steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | SDW-532-2SM-LC15 |
| Alternative Part Number | SDW5322SMLC15 |
| Manufacturer | Westermo |
| Category | General Automation |
| Description | This part is a 3 x 10/100BaseTX, 2 x 100BaseFX |
| Country of Origin | Not specified |
| Maintenance | No maintenance is required as long as the unit is used as intended within the specified conditions |
| Installation | The unit should be mounted on a 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate |
| Mounting | This unit uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules: Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit |
| Declaration of Conformity | The manufacturer Westermo Teleindustri AB declares that the product is in conformity with the EC directive(s) 89/336/EEG Electromagnetic Compatibility (EMC) |
| Power Interface | Rated voltage is 12–48 VDC, polarity protected. Operating voltage is 9.6 – 57.6 VDC |
| Ethernet TX Interface | Electrical specification is IEEE std 802.3. 2000 edition. Data rate is 10 Mbit/s or 100 Mbit/s, manual or |
This part is an Industrial Ethernet 5-port switch. It is designed to provide very high dependability in harsh environmental conditions. It offers a flexible mix of TX (copper) and FX (fibre) interface.
The key features of this part include flexible mix of TX (copper) and FX (fibre) interface, TX shields individually isolated, wide DC power range, wide temperature range, redundant power, automatic MDI/MDI-X crossover, LED indicators for Power, Speed, Duplex, Link and Traffic, port monitoring, 35 mm DIN rail mounting, SC, ST and LC fibre interface, and Multi (MM) and single mode (SM) fibre.
This part can be used in a variety of applications. Some examples include as a 5-port switch, a fibre to copper converter, or an Ethernet isolator for STP network.
The power interface of this part has a rated voltage of 12–48 VDC, polarity protected. The operating voltage is 9.6 – 57.6 VDC. The connection is a detachable screw terminal and the connector size is 0.2 – 2.5 mm2 (AWG 24-12).
The Ethernet TX Interface of this part follows the IEEE std 802.3. 2000 edition. The data rate is 10 Mbit/s or 100 Mbit/s, manual or auto. The connection is an RJ-45, shielded. The circuit type is TNV-1 and the transmission range is 100 m.
The Ethernet FX Interface of this part follows the IEEE std 802.3. 2000 edition, multi or single mode, 1300 nm. The data rate is 100 Mbit/s. The connection is SC, ST, or LC. The transmission range is 2, 15 or 40 km.
The mechanical specifications for this part include a dimension of 35 x 121 x 119 mm, a weight of 0.2 kg, DIN-rail mounting, and a degree of protection of IP21.
No, this part does not require any maintenance as long as the unit is used as intended within the specified conditions.
This unit should be mounted on a 35 mm DIN-rail which is horizontally mounted on a wall or cabinet backplate. It uses convection cooling. To avoid obstructing the airflow around the unit, use the following spacing rules: Recommended spacing 25 mm (1.0 inch) above/below and 10 mm (0.4 inches) left/right the unit.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.