steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | GV2LE22 |
| Manufacturer | Schneider |
| Product Type | Motor Circuit Breaker |
| Application | Motor Protection |
| Trip Unit Technology | Magnetic |
| Poles Description | 3P (3 Poles) |
| Network Type | AC |
| Utilisation Category | AC-3 conforming to IEC 60947-4-1, Category A conforming to IEC 60947-2 |
| Network Frequency | 50/60 Hz conforming to IEC 60947-2 |
| Fixing Mode | Clipped on 35 mm symmetrical DIN rail, Screwed on panel (with adaptor plate) |
| Operating Position | Any Position |
| Motor Power kW | 9 kW at 400/415 V AC 50/60 Hz, 11 kW at 500 V AC 50/60 Hz, 15 kW at 500 V AC 50/60 Hz, 18.5 kW at 690 V AC 50/60 Hz |
| Breaking Capacity | 50 kA Icu at 230/240 V AC 50/60 Hz, 15 kA Icu at 400/415 V AC 50/60 Hz, 6 kA Icu at 440 V AC 50/60 Hz, 4 kA Icu at 500 V AC 50/60 Hz, 3 kA Icu at 690 V AC 50/60 Hz |
| Rated Service Short-Circuit Breaking Capacity | 100% at 230/240 V AC 50/60 Hz, 75% at 500 V AC 50/60 Hz, 75% at 690 V AC 50/60 Hz, 50% at 440 V AC 50/60 Hz, 40% at 400/415 V AC 50/60 Hz |
| Control Type | Toggle |
| Rated Current (In) | 25 A |
| Magnetic Tripping Current | 327 A |
| Conventional Free Air Thermal Current (Ith) | 25 A conforming to IEC 60947-4-1 |
| Rated Operational Voltage (Ue) | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Rated Insulation Voltage (Ui) | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV conforming to IEC 60947-2 |
| Suitability for Isolation | Yes conforming to IEC 60947-1 § 7-1-6 |
| Power Dissipation per Pole | 1.8 W |
| Mechanical Durability | 100000 cycles |
| Electrical Durability | 100000 cycles for AC-3 at 415 V |
| Maximum Operating Rate | 40 cyc/h |
| Rated Duty | Continuous conforming to IEC 60947-4-1 |
| Tightening Torque | 1.7 N.m on screw clamp terminals |
| Width | 45 mm |
| Height | 89 mm |
| Depth | 78.5 mm |
| Net Weight | 0.33 kg |
| Colour | Dark grey |
| Standards | EN/IEC 60947-2, UL 60947-4-1 |
| Product Certifications | CCC, UL, EAC, BV, RINA, UKCA |
| IK Degree of Protection | IK04 |
| IP Degree of Protection | IP20 conforming to IEC 60529 |
| Climatic Withstand | Conforming to IACS E10 |
| Ambient Air Temperature for Storage | -40…80 °C |
| Fire Resistance | 960 °C conforming to IEC 60695-2-11 |
| Ambient Air Temperature for Operation | -20…60 °C |
| Mechanical Robustness | Shocks: 30 Gn, Vibrations: 5 Gn, 5...150 Hz |
| Operating Altitude | 2000 m |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Compliant |
| EU RoHS Declaration | Mercury free |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | End Of Life Information |
| WEEE | Must be disposed on European Union markets following specific waste collection |
The motor protection switch is designed to provide protection for electric motors from overloads and short circuits, ensuring safe operation and preventing damage to the motor.
Yes, the GV2LE22 is suitable for isolation according to IEC 60947-1 § 7-1-6, allowing it to be used to ensure a circuit is completely de-energised for service or maintenance.
The device can be mounted on a 35 mm symmetrical DIN rail with a clip-on mechanism or screwed onto a panel with an adaptor plate, providing flexibility for different installation requirements.
The rated operational voltage (Ue) for this motor protection switch is 690 V AC 50/60 Hz, conforming to IEC 60947-2 standards.
The rated current (In) for the GV2LE22 is 25 A, which is the maximum continuous current the device can carry under specified conditions.
The breaking capacity varies depending on the voltage, with a maximum of 50 kA Icu at 230/240 V AC 50/60 Hz and a minimum of 3 kA Icu at 690 V AC 50/60 Hz, conforming to IEC 60947-2.
The GV2LE22 is equipped with screw clamp terminals, which provide a secure and reliable connection for the wiring.
The device has an IP20 degree of protection conforming to IEC 60529, which offers protection against solid objects larger than 12.5 mm but not against water.
The conventional free air thermal current (Ith) rating for this device is 25 A, conforming to IEC 60947-4-1.
The GV2LE22 has dimensions of 45 mm in width, 89 mm in height, and 78.5 mm in depth, with a net weight of 0.33 kg.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.