steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LP4K0910BW3 |
| Manufacturer | Telemecanique |
| Product Type | Contactor |
| Utilisation Category | AC-3, AC-4, AC-1 |
| Poles Description | 3 Poles |
| Pole Contact Composition | 3 Normally Open (NO) |
| Rated Operational Current | 20 A at <= 440 V AC AC-1 for power circuit, 9 A at <= 440 V AC AC-3 for power circuit |
| Auxiliary Contact Composition | 1 Normally Open (NO) |
| Coil Technology | Built-in bidirectional peak limiting diode suppressor |
| Control Circuit Voltage Limits | Operational: 0.7...1.30 Uc at <50°C, Drop-out: 0.1...0.7 Uc at <50°C |
| Rated Insulation Voltage | 600 V conforming to UL 508, 690 V conforming to IEC 60947-4-1 |
| Rated Impulse Withstand Voltage | 8 kV |
| Overvoltage Category | III |
| Mounting Support | Plate, Rail |
| Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101 and NF F 16-102 |
| Tightening Torque | 1.3 N.m - with screwdriver Philips No 2, flat Ø 6 mm, or pozidriv No 2 |
| Rated Operational Voltage | Power circuit: 690 V AC 50/60 Hz, Signalling circuit: <= 690 V AC 50/60 Hz |
| Conventional Free Air Thermal Current | 20 A (at 50°C) for power circuit, 10 A (at 50°C) for signalling circuit |
| Rated Making Capacity | 110 A AC for power circuit conforming to IEC 60947 |
| Rated Breaking Capacity | 110 A at 440 V conforming to IEC 60947 |
| Associated Fuse Rating | 25 A gG at <= 440 V for power circuit |
| Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| Operating Time | 10...20 ms coil de-energisation and NO opening, 30...40 ms coil energisation and NO closing |
| Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 |
| Mechanical Durability | 30 Mcycles |
| Maximum Operating Rate | 3600 cyc/h |
| Minimum Switching Current | 5 mA for signalling circuit |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Insulation Resistance | > 10 MOhm for signalling circuit |
| Dimensions (Height x Width x Depth) | 58 mm x 45 mm x 57 mm |
| Net Weight | 0.235 kg |
| Ambient Air Temperature for Operation | -25…50 °C |
| Ambient Air Temperature for Storage | -50…80 °C |
| Operating Altitude | 2000 m without derating |
| Product Certifications | UL, CSA |
| IP Degree of Protection | IP2x conforming to VDE 0106 |
| Protective Treatment | TC conforming to DIN 50016 and IEC 60068 |
| Flame Retardance | Requirement 2 conforming to NF F 16-101 and NF F 16-102, V1 conforming to UL 94 |
| Environmental Compliance | Green Premium product, REACh, RoHS, and China RoHS compliant |
The Telemecanique contactor is suitable for motor control applications and resistive loads. It is designed to handle AC-3 and AC-4 utilisation categories, making it versatile for various industrial switching applications.
Yes, this contactor is rated for operational voltages up to 690 V AC for power circuits and signalling circuits, making it compatible with a range of voltage systems.
The contactor has a rated operational current of 20 A for AC-1 power circuits at temperatures up to 50°C and 9 A for AC-3 power circuits.
The contactor measures 58 mm in height, 45 mm in width, and 57 mm in depth, which should be considered when planning for installation.
The coil voltage for the LP4K0910BW3 contactor is 24 V DC, which includes a built-in bidirectional peak limiting diode suppressor.
The conventional free air thermal current rating (Ith) for the power circuit is 20 A at 50°C.
The contactor supports screw clamp terminal connections, accommodating various cable sizes and types for both power and signalling circuits.
The mechanical durability of the contactor is rated at 30 million cycles, indicating a long operational lifespan under normal conditions.
The contactor is certified by UL and CSA, ensuring compliance with North American standards for safety and performance.
At the end of its life, the contactor should be disposed of according to European Union waste collection regulations to ensure environmentally responsible recycling and disposal.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.