steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | 60127 |
| Product Range | Multi9 C60 |
| Device Short Name | C60 UL489 |
| Product Type | Miniature circuit breaker |
| Application | Electrical distribution circuits |
| Poles | 1P |
| Protected Poles | 1 |
| Rated Current | 10 A at 25 °C |
| Network Type | AC and DC |
| Rated Operational Voltage | 120 V AC, 240 V AC, and 60 V DC |
| Network Frequency | 50/60 Hz |
| Trip Unit Technology | Thermal-magnetic |
| Curve Code | D curve |
| Magnetic Tripping Limit | 12 x In ±20% for AC; 17 x In ±20% for DC |
| Breaking Capacity | 10 kA AIR at 120 V AC to UL 489; 5 kA AIR at 240 V AC to UL 489; 10 kA AIR at 60 V DC to UL 489 |
| IEC Breaking Capacity | 10 kA Icu at 240 V AC and 60 V DC to EN/IEC 60947-2 |
| Suitability for Isolation | Yes, according to EN/IEC 60947-2 |
| Rated Insulation Voltage | 500 V AC |
| Rated Impulse Withstand Voltage | 6 kV |
| Limitation Class | Class 3 |
| Control Type | Toggle handle |
| Local Indication | ON/OFF indication with contact position indicator |
| Mounting Mode | Clip-on fixed mounting |
| Mounting Support | 35 mm DIN rail |
| Width | 18 mm |
| Height | 107 mm |
| Depth | 73 mm |
| 9 mm Modules | 2 |
| Colour | Grey |
| Net Weight | 0.11 kg |
| Terminal Type | Tunnel type terminals, top or bottom connection |
| Compatible Conductor Size | 2.5 to 25 mm² rigid conductors, AWG 14 to AWG 4 |
| Wire Stripping Length | 14 mm |
| Tightening Torque | 2.5 N.m |
| Mechanical Durability | 20,000 cycles |
| Electrical Durability | 10,000 cycles |
| Padlocking Provision | Padlockable |
| IP Rating | IP20; IP40 when installed in a modular enclosure |
| Standards | EN/IEC 60947-2, UL 489, CSA C22.2 No. 5, GB 14048.2 |
| Certifications | UL, CSA, IEC, CCC |
| Pollution Degree | 3 |
| Overvoltage Category | IV |
| Operating Temperature | -30 °C to 70 °C |
| Storage Temperature | -40 °C to 80 °C |
| Relative Humidity | 95% at 55 °C |
| Operating Altitude | Up to 2000 m |
| Package Quantity | 1 unit |
| GTIN | 00785901210139 |
It is a miniature circuit-breaker designed for distribution applications. Schneider 60127 is part of the Multi9 C60 range and uses a thermal-magnetic trip unit to help protect circuits against overloads and short-circuit conditions.
This model is a 1-pole miniature circuit-breaker with one protected pole, making it suitable for single-pole circuit protection arrangements.
The rated current is 10 A at 25 °C, which means it is intended for circuits where a 10 ampere protective rating is required.
It uses a D curve. D curve breakers are typically selected where higher inrush currents may be present, such as some inductive or transformer-based loads, provided the overall installation design is suitable.
The breaking capacity depends on the voltage and standard being applied. It is rated at 10 kA AIR at 120 V AC to UL 489, 5 kA AIR at 240 V AC to UL 489, and 10 kA Icu at 240 V AC to EN/IEC 60947-2.
Yes. The datasheet lists AC and DC network compatibility, with rated operational voltages including 120 V AC, 240 V AC and 60 V DC.
This circuit-breaker is designed for clip-on mounting to a DIN rail, making it suitable for standard modular electrical panel layouts.
The unit measures approximately 107 mm high, 18 mm wide and 73 mm deep. It occupies two 9 mm modular pitches.
It uses tunnel-type terminals for top or bottom connection. The listed conductor range is 2.5 to 25 mm², equivalent to approximately AWG 14 to AWG 4 for rigid conductors.
The specified terminal tightening torque is 2.5 N.m, or 22.13 lbf.in, for top or bottom connections.
Yes. It has a contact position indicator and ON/OFF local signalling, helping users identify the breaker state from the front of the device.
Yes. Schneider 60127 is listed as suitable for isolation in accordance with EN/IEC 60947-2.
The listed standards include EN/IEC 60947-2, UL 489, CSA C22.2 No. 5 and GB 14048.2. Product certifications listed include UL, CSA, IEC and CCC.
The operating ambient temperature range is -30 °C to 70 °C. The storage temperature range is -40 °C to 80 °C.
The device is rated IP20 on its own in accordance with IEC 60529, and IP40 when installed in a suitable modular enclosure.
The listed mechanical durability is 20,000 cycles, and the listed electrical durability is 10,000 cycles.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.