What does this pressure sensor do?
It measures fluid pressure and provides a 4–20 mA analogue signal for a control or monitoring system. A four-digit display shows the reading locally.
What is its measuring range?
The rated pressure range is 0–250 bar. The maximum permissible accidental pressure is 750 bar, which is not an extension of the measuring range.
What power supply does it require?
It is rated for a 24 V DC supply and accepts 17–33 V DC. Its current consumption is no more than 50 mA.
What electrical connection and output does it use?
It has a four-pin male M12 connector and a 4–20 mA analogue output.
What process connection does it have?
It uses a female G 1/4 fluid connection conforming to DIN 3852-Y. Check the mating fitting and sealing arrangement before installation.
Which fluids can it measure?
The listed fluids are fresh water at 0–80 °C, and air, hydraulic oil and refrigeration fluid at −20–80 °C.
How accurate is the pressure measurement?
The stated overall accuracy is no more than 1% of the measuring range. The analogue output has a stated linearity error of no more than 0.5% of the measuring range.
How quickly does the output respond?
The analogue output response time is no more than 10 ms. The display response can be set to fast, normal or slow.
What environmental conditions is it rated for?
The operating ambient temperature range is −20–80 °C. The datasheet lists IP65 and IP67 degrees of protection.
What are its dimensions?
The sensor measures approximately 42 mm deep, 88 mm high and 41 mm wide, with a stated net weight of 0.186 kg.