What type of power supply does the RH1-TP require?
The RH1-TP requires a 24 V DC power supply with a voltage range of -25% to +30%.
Can the RH1-TP be used in hazardous locations?
Yes, the RH1-TP is designed for use in hazardous locations and has pending approvals for ISA 12.12.01 Class 1 Div. 2.
What are the operating and storage temperature ranges for the RH1-TP?
The operating temperature range for the RH1-TP is 0 ºC to +60 ºC, and the storage temperature range is -25 ºC to +70 ºC.
What type of network connections does the RH1-TP support?
The RH1-TP supports 4 x 10BASE-T Ethernet connections using TP cable with RJ45 sockets.
What is the maximum current consumption of the RH1-TP at 24 V DC?
The maximum current consumption of the RH1-TP at 24 V DC is approximately 130 mA.
What is the Mean Time Between Failures (MTBF) for the RH1-TP?
The Mean Time Between Failures (MTBF) for the RH1-TP is calculated at 159.7 years, according to MIL-HDBK 217F at 25 ºC.
What type of diagnostics does the RH1-TP offer?
The RH1-TP offers diagnostic LEDs for power, data, and link status, as well as a signal contact for fault relay.
Does the RH1-TP have any redundancy features?
Yes, the RH1-TP features redundant 24 V power supply inputs to ensure continuous operation.
What are the dimensions and weight of the RH1-TP?
The dimensions of the RH1-TP are 40 mm x 125 mm x 80 mm (W x H x D), and it weighs approximately 530 g.
What is the protection class of the RH1-TP?
The RH1-TP has a protection class of IP 30.
How is the RH1-TP mounted for use?
The RH1-TP is designed to be mounted on a standard DIN Rail 35 mm.