steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 2CP100.60-1 |
| Alternative Part Number | 2CP100601 |
| Manufacturer | B&R |
| Series | CP100 |
| Interface Module Type | CPU Interface Module |
| Communication Interfaces | RS232, RS485, RS422 |
| Stand Alone | Yes |
| Supply Voltage | 270 V ac (maximal), 30 V dc (maximal) |
| Current | 3 A (max. load on contacts) |
| Command Cycle Time | 0.8 µs |
| Dual Ported RAM (DPR) | 128 KByte SRAM |
| System RAM | 256 KByte SRAM |
| Application Memory | Order separately (ME910 or ME913) |
| Real Time Clock | Nonvolatile, backup battery |
| RAM Buffering | Lithium Battery (in CPU) for at least 2 years |
| System Bus | Yes |
| Key Switch | Yes |
| Reset Button | Yes |
| Configuration Buttons | UP, DOWN, ENTER; programmable by user |
| Status Display | Alphanumeric LC Display (2 lines with 8 characters each), 6 Status LEDs |
| READY Relay | Normally open, 24 VDC / 230 VAC nominal, 30 VDC / 270 VAC maximal |
| FORCE Relay | Normally open, 24 VDC / 230 VAC nominal, 30 VDC / 270 VAC maximal |
| Power Consumption | Max. 10 W |
| Storage Temperature | -20 °C to +60 °C (with APM inserted incl. lithium battery) |
| Dimensions (H x W x D) | 285 mm x 80 mm x 185 mm |
| Base Plate Module | BP300 |
| B&R ID Code | $20 |
| Communication Processor Type | RISC |
| Commodity Code | 853710 |
The CPU Interface Module supports a variety of standard communication interfaces including RS232, RS485/RS422, and CAN, depending on the specific model. These interfaces allow for flexible connectivity options in industrial automation settings.
No, the CPU Interface Module is designed to be operated on the BP300 base plate module and requires two slots. It cannot be used on an expansion unit.
Yes, the real-time clock on the CPU Interface Module is nonvolatile and backed up by a battery, ensuring that timekeeping continues even during power outages.
For RS485/RS422 communication, the maximum cable length is 1200 meters, allowing for extensive reach in larger industrial environments.
The lithium battery can be changed by removing the battery cover, using the removal ribbon to pull the battery from the compartment, and then inserting a new battery with the correct polarity. It's recommended to change the battery when the module is not under power.
The CPU Interface Module has a nominal switching voltage of 24 VDC / 230 VAC and a maximum of 30 VDC / 270 VAC. It also has a maximum load on contacts of 3 A.
The READY relay is normally open and can be used for emergency stop functions, while the FORCE relay is also normally open and is linked to the 'FORCED' LED, indicating when a process variable has been overridden.
The application memory is not included with the CPU Interface Module and must be ordered separately. It can be configured using the programming system provided by B&R.
The CPU Interface Module can be stored with an application memory module inserted, including a lithium battery, at temperatures ranging from -20 °C to +60 °C.
Programming of the CPU Interface Module is carried out using the B&R programming system, which offers several programming languages such as AWL (instruction list), KOP (ladder diagram), and PL2000 (structured text).
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.