steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | NZM7-63N |
| Alternative Part Number | NZM763N |
| Manufacturer | Klockner-Moeller |
| Part Category | Circuit Protection |
| Part Family | Molded Case Circuit Breakers |
| Rated Operational Voltage Ue | 500 V AC |
| Rated Control Voltage Us | 110 – 415 V AC, 24 – 240 V DC |
| Conventional Thermal Current Ith | 6 A (AC), 4 A (DC) |
| Rated Operational Current Ie | Up to 63 A |
| Short-Circuit Protection | Max. fuse: 10 A, Max. miniature circuit-breaker: 10 A |
| Terminal Capacity | 1 or 2 conductors, solid or flexible: 0.75 – 2.5 mm², Flexible with ferrule: AWG 18 – 14 |
| Auxiliary Contacts | Available with different configurations |
| Voltage Releases | Shunt releases, undervoltage releases available |
| Operating Range | AC: 0.85 – 1.1xUs, DC: 0.85 – 1.1xUs |
| Lifespan, Mechanical | 20000 Operations |
| Maximum Operating Frequency | 20 Operations per hour |
| Commodity Code | 853649 |
A molded case circuit breaker, such as the NZM7-63N, is designed to protect electrical circuits from damage caused by overcurrents or short circuits. Its function is to interrupt current flow after a fault is detected, ensuring the safety and reliability of the electrical system.
Yes, the NZM7-63N is suitable for use in both AC and DC applications. It is designed to handle a variety of voltage levels, making it versatile for different electrical systems.
The settings for overload and short-circuit releases should be determined based on the specific requirements of your electrical system, taking into account the maximum current ratings and the level of protection needed. It is recommended to consult with an electrical engineer or refer to the technical specifications for guidance.
Yes, the NZM7-63N can be equipped with accessories such as shunt trips or undervoltage releases that allow for remote tripping of the breaker.
Frequent tripping of the circuit breaker may indicate an overloaded circuit, a short circuit, or a faulty breaker. It is important to investigate the cause of the tripping by checking the circuit for overloads, inspecting for any signs of damage or wear, and ensuring that the breaker is correctly rated for the circuit it is protecting.
Yes, the NZM7-63N can be used as a main switch for emergency stop functions when fitted with the appropriate accessories and when it meets the requirements of IEC/EN 60 204-1 for main switch characteristics.
Regular maintenance for the NZM7-63N includes visual inspections for any signs of damage or wear, testing the mechanical operation of the breaker, and ensuring that all connections are secure. It is also important to periodically verify the correct functioning of the trip mechanism.
Correct installation of the NZM7-63N involves following the manufacturer's installation guidelines, ensuring that the breaker is compatible with the electrical system, and that it is installed by a qualified electrician. Proper mounting, connection, and configuration are essential for safe operation.
Using a circuit breaker that is incorrectly rated for the electrical system can result in inadequate protection, which may lead to potential damage to the electrical system, increased risk of fire, or failure to trip in the event of an overcurrent or short circuit.
The NZM7-63N should be used within the environmental conditions specified by the manufacturer. This includes considerations for temperature, humidity, and exposure to corrosive substances. Using the breaker outside of these conditions can affect its performance and lifespan.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.