steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | CS1W-MD262 |
| Alternative Part Number | CS1WMD262 |
| Manufacturer | Omron |
| Category | PLC Systems |
| Input/Output Configuration | 32-way input / 32 outputs PNP |
| Rated Voltage | 30 VDC |
| Rated Current | I/O unit signal line: 0.5 A, I/O unit common line: 4 A, Power supply line: 7 A |
| Applicable Wire | Stranded wire, solid wire 0.08 to 1.5 mm² (AWG 28 to 16) |
| Ferrules | With insulation sleeve: 0.14 to 0.5 mm² (AWG 26 to 20), Without insulation sleeve: 0.75 to 1.5 mm² (AWG 18 to 16) |
| Mounting Method | Vertical or horizontal mounting options available |
| Connection Type | MIL 40 poles |
| PCB Colour | Green for input models, Blue for output models |
| Dimensions | When installed vertically: 52.7 x 124 x 40.8 mm, When installed horizontally: 124 x 52.7 x 40.8 mm for input models, When installed vertically: 39 x 124 x 40.8 mm, When installed horizontally: 124 x 39 x 40.8 mm for output models |
| Operating Temperature Range | -20 to +75°C (with no condensation or icing) |
| Operating Humidity Range | 5 to 95% RH (with no condensation) |
| Insulation Resistance | 100 MΩ min. (at 500 VDC) |
| Withstand Voltage | 500 VAC for 1 min (leakage current: 1 mA max.) |
| Insertion Durability | 50 times |
| Vibration Resistance | 10 to 150 Hz, acceleration of 50 m/s² for 80 min each in X, Y, and Z directions |
| Shock Resistance | 500 m/s² for 11 ms each in 6 directions 5 times |
| Storage Temperature Range | -20 to +75°C (with no condensation or icing) |
| Storage Humidity Range | 5 to 95% RH (with no condensation) |
The Omron CS1W-MD262 supports 32 PNP inputs and 32 PNP outputs.
Yes, the Omron CS1W-MD262 is designed to be compatible with various PLC systems. It's important to check the specific PLC compatibility to ensure proper operation.
Wiring the Omron CS1W-MD262 should be done with the power supply turned off to avoid electrical shock. Use the recommended ferrules and crimp tools for secure connections. Detailed wiring instructions can be found in the product's datasheet.
The rated voltage for the Omron CS1W-MD262 is 30 VDC, and the rated current is 0.5 A for I/O unit signal lines, 4 A for I/O unit common lines, and 7 A for the power supply line.
For the Omron CS1W-MD262, you should use stranded or solid wire ranging from 0.08 to 1.5 mm² (AWG 28 to 16). Ferrules with insulation sleeves are recommended for wire sizes 0.14 to 0.5 mm² (AWG 26 to 20), and without insulation sleeves for wire sizes 0.75 to 1.5 mm² (AWG 18 to 16).
The Omron CS1W-MD262 can be mounted to a DIN track either vertically or horizontally. Ensure to hook the fixed tab first and then push the terminal block onto the DIN track. For removal, press the case upward and pull the fixed tab side forward.
When using the Omron CS1W-MD262, ensure that it is not exposed to toxic gases, high temperatures, humidity, severe vibrations, or direct sunlight. It should also not be submerged in oil or water or be subject to oil or water splashes.
Yes, the Omron CS1W-MD262 can be mounted either vertically or horizontally, depending on your control panel layout and space requirements.
If you face difficulties wiring the Omron CS1W-MD262, refer to the datasheet for detailed wiring instructions and diagrams. Ensure that you are using the correct tools and that the power supply is turned off before wiring.
The Omron CS1W-MD262 is not designed for outdoor use and should be installed in a controlled indoor environment to prevent exposure to harsh conditions that could affect its functionality.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.