steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LC1D115BD |
| Manufacturer | Schneider Electric |
| Product Type | Contactor |
| Utilisation Category | AC-1, AC-3, AC-4 |
| Poles Description | 3P (3 NO) |
| Rated Operational Voltage | Power circuit: ≤ 1000 V AC 25...400 Hz, Power circuit: ≤ 300 V DC |
| Rated Operational Current | 200 A (at <60°C) at ≤ 440 V AC AC-1 for power circuit, 115 A (at <60°C) at ≤ 440 V AC AC-3 for power circuit |
| Motor Power kW (AC-3) | 30 kW at 220...230 V AC 50/60 Hz, 55 kW at 380...400 V AC 50/60 Hz, 59 kW at 415...440 V AC 50/60 Hz, 75 kW at 500 V AC 50/60 Hz, 80 kW at 660...690 V AC 50/60 Hz, 65 kW at 1000 V AC 50/60 Hz |
| Motor Power HP (UL/CSA) | 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors, 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
| Control Circuit Type | DC standard |
| Control Circuit Voltage | 24 V DC |
| Auxiliary Contact Composition | 1 NO + 1 NC |
| Rated Impulse Withstand Voltage | 8 kV conforming to IEC 60947 |
| Overvoltage Category | III |
| Conventional Free Air Thermal Current | 200 A (at 60°C) for power circuit |
| Rated Making Capacity | 1260 A at 440 V for power circuit conforming to IEC 60947 |
| Rated Breaking Capacity | 1100 A at 440 V for power circuit conforming to IEC 60947 |
| Rated Short-time Withstand Current | 250 A 40°C - 10 min, 550 A 40°C - 1 min, 950 A 40°C - 10 s, 1100 A 40°C - 1 s for power circuit |
| Associated Fuse Rating | 250 A gG at ≤ 690 V coordination type 1, 200 A gG at ≤ 690 V coordination type 2 for power circuit |
| Average Impedance | 0.6 mOhm - Ith 200 A 50 Hz for power circuit |
| Rated Insulation Voltage | Power circuit: 600 V CSA certified, Power circuit: 600 V UL certified, Power circuit: 1000 V conforming to IEC 60947-4-1, Signalling circuit: 690 V conforming to IEC 60947-1, Signalling circuit: 600 V CSA certified, Signalling circuit: 600 V UL certified |
| Electrical Durability | 0.8 Mcycles 200 A AC-1 at Ue ≤ 440 V, 0.95 Mcycles 115 A AC-3 at Ue ≤ 440 V |
| Power Dissipation per Pole | 24 W AC-1, 7.9 W AC-3 |
| Standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 |
| Product Certifications | CCC, UL, BV, CSA, GL, GOST, DNV, LR, RINA |
| Connections - Terminals | Control circuit: screw clamp terminals, Power circuit: connector for cables |
| Tightening Torque | Control circuit: 1.2 N.m, Power circuit: 12 N.m |
| Operating Time | 20...35 ms closing, 40...75 ms opening |
| Mechanical Durability | 8 Mcycles |
| Maximum Operating Rate | 1200 cyc/h at 60°C |
| Coil Technology | With integral suppression device |
| Control Circuit Voltage Limits | Operational: 0.75...1.2 Uc DC at 55°C, Drop-out: 0.15...0.4 Uc DC at 55°C |
| Time Constant | 25 ms |
| Inrush Power | 270…365 W at 20°C |
| Hold-in Power Consumption | 2.4…5.1 W at 20°C |
| Signalling Circuit Frequency | 25...400 Hz |
| Minimum Switching Current | 5 mA for signalling circuit |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Non-overlap Time | 1.5 ms on de-energisation and energisation between NC and NO contact |
| Insulation Resistance | > 10 MOhm for signalling circuit |
| IP Degree of Protection | IP20 front face conforming to IEC 60529 |
| Protective Treatment | TH conforming to IEC 60068-2-30 |
| Pollution Degree | 3 |
| Ambient Air Temperature for Operation | -40…60°C, 60…70°C with derating |
| Ambient Air Temperature for Storage | -60…80°C |
| Operating Altitude | 0...3000 m without derating |
| Fire Resistance | 850°C conforming to IEC 60695-2-1 |
| Flame Retardance | V1 conforming to UL 94 |
| Mechanical Robustness | Vibrations: contactor open 2 Gn, 5...300 Hz, contactor closed 4 Gn, 5...300 Hz, Shocks: contactor closed 15 Gn for 11 ms, contactor open 6 Gn for 11 ms |
| Dimensions (Height x Width x Depth) | 158 mm x 120 mm x 136 mm |
| Net Weight | 2.5 kg |
The Schneider Electric contactor is designed for motor control and resistive load applications. It can be used in categories AC-1, AC-3, and AC-4, making it versatile for various industrial uses.
Yes, this contactor is rated for use with power circuits up to 300 V DC, making it suitable for direct current applications.
The contactor has a rated operational current of 200 A for AC-1 applications and 115 A for AC-3 applications at less than 60°C at <= 440 V AC for the power circuit.
The dimensions of the contactor are 158 mm in height, 120 mm in width, and 136 mm in depth.
The control circuit of the contactor operates with a standard 24 V DC coil voltage.
The contactor has an IP20 degree of protection for the front face, conforming to IEC 60529 standards.
The ambient operating temperature range for this contactor is from -40°C to 60°C, with derating required for temperatures between 60°C and 70°C.
The contactor is equipped with mechanically linked auxiliary contacts comprising 1 normally open (NO) and 1 normally closed (NC) contact.
The contactor is certified by multiple international standards, including CSA, EN, IEC, UL, and it also has certifications from CCC, BV, CSA, GL, GOST, DNV, LROS, and RINA.
The contactor can be mounted using a plate or rail support, providing flexibility for installation in various settings.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.