steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Telemecanique |
| Part Number | LC7K09015M7 |
| Product Type | TeSys K contactor |
| Device Short Name | LC7K |
| Application | Control of resistive loads and motor control circuits |
| Pole Configuration | 3 pole |
| Main Contact Arrangement | 3 normally open power contacts |
| Auxiliary Contact Arrangement | 1 normally closed auxiliary contact |
| Utilisation Categories | AC-1, AC-3, AC-3e and AC-4 |
| Rated Operational Voltage | Up to 690 V AC for power and signalling circuits |
| Rated Operational Current | 20 A AC-1 and 9 A AC-3/AC-3e at up to 440 V AC |
| Control Circuit Type | Silent AC coil, 50/60 Hz |
| Control Circuit Voltage | 220...230 V AC, 50/60 Hz |
| Motor Power Rating | 2.2 kW at 220...230 V AC and 4 kW at 380...690 V AC for AC-3 duty |
| Rated Impulse Withstand Voltage | 8 kV |
| Overvoltage Category | Category III |
| Conventional Free Air Thermal Current | 20 A for power circuit and 10 A for signalling circuit |
| Rated Making Capacity | 110 A AC for power and signalling circuits |
| Rated Breaking Capacity | 110 A at 220...440 V AC, 80 A at 500 V AC and 70 A at 660...690 V AC |
| Associated Fuse Rating | 25 A gG up to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit |
| Rated Insulation Voltage | 690 V to IEC standards and 600 V to UL/CSA ratings |
| Insulation Resistance | Greater than 10 MOhm for signalling circuit |
| Coil Inrush Power | 3 VA at 20 °C |
| Coil Hold-In Consumption | 3 VA at 20 °C |
| Heat Dissipation | 3 W |
| Operating Voltage Limits | 0.85...1.1 Uc for operation at below 50 °C |
| Drop-Out Voltage | At least 0.10 Uc at below 50 °C |
| Terminal Connection | Solder pins for printed circuit board installation |
| Maximum Operating Rate | 3600 cycles per hour |
| Minimum Switching Current | 5 mA for signalling circuit |
| Minimum Switching Voltage | 17 V for signalling circuit |
| Operating Time | 30...40 ms for coil energisation and contact closing; 30 ms for coil de-energisation and opening |
| Mechanical Durability | 10 million cycles |
| Electrical Durability | 1.3 million cycles at 9 A AC-3/AC-3e up to 440 V |
| Short-Time Withstand Current | 90 A for 1 s, 85 A for 5 s and 80 A for 10 s on the power circuit at 50 °C |
| Protection Rating | IP2X in accordance with VDE 0106 |
| Standards | EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, GB/T 14048.4 and JIS C8201-4-1 |
| Certifications | CB Scheme, CCC, UL, CSA, EAC, CE and UKCA |
| Ambient Storage Temperature | -50...80 °C |
| Operating Altitude | Up to 2000 m without derating |
| Flame Retardance | V1 to UL 94 |
| Dimensions | 58 mm high x 45 mm wide x 57 mm deep |
| Net Weight | 0.225 kg |
| Package Dimensions | 4.8 cm high x 6.2 cm wide x 6.6 cm long |
| Package Weight | 242 g |
This is a TeSys K contactor designed for control applications, including motor control and resistive load switching. It has 3 main poles with 3 normally open power contacts.
For AC-3 and AC-3e motor control duties, LC7K09015M7 is rated at 9 A at up to 440 V AC when operating below 60 °C.
For AC-1 resistive load applications, the contactor is rated at 20 A at up to 690 V AC when operating below 60 °C.
The contactor uses a 220 to 230 V AC control coil, suitable for 50/60 Hz control circuits.
It includes one instantaneous normally closed auxiliary contact, identified as 1 NC.
Typical AC-3 motor ratings are 2.2 kW at 220 to 230 V AC and 4 kW at 380 to 415 V AC, 440 V AC, or 690 V AC.
This TeSys K contactor is intended for printed circuit board mounting, using solder pin connections.
The power circuit has three normally open main contacts, making it suitable for switching three-phase loads.
The power circuit is rated for operational voltages up to 690 V AC at frequencies up to 400 Hz.
The rated insulation voltage is 690 V for the power circuit under IEC 60947-4-1, with 600 V ratings under UL 508 and CSA C22.2 No. 14.
The contactor has a rated impulse withstand voltage of 8 kV and is classified in overvoltage category III.
For the power circuit, the associated fuse ratings are 25 A gG at up to 440 V and 25 A aM. For the signalling circuit, the associated fuse rating is 10 A gG.
The contactor measures approximately 58 mm high, 45 mm wide and 57 mm deep, with a net weight of around 0.225 kg.
The mechanical durability is rated at 10 million cycles, making it suitable for frequent switching duties within its stated ratings.
Electrical durability is rated at 1.3 million cycles for 9 A AC-3 or AC-3e duty at up to 440 V, and 0.16 million cycles for 20 A AC-1 duty at up to 690 V.
The maximum operating rate is 3,600 cycles per hour, subject to the contactor being used within its specified electrical and environmental limits.
The closing time is approximately 30 to 40 ms from coil energisation to normally open contact closure. Opening time is approximately 30 ms from coil de-energisation to normally open contact opening.
The contactor is listed with standards including EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1 and GB/T 14048.4. Product certifications include CB Scheme, CCC, UL, CSA, EAC, CE and UKCA.
The contactor has an IP2X degree of protection in accordance with VDE 0106.
The specified ambient air temperature range for storage is -50 °C to 80 °C.
The contactor can operate at altitudes up to 2,000 metres without derating.
The inrush power and hold-in power consumption are both specified as 3 VA at 20 °C, with heat dissipation of approximately 3 W.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.