steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | GVAN20 |
| Product Type | Auxiliary contact block |
| Range / Series | TeSys (TeSys Deca) |
| Contact Configuration | 2 x NO (normally open) |
| Mounting Location | Left-side auxiliary module for compatible TeSys GV devices |
| Compatible Devices | GV2L, GV2LE, GV2ME, GV2P, GV2RT, GV3L, GV3P |
| Rated Insulation Voltage (Ui) | 690 V AC (IEC 60947-1); 600 V AC (UL 508); 600 V AC (CSA C22.2 No 14) |
| Rated Operational Voltage (Ue) | 48–690 V AC; 24–240 V DC |
| Conventional Free Air Thermal Current (Ith) | 6 A |
| Minimum Switching Voltage | 17 V |
| Minimum Switching Current | 5 mA |
| Utilisation Category (AC) | AC-15 (rated operational power values below) |
| Rated Operational Power (AC-15) | 300 VA @ 48 V AC; 500 VA @ 110–127 V AC; 720 VA @ 230–240 V AC; 850 VA @ 380–415 V AC; 650 VA @ 440 V AC; 500 VA @ 500 V AC; 414 VA @ 690 V AC |
| Utilisation Category (DC) | DC-13 (rated operational power values below) |
| Rated Operational Power (DC-13) | 240 W @ 48 V DC; 180 W @ 60 V DC; 140 W @ 24 V DC; 140 W @ 110 V DC; 120 W @ 240 V DC |
| Terminal Type | Screw clamp terminals |
| Conductor Capacity (Solid) | 1.0–2.5 mm² (1 or 2 conductors per terminal) |
| Conductor Capacity (Flexible, without ferrule) | 0.75–2.5 mm² (1 or 2 conductors per terminal) |
| Conductor Capacity (Flexible, with ferrule) | 0.75–1.5 mm² (1 or 2 conductors per terminal) |
| Tightening Torque | 1.4 N·m (screw clamp terminals) |
| Mechanical Durability | 100,000 cycles |
| Colour | Dark grey |
| Dimensions (W x D x H) | 9.3 mm x 66 mm x 89 mm |
| Net Weight | 0.05 kg |
| Environmental Characteristic | Normal environment |
| Certification | UKCA |
| Part Description | Schneider Electric GVAN20 is a compact 2‑NO auxiliary contact block designed to add signalling and interlocking contacts to compatible TeSys GV2/GV3 manual motor starter and protector assemblies, mounting on the left-hand side with screw-clamp wiring. |
It adds extra signalling contacts to a compatible Schneider TeSys manual motor starter/circuit breaker, allowing you to monitor status (for example, run indication or auxiliary interlocking) via two normally-open (NO) contacts.
It is designed for use with Schneider TeSys GV manual motor starters/circuit breakers including GV2L, GV2LE, GV2ME, GV2P, GV2RT, GV3L and GV3P (per the manufacturer compatibility list).
It provides 2 x NO (normally-open) auxiliary contacts.
It mounts on the left-hand side of the compatible GV2/GV3 device.
It uses screw clamp terminals.
For solid conductors, it accepts 1.0 to 2.5 mm². For flexible conductors, it accepts 0.75 to 2.5 mm² without a cable end, or 0.75 to 1.5 mm² with a cable end.
Rated operational voltage is 48 to 690 V AC and 24 to 240 V DC. Rated insulation voltage is up to 690 V (IEC 60947-1) and 600 V (UL 508 / CSA C22.2 No 14).
The conventional free-air thermal current (Ith) is 6 A.
Yes. The minimum switching current is 5 mA and the minimum switching voltage is 17 V, which supports low-level control and signalling circuits when correctly applied.
It is specified for common industrial control categories such as AC-15 and DC-13. Example ratings include 720 VA at 230–240 V AC-15 and 120 W at 240 V DC-13 (electrical durability stated at 100,000 cycles under the listed conditions).
Mechanical durability is specified at 100,000 cycles.
Approximate dimensions are 89 mm (H) x 9.3 mm (W) x 66 mm (D), with a typical net weight around 0.05 kg.
It is intended for use in a normal industrial environment as defined by the manufacturer for this accessory range.
The product is listed with UKCA certification and is described by the manufacturer as compliant with EU RoHS; it is also provided within the manufacturer’s environmental disclosure framework (including WEEE disposal requirements where applicable).
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.