steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Part Number | 3RK1400-1DQ02-0AA3 |
| Alternative Part Number | 3RK14001DQ020AA3 |
| Product Type | AS-Interface K60 compact digital I/O module |
| Application | Decentralised digital input and output connection for field-mounted industrial automation equipment |
| Module Configuration | 2 × (2 digital inputs / 2 digital outputs) |
| Digital Inputs | 4 PNP inputs for 2-wire or 3-wire devices |
| Digital Outputs | 4 PNP transistor outputs |
| I/O Sockets | 4 × M12 standard sockets with Y assignment |
| Output Rated Current | 1 A per output at 24 V DC |
| Maximum Total Output Current | 4 A |
| Sensor Supply Capacity | 200 mA for all inputs at 40 °C |
| AS-Interface Operating Voltage | 26.5–31.6 V |
| Maximum AS-Interface Current Consumption | 270 mA |
| Auxiliary Supply | 20–30 V DC external AUX POWER required for the output circuits |
| Input High Switching Level | Minimum 10 V |
| Input Current | Minimum 6 mA at signal 1; maximum 1.5 mA at signal 0 |
| Slave Type | Standard AS-Interface slave |
| I/O Configuration | 7 |
| ID / ID2 Code | F / F |
| Addressing | Front-mounted addressing socket |
| Output Protection | Integrated short-circuit and inductive-load protection |
| Monitoring | Integrated watchdog |
| Status Indicators | Yellow I/O LEDs, green auxiliary-power LED and green/red AS-Interface diagnostic LEDs |
| Ingress Protection | IP67 |
| Operating Temperature | -25 to +85 °C |
| Storage Temperature | -40 to +85 °C |
| Dimensions | 60 mm wide × 152 mm high × 29 mm deep |
| Mounting | DIN rail or wall mounting using K60 mounting plate 3RK1901-0CA00 |
| Shock Resistance | 15 g for 11 ms |
| Commodity Code | 853710 |
It is a Siemens K60 compact digital I/O module designed to connect field sensors and actuators to an AS-Interface network.
The module provides four digital inputs and four digital outputs, arranged as two groups of two inputs and two outputs.
It operates as a standard slave on an AS-Interface, commonly abbreviated to AS-i, industrial communication network.
The inputs and outputs use four standard M12 screw-type sockets with Y-assigned connections, allowing two signals to be carried through each applicable socket.
The enclosure is rated IP67, making it suitable for installation directly in industrial field environments when correctly fitted and connected.
The specified AS-Interface operating voltage range is 26.5 to 31.6 V.
Yes. An external AUX POWER supply of 20 to 30 V DC is required for the output circuits. This supply must comply with PELV requirements and protection class III.
The four DC digital inputs are designed for PNP signals and can be connected using two-wire or three-wire technology. The minimum high switching level is 10 V.
The module has four PNP transistor outputs. Each output is rated at 1 A at 24 V DC, with a maximum combined output current of 4 A.
The sensor supply is provided through AS-i and has a combined current capacity of up to 200 mA for all inputs at an ambient temperature of 40°C.
The maximum total current drawn from the AS-Interface network is 270 mA.
Yellow LEDs indicate input and output states, a green LED indicates auxiliary power, and green and red LEDs display AS-Interface and diagnostic conditions.
The specified operating temperature range is -25°C to +85°C. The storage temperature range is -40°C to +85°C.
The Siemens 3RK1400-1DQ02-0AA3 measures approximately 60 mm wide, 152 mm high and 29 mm deep.
No. The K60 mounting plate must be ordered separately. The specified compatible mounting plate is 3RK1901-0CA00.
It can be installed on a standard rail or mounted to a wall using the appropriate K60 compact-module mounting plate.
Addressing is carried out through the dedicated addressing socket located on the front of the module.
The outputs include integrated short-circuit and inductive-load protection, together with a watchdog function.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.