Schneider Electric 33752 is a standard carriage switch (test position contact) designed for drawout circuit breaker installations, providing reliable position indication when the chassis is in the test position (CT). It features one changeover contact (1 NO/NC) for monitoring and signalling to control circuits, making it suitable for status indication, interlocking and remote monitoring within switchboards. Compatible with MasterPact NT, MasterPact NW (including NW DC) and ComPacT NS630b…1600 ranges, it supports AC-12 duties up to 6 A at 690 V AC and up to 8 A at 240/380/480 V AC, with DC-12 ratings up to 2.5 A at 24/48 V DC, and a minimum load of 100 mA at 24 V.
Specification Description
Manufacturer Schneider Electric
Part Number 33752
Product Type Auxiliary contact (carriage switch / test position contact)
Overview Standard carriage switch designed to provide status indication when a compatible drawout circuit breaker chassis is in the test position (CT).
Device Application Monitoring (test position indication for drawout installation)
Contact Configuration 1 changeover contact (1 NO/NC)
Auxiliary Contacts Type Standard
Auxiliary Contacts Operation Test position (CT)
Mounting Mode Drawout
Range Compatibility MasterPact NT; MasterPact NW; MasterPact NW DC; ComPacT NS630b…1600
Rated Operational Current (AC-12) 6 A at 690 V AC (50/60 Hz); 8 A at 240 V AC (50/60 Hz); 8 A at 380 V AC (50/60 Hz); 8 A at 480 V AC (50/60 Hz)
Rated Operational Current (DC-12) 2.5 A at 24/48 V DC; 0.8 A at 125 V DC; 0.3 A at 150 V DC
Minimum Load 100 mA at 24 V
Unit of Sale 1 piece
Package Dimensions (H × W × L) 0.9 cm × 4.2 cm × 4.2 cm
Package Weight 1.018 kg
REACh (SVHC) Free of SVHC (declared)
EU RoHS Pro-active compliance (outside EU RoHS legal scope)
Mercury Content Mercury free
Toxic Heavy Metals Toxic heavy metal free
Sustainable Packaging Yes
Circularity Profile No need for specific recycling operations
Take-back No

What does this carriage switch do in a drawout circuit breaker installation?

It provides an auxiliary indication signal when the breaker carriage is in the chassis test position (CT). This allows control circuits, PLC inputs, or panel indicators to monitor the mechanical position of the drawout device.

Which breaker ranges is this switch designed to work with?

It is designed for Schneider Electric drawout systems including MasterPact NT, MasterPact NW (including NW DC), and ComPacT NS630b to NS1600 drawout applications.

What is meant by the chassis test position (CT)?

The chassis test position is a defined mechanical position of a drawout breaker where position signalling is available via the carriage switch. It is used for position monitoring and control logic based on the drawout status.

What contact configuration does the switch provide?

It provides one changeover contact (1 NO/1 NC), enabling either normally-open or normally-closed signalling depending on how you wire the control circuit.

Is this intended for monitoring or for switching power loads?

It is intended for monitoring and signalling (auxiliary circuit use). It is rated under utilisation categories such as AC-12 and DC-12, which are typical for control and indication circuits rather than power switching.

What are the key electrical ratings for typical control voltages?

Typical ratings include AC-12 up to 8 A at 240/380/480 V AC (and 6 A at 690 V AC), and DC-12 ratings such as 2.5 A at 24/48 V DC and 0.8 A at 125 V DC. These values help size the signalling circuit and protective devices appropriately.

Is there a minimum load requirement for reliable operation?

Yes. The minimum load is 100 mA at 24 V, which is useful to consider when driving very low-power inputs to ensure dependable contact performance.

Where is the switch mounted in the system?

It is a drawout-mounted auxiliary contact used as a carriage switch for the chassis, actuated by the mechanical movement of the breaker within the drawout mechanism.

Can it be used to distinguish between different drawout positions?

It is specifically associated with the test position (CT). If you need separate signalling for other positions (for example, connected or disconnected), that typically requires additional dedicated position contacts.

Does it meet common environmental compliance expectations for EU installations?

It is declared REACh compliant (including being free of SVHC as declared) and is aligned with EU RoHS expectations as stated for the product family, supporting common compliance needs for panel builds in the UK and EU.

Are there any regulatory chemical disclosures that may be relevant for exports?

The product information includes a California Proposition 65 chemical warning disclosure. This may be relevant when preparing documentation for exports where such declarations are requested.

How is this item commonly referenced in control schematics?

It is commonly shown as a position-operated auxiliary contact associated with the breaker carriage test position, using a changeover contact symbol (NO/NC) and labelled to indicate CT or test-position status. In documentation it may be referenced by its Schneider designation, such as 33752, in the bill of materials.

  • Monitoring when a drawout circuit breaker chassis is in the test position within low-voltage switchgear
  • Providing a status signal to control panels to indicate the breaker carriage position for operational interlocking
  • Feeding BMS/SCADA/PLC inputs with a dedicated test-position confirmation contact for remote indication
  • Enabling sequencing and permissive logic for switching procedures that require confirmation of the test position before actions proceed
  • Supporting maintenance and commissioning workflows by giving clear electrical indication of the chassis test position during functional checks
  • Integrating with alarm and indication circuits (lamps, relays, input modules) to flag when equipment is in the test position
  • Improving operational visibility in electrical distribution boards by differentiating between connected, test, and withdrawn positions (where configured)
  • Adding auxiliary signalling to MasterPact NT/NW and ComPacT NS drawout installations where a changeover contact is required

This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.

Delivery

  • Logistic partners UPS, FedEx and DHL
  • International delivery available
  • Premium nine hour delivery service available to anywhere in Europe
  • Same day dispatch from group stock

Warranty

All parts new or reconditioned are covered by EU Automation 12 month warranty

Returns

No hassle returns policy

Dedicated customer support team

Trade Credit

We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.

Payment options

We accept Bank transfers and the following methods of payment:

All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.

Services

Sourcing your part

Global supplier of quality automation and control components

Service Exchange

Dispose of your old unit by exchanging it for a working part.

Repair

A comprehensive repair service for faulty equipment.

Customer reviews

5 out of 5 stars steve

Got hold of Sime for a Carrier card for…


Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime

3 months ago

5 out of 5 stars Daniel

Excellent customer service...


Alex Bailey is my main point of contact at EU Automation...he is extremely friendly, has exceptional customer service skills and always offers great pricing & lead times.

4 months ago

5 out of 5 stars Jerry Schrink

Tom Higgins provided amazing service


Tom Higgins provided great prompt service. I contacted Tom by phone and within 10 minutes there was a quote in my in box. WOW Thank you Tom and Thank you EU Automation!

5 months ago

5 out of 5 stars Paulo Pereira

Excellent service and communication…


Excellent service and communication from Alex Bailey. He truly goes above and beyond to ensure his clients are 100% satisfied. The entire process was seamless, and his attention to detail made a huge difference. Highly recommended for anyone looking for amazing service!

5 months ago

5 out of 5 stars Gary

Tom Higgins did a great job at getting…


Tom Higgins did a great job at getting us the part we needed. He saw a concern with the part a verified before shipping.

5 months ago

5 out of 5 stars Lessle Smith

Thomas Higgins has gone above and…


Thomas Higgins has gone above and beyond to make things happen for my facility. His customer service and knowledge were an asset in helping me with my order and the logistics challenges!

6 months ago

Factory worker carrying automation parts box.

Our world, made possible by manufacturing. Manufacturing made possible by EU Automation.

Discover how we do our part to keep your production lines moving.

FAQs

View all FAQs

We're here when you need us