steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider |
| Part Number | BMXDRC0805 |
| Product Type | Relay discrete output module |
| Range | Modicon X80 |
| Output Type | 8 relay outputs with normally open or normally closed contact configuration |
| Output Logic | Positive or negative |
| Discrete Output Number | 8 outputs conforming to EN/IEC 61131-2 |
| Output Voltage | 24 to 240 V AC / 24 to 125 V DC |
| Wider Output Voltage Range | 19 to 264 V AC / 5 to 150 V DC |
| Electrical Connection | 40-way terminal block |
| Network Frequency | 50/60 Hz |
| Frequency Limits | 47 to 63 Hz |
| Conventional Free Air Thermal Current | 4 A at 40 °C, 3 A at 50 °C, 2 A at 60 °C |
| Insulation Resistance | Greater than 10 MOhm at 500 V DC |
| Power Dissipation | 3.6 W |
| Output Response Time | Up to 10 ms activation and up to 13 ms deactivation |
| Typical Current Consumption | 40 mA at 3.3 V DC and 101 mA at 24 V DC |
| Minimum Switching Current | 10 mA at 5 V DC |
| Protection Requirements | External short-circuit, overload and overvoltage protection required |
| Overload Protection | Use one fast-blow fuse per channel or group of channels |
| Overvoltage Protection | Use a discharge diode on DC outputs, an RC circuit on AC outputs, or a ZNO surge limiter on AC outputs |
| Status Indicators | Green RUN LED, green channel diagnostic LEDs, red ERR LED and red I/O LED |
| Dielectric Strength | 1780 V AC at 50/60 Hz for 1 minute |
| IP Rating | IP20 |
| Vibration Resistance | 3 gn |
| Shock Resistance | 30 gn |
| Relative Humidity | 0 to 95% without condensation |
| Operating Temperature Range | 0 to 60 °C |
| Operating Altitude | 0 to 2000 m, with derating from 2000 to 5000 m |
| Net Weight | 0.189 kg |
| GTIN | 3606489485061 |
| Country of Origin | France |
| Commodity Code | 853890 |
| Product Description | The Schneider BMXDRC0805 is a Modicon X80 relay discrete output module designed for industrial automation systems requiring eight isolated relay output channels. It provides flexible AC and DC switching capability, diagnostic LED indication and terminal block connectivity for integration into compatible control assemblies. |
This is a relay discrete output module from the Modicon X80 range. It is designed to provide 8 relay output channels for controlling field devices in industrial automation systems.
The module provides 8 discrete relay outputs, conforming to EN/IEC 61131-2.
The outputs are relay contacts that can be used as normally open or normally closed outputs, giving flexibility for different control circuit designs.
The BMXDRC0805 can handle DC output voltages from 5 to 125 V, with a broader stated DC range of 5 to 150 V. For AC applications, it is rated for 24 to 240 V, with limits from 19 to 264 V AC.
The module uses a 40-way terminal block connection for wiring the output channels and associated field circuits.
The output response time is up to 10 ms for activation and up to 13 ms for deactivation.
Typical current consumption is 40 mA at 3.3 V DC and 101 mA at 24 V DC.
The conventional free air thermal current is rated at 4 A at 40 °C, 3 A at 50 °C, and 2 A at 60 °C.
External protection is required. The datasheet specifies fast-blow fuse protection per channel or group of channels for overload and short-circuit protection. For overvoltage protection, a discharge diode is recommended for DC loads, while an RC circuit or ZNO surge limiter may be used for AC loads.
The minimum switching current is 10 mA at 5 V DC, which is important when checking compatibility with low-current loads.
The module includes a green RUN LED, one green channel diagnostic LED per output, a red ERR LED, and a red I/O LED.
The module has an IP20 degree of protection. It is rated for operation at 0 to 60 °C with 0 to 95% relative humidity, without condensation.
The dielectric strength is rated at 1780 V AC at 50/60 Hz for 1 minute.
The module is rated for 3 gn vibration resistance and 30 gn shock resistance, making it suitable for typical industrial cabinet environments.
The module is rated for operation from 0 to 2000 m. It can also be used from 2000 to 5000 m when the appropriate derating factor is applied.
The module weighs approximately 0.189 kg.
The GTIN listed for the BMXDRC0805 is 3606489485061.
It is typically used to switch external pre-actuators or field loads such as relays, contactors, indicator circuits, valves, or other discrete control devices within the module’s rated electrical limits.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.