steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | XPSDMB1132P |
| Alternative Part Number | XPSDMB1132P |
| Manufacturer | Schneider |
| Category | Safety Automation |
| Family | XPS |
| Supply Voltage | 24 V DC (- 20...20 %) |
| Output Type | Relay, 2 NO circuit(s), volt-free |
| Additional Circuits | 2 solid state outputs |
| Synchronisation Time Between Inputs | < 0.5 s |
| Power Consumption | <= 2.5 W |
| Input Protection Type | Internal, electronic |
| Control Circuit Voltage | 28 V DC |
| Maximum Line Resistance | 100 Ohm |
| Breaking Capacity | 180 VA holding AC-15 C300 relay output, 1800 VA inrush AC-15 C300 relay output |
| Output Thermal Current | 6 A per relay for relay output |
| Conventional Free Air Thermal Current | 12 A |
| Associated Fuse Rating | 4 A gG for relay output, 6 A fast blow for relay output |
| Minimum Output Current | 10 mA for relay output |
| Minimum Output Voltage | 17 V for relay output |
| Maximum Response Time on Input Open | 20 ms |
| Rated Insulation Voltage | 300 V (pollution degree 2) |
| Rated Impulse Withstand Voltage | 4 kV overvoltage category III |
| Local Signalling | 3 LEDs |
| Connections - Terminals | Captive screw clamp terminals, removable terminal block for various cable types and sizes |
| Mounting Support | 35 mm symmetrical DIN rail |
| Product Weight | 0.25 kg |
| Standards | EN/IEC 60204-1, EN 1088/ISO 14119, EN/IEC 60947-5-1 |
| Product Certifications | UL, CSA, TÜV |
| IP Degree of Protection | IP20 (terminals), IP40 (enclosure) |
| Ambient Air Temperature for Operation | -10…55 °C |
| Ambient Air Temperature for Storage | -25…85 °C |
| Sustainable Offer Status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| Mercury Free | Yes |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile, Circularity Profile, End Of Life Information, WEEE |
| PVC Free | Yes |
The safety module is designed for monitoring two coded magnetic switches, ensuring safe operation in machinery by verifying the switches are in the correct state before allowing machine operation.
This module can reach Performance Level e/category 4 conforming to EN/ISO 13849-1 and SILCL 3 conforming to EN/IEC 62061, making it suitable for high-risk safety applications.
The rated supply voltage for the module is 24 V DC with an acceptable range of -20% to +20%.
The module features two normally open (NO) relay outputs that are volt-free, along with two additional solid state outputs.
The module has internal, electronic protection for its inputs to ensure stability and reliability during operation.
The maximum power consumption of the module is 2.5 W.
The module can operate in ambient air temperatures ranging from -10 to 55°C and can be stored in temperatures ranging from -25 to 85°C.
The module is designed to be mounted on a 35 mm symmetrical DIN rail, which is a standard mounting support for industrial control equipment.
The module has compact dimensions, but for specific measurements, please refer to the product datasheet or contact us directly for detailed information.
The module is certified by UL, CSA, and TÜV, indicating compliance with international safety standards.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.