steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | A9C20162 |
| Manufacturer | Schneider Electric |
| Range | Acti9 |
| Product Name | Acti9 iCT |
| Product Type | Modular contactor |
| Device Short Name | iCT |
| Part Description | Acti9 iCT modular contactor designed for remote switching of electrical loads such as lighting, heating and motors in residential and small commercial installations, offering a compact DIN-rail format and clear local status indication. |
| Poles | 2P |
| Contact Configuration | 2 NO (2 normally open) |
| Control Type | Remote control |
| Control Circuit Voltage (Uc) | 24 V AC, 50 Hz |
| Network Type | AC |
| Network Frequency | 50 Hz |
| Rated Operational Voltage (Ue) | 250 V AC, 50 Hz |
| Rated Operational Current (Ie) | 63 A (AC-7A); 20 A (AC-7B) |
| Maximum Power (Device Loss) | 1.6 W at 250 V AC |
| Rated Insulation Voltage (Ui) | 500 V AC (50/60 Hz) |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Control Signal Type | Maintained |
| Switching Frequency | 100 switching operations/day |
| Local Signalling | Action indicator |
| Hold-in Power Consumption | 4.6 VA |
| Inrush Power | 34 VA |
| Mounting Mode | Clip-on |
| Mounting Support | 35 mm symmetrical DIN rail |
| Width | 36 mm (4 × 9 mm pitches) |
| Height | 85 mm |
| Depth | 68.5 mm |
| Colour | White |
| Mechanical Durability | 1,000,000 cycles |
| Electrical Durability (IEC/EN 61095) | 100,000 cycles (63 A, AC-7A, 50 Hz); 30,000 cycles (20 A, AC-7B, 50 Hz); 30,000 cycles (AC-7C, 50 Hz) |
| Electrical Durability (EN/IEC 60947-4-1) | 100,000 cycles (AC-1, 50 Hz); 30,000 cycles (AC-3/AC-5a/AC-5b, 50 Hz) |
| Terminal Type (Control Circuit) | Tunnel type terminals |
| Control Wiring Capacity | 2 × 1.5 mm² rigid; 1 × 1.5…2.5 mm² rigid; 2 × 1.5…2.5 mm² flexible |
| Terminal Type (Power Circuit) | Tunnel type terminals |
| Power Wiring Capacity | 1 × 6…25 mm² rigid; 1 × 6…16 mm² flexible |
| Tightening Torque | Control circuit: 0.8 N·m; Power circuit: 3.5 N·m |
| Standards | IEC/EN 61095 |
| IP Rating | IP20 (per IEC 60529); IP40 when installed in modular enclosure |
| Noise Level | 30 dB |
| Heat Dissipation | 1.6 W at 50/60 Hz |
| Pollution Degree | 2 |
| Relative Humidity | 95% at 55 °C |
| Operating Altitude | Up to 2000 m |
| Operating Temperature | -5…60 °C |
| Storage Temperature | -40…70 °C |
| Product Compatibility | IACTc, IACTs, IATEt, IACTp |
| Market Segment | Residential; Small commercial |
It is a modular contactor designed for remote switching of electrical loads such as motors, heating circuits and lighting circuits. It provides electrically operated switching in a DIN-rail format for distribution boards and control panels.
It is a 2-pole device with 2 normally open (2 NO) power contacts, suitable for switching a two-wire circuit or two separate circuits depending on the installation design.
The control circuit is 24 V AC at 50 Hz. Ensure the control supply matches this rating to achieve reliable pull-in and hold-in operation.
The rated operational current is 63 A for AC-7A (resistive and slightly inductive loads) and 20 A for AC-7B (motor and more inductive loads). Always size according to the relevant utilisation category for the load.
The rated operational voltage is 250 V AC at 50 Hz for the switched (power) circuit.
It clips onto a 35 mm symmetrical DIN rail and occupies 4 modules (4 x 9 mm pitches), making it suitable for standard modular enclosures and distribution boards.
Approximate dimensions are 85 mm (height) x 36 mm (width) x 68.5 mm (depth). These values help with spacing and enclosure layout.
Yes. It includes a local action indicator to show the operating state, which can help during commissioning and routine checks.
It is specified for up to 100 switching operations per day, which suits many building-services and light industrial control duties.
It has a rated insulation voltage (Ui) of 500 V AC and a rated impulse withstand voltage (Uimp) of 4 kV, supporting use in typical low-voltage distribution environments.
Typical coil figures are 34 VA inrush and 4.6 VA hold-in. These values are useful when sizing control transformers and upstream control devices.
It uses tunnel-type terminals. The power circuit typically accepts 6–25 mm² rigid conductors or 6–16 mm² flexible conductors (single conductor per terminal). The control circuit typically accepts 1.5–2.5 mm² conductors (up to two conductors depending on type).
Recommended tightening torque is 3.5 N·m for the power terminals and 0.8 N·m for the control terminals to help maintain secure connections.
It is rated IP20 as a device and typically reaches IP40 when installed in a suitable modular enclosure. It is specified for operation from -5 to +60 °C, storage from -40 to +70 °C, and up to 2000 m altitude.
It is specified to IEC/EN 61095, a common standard for electromechanical contactors for household and similar purposes.
It is stated as EU RoHS compliant and mercury-free. In listings and documentation it may be referenced as a Green Premium product; the specific unit is commonly identified as Schneider A9C20162.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.