What is this module used for?
It is a PNOZ X3 series safety relay designed for monitoring emergency stop circuits and safety gate/limit switch applications, providing multiple relay outputs for switching control circuits.
What supply voltages does it accept?
It is designed for a 110 V AC supply and also supports 24 V DC as a second supply voltage option (depending on how it is applied).
How many output contacts are available?
It provides 3 instantaneous safety N/O contacts, 1 auxiliary N/C contact, and 1 semiconductor output.
Does it support single-channel and dual-channel input wiring?
Yes. It supports single-channel and dual-channel wiring and can be configured with or without detection of shorts across contacts.
What start/reset modes are supported?
It supports automatic reset and monitored manual reset, allowing you to match the start behaviour to the machine’s risk assessment and control scheme.
What are the contact ratings for typical control duty?
For AC-15 duty, the maximum current is 5.0 A. For DC-13 duty (6 cycles/min), the maximum current is 6.0 A.
What are the physical dimensions?
The unit measures 45 mm (W) × 87 mm (H) × 121 mm (D), making it suitable for space-conscious control cabinet layouts.
What temperature range can it operate in?
The specified ambient operating temperature range is -20 °C to +55 °C.
What terminal type does it use?
It uses integrated screw terminals (fixed terminal style), which are commonly chosen for robust field wiring in control panels.
Which standards and certifications does it reference?
It references EN 60947-5-1 and is associated with common machinery safety standards such as EN 60204-1, EN 62061, and EN ISO 13849-1. It also carries certifications/approvals including CE, cULus Listed, TÜV, EAC, CCC, KOSHA and others (approval requirements should be confirmed for your installation region).
Is there an optional protective cover available?
Yes. An optional accessory cover is available: COVER P-93 (accessory number 774090), which may be used to help protect the terminals depending on the enclosure design.
How can I confirm I’m selecting the correct variant for my panel?
Check the required supply voltage (110 V AC / 24 V DC option), the needed number of N/O and N/C contacts (3 N/O + 1 N/C plus 1 semiconductor output), the reset mode (automatic or monitored manual), and the installation space (45 × 87 × 121 mm). If you need to reference it internally, the variant is commonly identified as Pilz 774314.