Schneider GVAN20 is a TeSys auxiliary contact block designed to add additional signalling and control points to compatible TeSys GV2 and GV3 manual motor starter/protector devices. It mounts on the left side of the starter, providing two normally open (2 NO) auxiliary contacts for functions such as run/trip status indication, interlocking, PLC input signalling, and control circuit feedback.

Rated for 48 to 690 V AC and 24 to 240 V DC, the GVAN20 offers a 6 A conventional free-air thermal current and reliable operation down to 5 mA / 17 V for low-level signalling. Screw clamp terminals accept solid or flexible conductors from 0.75 to 2.5 mm², making panel wiring straightforward. The compact dark grey module measures 9.3 mm (W) x 66 mm (D) x 89 mm (H), supporting space-efficient integration in control panels.
Specification Description
Manufacturer Schneider Electric
Part Number GVAN20
Product Type Auxiliary contact block
Range / Series TeSys (TeSys Deca)
Contact Configuration 2 x NO (normally open)
Mounting Location Left-side auxiliary module for compatible TeSys GV devices
Compatible Devices GV2L, GV2LE, GV2ME, GV2P, GV2RT, GV3L, GV3P
Rated Insulation Voltage (Ui) 690 V AC (IEC 60947-1); 600 V AC (UL 508); 600 V AC (CSA C22.2 No 14)
Rated Operational Voltage (Ue) 48–690 V AC; 24–240 V DC
Conventional Free Air Thermal Current (Ith) 6 A
Minimum Switching Voltage 17 V
Minimum Switching Current 5 mA
Utilisation Category (AC) AC-15 (rated operational power values below)
Rated Operational Power (AC-15) 300 VA @ 48 V AC; 500 VA @ 110–127 V AC; 720 VA @ 230–240 V AC; 850 VA @ 380–415 V AC; 650 VA @ 440 V AC; 500 VA @ 500 V AC; 414 VA @ 690 V AC
Utilisation Category (DC) DC-13 (rated operational power values below)
Rated Operational Power (DC-13) 240 W @ 48 V DC; 180 W @ 60 V DC; 140 W @ 24 V DC; 140 W @ 110 V DC; 120 W @ 240 V DC
Terminal Type Screw clamp terminals
Conductor Capacity (Solid) 1.0–2.5 mm² (1 or 2 conductors per terminal)
Conductor Capacity (Flexible, without ferrule) 0.75–2.5 mm² (1 or 2 conductors per terminal)
Conductor Capacity (Flexible, with ferrule) 0.75–1.5 mm² (1 or 2 conductors per terminal)
Tightening Torque 1.4 N·m (screw clamp terminals)
Mechanical Durability 100,000 cycles
Colour Dark grey
Dimensions (W x D x H) 9.3 mm x 66 mm x 89 mm
Net Weight 0.05 kg
Environmental Characteristic Normal environment
Certification UKCA
Part Description Schneider Electric GVAN20 is a compact 2‑NO auxiliary contact block designed to add signalling and interlocking contacts to compatible TeSys GV2/GV3 manual motor starter and protector assemblies, mounting on the left-hand side with screw-clamp wiring.

What does this auxiliary contact block do?

It adds extra signalling contacts to a compatible Schneider TeSys manual motor starter/circuit breaker, allowing you to monitor status (for example, run indication or auxiliary interlocking) via two normally-open (NO) contacts.

Which Schneider devices is it compatible with?

It is designed for use with Schneider TeSys GV manual motor starters/circuit breakers including GV2L, GV2LE, GV2ME, GV2P, GV2RT, GV3L and GV3P (per the manufacturer compatibility list).

How many contacts does it provide and what type are they?

It provides 2 x NO (normally-open) auxiliary contacts.

Where does it mount on the base device?

It mounts on the left-hand side of the compatible GV2/GV3 device.

What terminal type does it use?

It uses screw clamp terminals.

What wire sizes can be connected to the terminals?

For solid conductors, it accepts 1.0 to 2.5 mm². For flexible conductors, it accepts 0.75 to 2.5 mm² without a cable end, or 0.75 to 1.5 mm² with a cable end.

What are the rated voltages for this auxiliary contact block?

Rated operational voltage is 48 to 690 V AC and 24 to 240 V DC. Rated insulation voltage is up to 690 V (IEC 60947-1) and 600 V (UL 508 / CSA C22.2 No 14).

What is the conventional free-air thermal current rating?

The conventional free-air thermal current (Ith) is 6 A.

Can it be used for low-level signalling?

Yes. The minimum switching current is 5 mA and the minimum switching voltage is 17 V, which supports low-level control and signalling circuits when correctly applied.

What are the typical utilisation categories and switching capabilities?

It is specified for common industrial control categories such as AC-15 and DC-13. Example ratings include 720 VA at 230–240 V AC-15 and 120 W at 240 V DC-13 (electrical durability stated at 100,000 cycles under the listed conditions).

How durable is it for repeated switching?

Mechanical durability is specified at 100,000 cycles.

What are the dimensions and approximate weight?

Approximate dimensions are 89 mm (H) x 9.3 mm (W) x 66 mm (D), with a typical net weight around 0.05 kg.

What environmental conditions is it intended for?

It is intended for use in a normal industrial environment as defined by the manufacturer for this accessory range.

Does it meet common UK/EU compliance expectations?

The product is listed with UKCA certification and is described by the manufacturer as compliant with EU RoHS; it is also provided within the manufacturer’s environmental disclosure framework (including WEEE disposal requirements where applicable).

  • Adding two normally-open auxiliary signalling points to compatible TeSys GV2/GV3 manual motor starters for remote status indication
  • Providing feedback to PLC or relay logic to confirm starter actuation for basic interlocking and sequencing
  • Switching pilot lamps, beacons, or panel indicators to show motor starter ON status from the control cabinet
  • Enabling BMS/SCADA input signalling from motor protection starters in building services and plant control panels
  • Expanding available control contacts in retrofit panels where additional contact points are needed without changing the starter
  • Supporting simple permissive circuits (e.g., enabling downstream control only when the starter is engaged) in machinery control wiring
  • Creating additional monitoring points for fault-finding and commissioning by offering extra auxiliary contact terminals for test measurement
  • Standardising panel builds by using a consistent auxiliary contact block across multiple TeSys GV2/GV3 starter sizes for uniform wiring practices

This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.

Delivery

  • Logistic partners UPS, FedEx and DHL
  • International delivery available
  • Premium nine hour delivery service available to anywhere in Europe
  • Same day dispatch from group stock

Warranty

All parts new or reconditioned are covered by EU Automation 12 month warranty

Returns

No hassle returns policy

Dedicated customer support team

Trade Credit

We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.

Payment options

We accept Bank transfers and the following methods of payment:

All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.

Services

Sourcing your part

Global supplier of quality automation and control components

Service Exchange

Dispose of your old unit by exchanging it for a working part.

Repair

A comprehensive repair service for faulty equipment.

Customer reviews

5 out of 5 stars steve

Got hold of Sime for a Carrier card for…


Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime

3 weeks ago

5 out of 5 stars Daniel

Excellent customer service...


Alex Bailey is my main point of contact at EU Automation...he is extremely friendly, has exceptional customer service skills and always offers great pricing & lead times.

2 months ago

5 out of 5 stars Jerry Schrink

Tom Higgins provided amazing service


Tom Higgins provided great prompt service. I contacted Tom by phone and within 10 minutes there was a quote in my in box. WOW Thank you Tom and Thank you EU Automation!

2 months ago

5 out of 5 stars Paulo Pereira

Excellent service and communication…


Excellent service and communication from Alex Bailey. He truly goes above and beyond to ensure his clients are 100% satisfied. The entire process was seamless, and his attention to detail made a huge difference. Highly recommended for anyone looking for amazing service!

2 months ago

5 out of 5 stars Gary

Tom Higgins did a great job at getting…


Tom Higgins did a great job at getting us the part we needed. He saw a concern with the part a verified before shipping.

3 months ago

5 out of 5 stars Lessle Smith

Thomas Higgins has gone above and…


Thomas Higgins has gone above and beyond to make things happen for my facility. His customer service and knowledge were an asset in helping me with my order and the logistics challenges!

4 months ago

Factory worker carrying automation parts box.

Our world, made possible by manufacturing. Manufacturing made possible by EU Automation.

Discover how we do our part to keep your production lines moving.

FAQs

View all FAQs

We're here when you need us