general errors, AS-Interface power failure, configuration errors, automatic slave addressing availability, operating mode and individual slave activity.
A flashing slave indicator normally means that the slave is included in the projected configuration but is not active. If indicator 0 flashes, a slave with address 0 has been detected.
The CER indicator illuminates when the detected network configuration differs from the configuration stored in the master, or when a slave with address 0 is present.
The module provides Protected Mode, Configuration Mode and Setup Mode. Protected Mode uses the stored network arrangement, Configuration Mode accepts detected slaves, and Setup Mode allows configuration data, slave addresses and parameters to be managed through the PLC.
Yes. In Setup Mode, the CQM1-ARM21 can change a connected slave from address 0 to a valid operating address, allowing network commissioning without a separate handheld addressing device.
The channel switches select an allocation from 3 input and 3 output IR words up to 8 input and 8 output IR words. This setting also determines the highest usable slave address and I/O capacity.
The specified operating temperature is 0°C to 55°C, with a relative humidity range of 10% to 90% without condensation. The storage temperature range is −20°C to 75°C.
The unit has dimensions comparable with standard CQM1 I/O modules and weighs approximately 200 g, including the front cover and detachable terminal block.
It operates to the AS-Interface Complete Specification V2.04 and uses the M0 master profile. Communication takes place over the AS-Interface two-wire network.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.