steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | ATS22D32Q |
| Manufacturer | Schneider |
| Category | Soft Starts |
| Family | Altistart 22 |
| Rated Supply Voltage | 230...440 V (-15...10%) |
| Motor Power | 15 kW at 400 V, 15 kW at 440 V, 7.5 kW at 230 V |
| Factory Setting Current | 28.5 A |
| Power Dissipation | 44 W for standard applications |
| Utilisation Category | AC-53A |
| Type of Start | Start with torque control (current limited to 3.5 In) |
| IP Degree of Protection | IP20 |
| Assembly Style | With heat sink |
| Function Available | Internal bypass |
| Supply Frequency | 50...60 Hz (-10...10%) |
| Network Frequency | 45...66 Hz |
| Control Circuit Voltage | 220...230 V (-15...10%) at 50/60 Hz |
| Control Circuit Consumption | 20 W |
| Discrete Output Number | 2 |
| Discrete Output Type | Relay outputs 230 V running, alarm, trip, stopped, not stopped, starting, ready, C/O |
| Minimum Switching Current | Relay outputs 100 mA at 12 V, DC |
| Maximum Switching Current | Relay outputs 5 A at 250 V, AC resistive load, cos phi = 1; Relay outputs 5 A at 30 V, DC resistive load, cos phi = 1; Relay outputs 2 A at 250 V, AC inductive load, cos phi = 0.4, L/R = 20 ms; Relay outputs 2 A at 30 V, DC inductive load, L/R = 7 ms |
| Discrete Input Number | 3 |
| Discrete Input Type | (LI1, LI2, LI3) logic 5 mA 4.3 kOhm |
| Discrete Input Voltage | 24 V (<= 30 V) |
| Discrete Input Logic | (LI1, LI2, LI3) positive logic state 0 < 5 V and < 2 mA state 1 > 11 V and > 5 mA |
| Output Current | 0.4...1 Icl adjustable |
| PTC Probe Input | 750 Ohm |
| Communication Port Protocol | Modbus |
| Connector Type | 1 RJ45 |
| Communication Data Link | Serial |
| Physical Interface | RS485 multidrop |
| Transmission Rate | 4800, 9600 or 19200 bps |
| Installed Device | 31 |
| Protection Type | Phase failure: line, Thermal protection: motor, Thermal protection: starter |
| Marking | CE |
| Type of Cooling | Forced convection |
| Operating Position | Vertical +/- 10 degree |
| Dimensions (H x W x D) | 265 mm x 130 mm x 169 mm |
| Net Weight | 7 kg |
| Motor Power Range AC-3 | 7…11 kW at 200…240 V 3 phases, 15…25 kW at 380…440 V 3 phases |
| Motor Starter Type | Soft starter |
| Electromagnetic Compatibility | Conducted and radiated emissions level A conforming to IEC 60947-4-2, Damped oscillating waves level 3 conforming to IEC 61000-4-12, Electrostatic discharge level 3 conforming to IEC 61000-4-2, Immunity to electrical transients level 4 conforming to IEC 61000-4-4, Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3, Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
| Standards | EN/IEC 60947-4-2 |
| Product Certifications | GOST, C-Tick, UL, CCC, CSA |
| Vibration Resistance | 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6, 1.5 mm (f= 2…13 Hz) conforming to EN/IEC 60068-2-6 |
| Shock Resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
| Noise Level | 45 dB |
| Pollution Degree | Level 2 conforming to IEC 60664-1 |
| Relative Humidity | 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
| Ambient Air Temperature for Operation | -10…40 °C (without derating), 40…60 °C (with current derating 2.2 % per °C) |
| Ambient Air Temperature for Storage | -25…70 °C |
| Operating Altitude | <= 1000 m without derating, > 1000...< 2000 m with current derating of 2.2 % per additional 100 m |
| Sustainable Offer Status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| Mercury Free | Yes |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | End of Life Information |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
| California Proposition 65 | WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov |
The primary function of this soft starter is to control the acceleration and deceleration of three-phase asynchronous motors, reducing mechanical stress and extending the lifespan of the motor.
This soft starter operates with a control voltage of 230V and is suitable for motor supply voltages ranging from 230V to 440V.
The soft starter can handle motor power up to 15 kW at 400V or 440V, and up to 7.5 kW at 230V.
This soft starter is designed for use with three-phase asynchronous motors, commonly used in pumps and fans.
The dimensions of the soft starter are 130 mm in width, 169 mm in depth, and 265 mm in height.
The factory setting current for this soft starter is 28.5 A.
Yes, the soft starter includes a Modbus communication port with an RS485 interface, supporting transmission rates of 4800, 9600, or 19200 bps.
The soft starter can operate in ambient temperatures ranging from -10°C to 40°C without derating, and up to 60°C with current derating. It is also designed to withstand relative humidity levels from 0% to 95% without condensation.
The soft starter offers protection against phase failure, thermal protection for both the motor and the starter, and is compliant with various electromagnetic compatibility standards.
The soft starter uses forced convection for cooling, ensuring efficient heat dissipation during operation.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.