steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 6SL3210-1KE23-8AF1 |
| Alternative Part Number | 6SL32101KE238AF1 |
| Manufacturer | Siemens |
| Category | General Automation |
| Rated Power (IEC 400V LO) | 18.5 kW |
| Rated Power (IEC 400V HO) | 15 kW |
| Rated Voltage | 400 V ac (IEC), 480 V ac (NEC) |
| Input Phases | 3 AC |
| Line Voltage | 380 to 480 V ac +10% -20% |
| Line Frequency | 47 to 63 Hz |
| Rated Current (LO) | 48.20 A |
| Rated Current (HO) | 45.20 A |
| Max. Output Current | 62.00 A |
| Output Frequency (V/f Control) | 0 to 550 Hz |
| Output Frequency (Vector Control) | 0 to 240 Hz |
| Overload Capability (LO) | 150% base load current IL for 3 s, followed by 110% IL for 57 s in a 300 s cycle time |
| Overload Capability (HO) | 200% base load current IH for 3 s, followed by 150% IH for 57 s in a 300 s cycle time |
| Efficiency η | 0.97 |
| Power Factor λ | 0.70 to 0.85 |
| Sound Pressure Level | 66 dB |
| Power Loss | 0.50 kW |
| Cooling Method | Air cooling using an integrated fan |
| Installation Altitude | Up to 1000 m (3280.84 ft) |
| Ambient Operating Temperature | -10 to 40 °C (14 to 104 °F) |
| Relative Humidity | 95% at 40 °C (104 °F), non-condensing |
| Communication | PROFINET, EtherNet/IP |
| Integrated Filter Class | Class A |
| Degree of Protection | IP20 / UL open type |
| Dimensions (H x W x D) | 295 mm x 140 mm x 208 mm |
| Net Weight | 4.40 kg |
| Efficiency Class | IE2 according to IEC61800-9-2 |
The inverter drive operates with a 3-phase input at a line voltage of 380 to 480 V ac with a frequency range of 47 to 63 Hz. It delivers a 3-phase output with a rated voltage of 400 V ac IEC and 480 V NEC. The rated power is 18.5 kW for Low Overload (LO) and 15 kW for High Overload (HO), with corresponding rated currents of 37 A for LO and 31 A for HO.
Yes, it has an overload capability with 150% base load current for 3 seconds, followed by 110% for 57 seconds in a 300-second cycle for Low Overload (LO), and 200% base load current for 3 seconds, followed by 150% for 57 seconds in a 300-second cycle for High Overload (HO).
The inverter drive is designed to operate within an ambient temperature range of -10 to 40 °C for operation, with a maximum relative humidity of 95% at 40 °C, where condensation and icing are not permissible. It also has a cooling requirement of 0.018 m³/s and can be installed at altitudes up to 1000 meters without derating.
It utilises air cooling with an integrated fan to maintain optimal operating temperatures.
The inverter drive supports PROFINET and EtherNet/IP for seamless integration into networked control systems.
The inverter drive has a degree of protection rated at IP20 / UL open type, which means it is protected against solid objects larger than 12.5 mm but not against water.
The inverter drive has dimensions of 295 mm in height, 140 mm in width, and 225.4 mm in depth, with a net weight of approximately 4.40 kg.
It complies with international standards including UL, cUL, CE, and C-Tick (RCM), ensuring its suitability for various markets and applications.
The inverter drive is rated with an efficiency class of IE2, indicating a high level of energy efficiency during operation.
External devices can be connected via the inverter drive's interface which includes 6 digital inputs, 2 digital outputs, 1 analogue input, and 1 analogue output, along with a PTC/KTY interface for a motor temperature sensor.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.