steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Festo |
| Part Number | CPX-FB33 |
| Alternative Part Number | CPXFB33 |
| Manufacturer Article Number | 548755 |
| Product Type | CPX bus node |
| Function | Connects a Festo CPX terminal to a PROFINET network for distributed input and output communication |
| Supported Protocols | PROFINET RT and PROFINET IRT |
| Data Transmission Rate | 100 Mbit/s |
| Fieldbus Interface | 2 × M12 × 1 sockets, 4-pin, D-coded |
| Nominal Operating Voltage | 24 V DC |
| Operating Voltage Range | 18–30 V DC |
| Typical Current Consumption | 120 mA |
| Maximum Input Address Capacity | 64 bytes |
| Maximum Output Address Capacity | 64 bytes |
| Configuration Controls | DIL switches |
| Diagnostic Features | Channel- and module-oriented diagnostics, diagnostic memory, module undervoltage monitoring and network status indication |
| Status Indicators | LEDs for network error, network activity, maintenance, parameterisation, load supply, electronics supply and system error |
| Additional Functions | Acyclic fieldbus and Ethernet data access, Fast Start-Up, failsafe response configuration, channel forcing and process-data system status |
| Protection Rating | IP65 and IP67 |
| Ambient Operating Temperature | -5 to +50 °C |
| Storage Temperature | -20 to +70 °C |
| Housing Material | Die-cast aluminium |
| Corrosion Resistance Class | CRC 0 |
| Dimensions | 50 × 107 × 50 mm, including interlinking block |
| Weight | 280 g |
| Commodity Code | 847330 |
The CPX-FB33 is a fieldbus node designed to connect a Festo CPX terminal to an industrial Ethernet network using PROFINET RT or PROFINET IRT.
It communicates using PROFINET RT and PROFINET IRT, with a data transmission rate of 100 Mbit/s.
The unit has two 4-pin, D-coded M12x1 sockets. The two-port arrangement allows it to be incorporated into suitable industrial Ethernet network topologies.
It has a nominal operating voltage of 24 V DC and an operating range of 18 to 30 V DC. Typical intrinsic current consumption is 120 mA.
The bus node provides channel- and module-oriented diagnostics, including module undervoltage monitoring and diagnostic memory. LEDs indicate network activity, network errors, system errors, power conditions and parameter status.
The maximum address volume is 64 bytes for inputs and 64 bytes for outputs.
Including the interlinking block, the unit measures approximately 50 mm wide, 107 mm long and 50 mm high.
The enclosure is rated IP65 and IP67 when correctly installed with suitable connections and sealing components.
The specified ambient operating temperature range is -5°C to 50°C. The storage temperature range is -20°C to 70°C.
The housing is manufactured from die-cast aluminium, providing a robust enclosure for industrial installations.
Local settings are made using integrated DIL switches. An optional memory card can also be fitted for compatible configuration requirements.
The CPX-FB33 provides acyclic data access through the fieldbus and Ethernet interfaces, Fast Start Up, channel-oriented diagnostics and representation of system status through process data.
Confirm the network protocol, connector type, address requirements, DIL-switch positions, power supply range and CPX terminal configuration. Matching these details helps ensure the replacement operates as intended.
Separate TP1 and TP2 indicators display network activity for ports 1 and 2. An NF indicator identifies a network fault condition.
The specified product weight is approximately 280 g.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.