steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Part number | 3RT2325-1AP60 |
| Alternative part number | 3RT23251AP60 |
| Product range | SIRIUS |
| Product type | Power contactor |
| Type designation | 3RT23 |
| Contactor size | S0 |
| Main contact arrangement | 4-pole, 4 normally open main contacts |
| Auxiliary contacts | Integrated 1 normally open and 1 normally closed auxiliary contact |
| Utilisation category | AC-1 rated contactor, also suitable for AC-3 and AC-4 applications within stated ratings |
| Rated operational current, AC-1 | 35 A at 400 V and 40 °C ambient temperature |
| Rated operational current, AC-1 at higher ambient temperature | 30 A up to 690 V at 60 °C ambient temperature |
| Rated operational current, AC-3 | 15.5 A at 400 V |
| Rated operational current, AC-4 | 15.5 A at 400 V |
| Rated operating voltage | Up to 690 V AC at 50/60 Hz |
| Rated insulation voltage | 690 V |
| Surge voltage withstand | 6 kV for main, auxiliary and control circuits |
| Rated operating power, AC-3 | 7.5 kW at 400 V |
| Rated operating power, AC-4 | 7.5 kW at 400 V |
| Control supply voltage | 220 V AC at 50 Hz; 240 V AC at 60 Hz |
| Coil operating range | 0.8 to 1.1 times rated control supply voltage |
| Coil pick-up power | 68 VA at 50 Hz; 67 VA at 60 Hz |
| Coil holding power | 7.9 VA at 50 Hz; 6.5 VA at 60 Hz |
| Switching mechanism connection | Standard A1-A2 coil connection |
| Closing delay | 8 to 40 ms at AC |
| Opening delay | 4 to 16 ms at AC |
| Arcing time | 10 ms |
| Maximum no-load switching frequency | 5,000 operations per hour at AC |
| Maximum operating frequency, AC-1 | 1,000 operations per hour |
| Mechanical service life | Typically 10,000,000 switching cycles |
| Front protection rating | IP20 |
| Touch protection | Finger-safe from the front for vertical contact |
| Ambient operating temperature | -25 °C to +60 °C |
| Storage temperature | -55 °C to +80 °C |
| Maximum installation altitude | 2,000 m above sea level |
| Relative humidity | Up to 95% during operation |
| Mounting method | Screw mounting or snap-on mounting to a 35 mm standard rail according to DIN EN 60715 |
| Mounting position | ±180° rotation on a vertical mounting surface; forward or backward tilt up to ±22.5° |
| Side-by-side mounting | Suitable for side-by-side mounting with 0 mm side spacing |
| Dimensions | 85 mm high x 60 mm wide x 97 mm deep |
| Main circuit terminals | Screw-type terminals |
| Auxiliary and control circuit terminals | Screw-type terminals |
| Main contact conductor size | 1 to 10 mm² solid, stranded or finely stranded with core end processing |
| Auxiliary contact conductor size | 0.5 to 2.5 mm² solid, stranded or finely stranded with core end processing |
| Main contact AWG range | AWG 16 to AWG 8 |
| Auxiliary contact AWG range | AWG 20 to AWG 14 |
| Auxiliary contact rating, AC-12 | Maximum 10 A |
| Auxiliary contact rating, AC-15 | 10 A at 230 V; 3 A at 400 V; 2 A at 500 V; 1 A at 690 V |
| Auxiliary contact rating, DC-12 | 10 A at 24 V; 6 A at 48 V and 60 V; 3 A at 110 V; 2 A at 125 V; 1 A at 220 V; 0.15 A at 600 V |
| Auxiliary contact rating, DC-13 | 10 A at 24 V; 2 A at 48 V; 1 A at 110 V; 0.9 A at 125 V; 0.3 A at 220 V; 0.1 A at 600 V |
| UL auxiliary contact rating | A600 / Q600 |
| Main circuit fuse protection | gG 63 A for coordination type 1; gG 20 A for coordination type 2 |
| Auxiliary circuit fuse protection | gG 10 A |
| Bus communication | Not included |
| Typical application | Switching and control of electrical loads such as heating circuits, lighting circuits, distribution circuits and motor loads within the stated AC ratings |
This is a SIRIUS 3RT23 contactor designed for switching electrical loads in industrial control panels. It is a 4-pole contactor with four normally open main contacts and an integrated auxiliary contact arrangement of 1 NO + 1 NC.
The contactor is rated for AC-1 duty at 35 A at 400 V when used at an ambient temperature of 40 °C. At 60 °C ambient temperature, the AC-1 rating is 30 A.
The coil is an AC-operated coil rated at 220 V AC at 50 Hz and 240 V AC at 60 Hz. The coil terminals are marked A1 and A2.
It has four main poles, all normally open. The main terminal arrangement is typically marked 1/L1 to 2/T1, 3/L2 to 4/T2, 5/L3 to 6/T3, and 7/L4 to 8/T4.
Yes, it can be used for motor switching where the electrical ratings match the application. For AC-3 duty at 400 V, the rated operational current is 15.5 A and the rated operating power is 7.5 kW.
The contactor includes one normally open and one normally closed instantaneous auxiliary contact. The auxiliary contacts are commonly used for indication, interlocking, and control circuit feedback.
It uses screw-type terminals for the main current circuit, auxiliary contacts, and control coil connections. This makes it suitable for conventional panel wiring using prepared conductors.
The main terminals accept solid, stranded, or finely stranded conductors from 1 mm² to 10 mm², depending on conductor preparation and the number of conductors fitted.
The auxiliary terminals accept solid or stranded conductors from 0.5 mm² to 2.5 mm², including finely stranded conductors with core end processing.
It can be mounted by screw fixing or snapped onto a 35 mm standard mounting rail according to DIN EN 60715. Side-by-side mounting is permitted with 0 mm spacing at the side.
The contactor measures approximately 85 mm high, 60 mm wide, and 97 mm deep. It is an S0 size contactor.
The permitted operating temperature range is -25 °C to +60 °C. For storage, the stated range is -55 °C to +80 °C.
The front protection class is IP20. The front is also described as finger-safe for vertical contact from the front.
The rated insulation voltage for the main, auxiliary, and control circuits is 690 V, with degree of pollution 3. The rated surge voltage resistance is 6 kV.
The specified fuse protection for the main circuit is gG 63 A for coordination type 1 and gG 20 A for assignment type 2, both stated at 690 V and 100 kA.
The no-load switching frequency is rated at up to 5,000 operations per hour for AC operation. For AC-1 duty, the maximum operating frequency is 1,000 operations per hour.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.