steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Part Number | 5SJ4114-7HG42 |
| Alternative Part Number | 5SJ41147HG42 |
| Product Range | SENTRON 5SJ4 |
| Product Type | Miniature circuit breaker |
| Application | Circuit protection for industrial and mechanical engineering installations |
| Number of Poles | 1 pole |
| Rated Current | 0.3 A |
| Tripping Characteristic | Type C |
| Voltage Type | AC/DC |
| Rated AC Supply Voltage | 400 V |
| Maximum AC Operating Voltage | 277 V according to UL 489 and CSA C22.2 No. 5-02 |
| Maximum DC Operating Voltage | 60 V for a single channel; 125 V for a two-channel arrangement |
| Rated Frequency | 50 Hz |
| Rated Insulation Voltage | 440 V AC |
| Breaking Capacity | 10 kA according to EN 60898; 15 kA according to IEC 60947-2 |
| UL 1077 Breaking Capacity | 10 kA AC |
| Power Loss | 1.2 W per pole at rated current |
| Overvoltage Category | Category III |
| Pollution Degree | 3 |
| Mounting Method | Standard mounting rail |
| Mounting Position | Any position |
| Modular Width | 1 module |
| Dimensions | 121 mm high × 18 mm wide × 76 mm deep |
| Installation Depth | 70 mm |
| Net Weight | Approximately 181 g |
| Terminal Type | Combined terminals at the top and bottom |
| Conductor Capacity | Up to 25 mm² with suitable end preparation |
| Maximum Terminal Tightening Torque | 3.5 N·m |
| Protection Rating | IP20 with conductors connected; IP40 around the operating handle |
| Touch Protection | Included |
| Supplementary Device Compatibility | Suitable for installation with compatible supplementary devices |
| Sealing Provision | Sealable design |
| Material Properties | Halogen-free and silicone-free |
| Operating Temperature | -25°C to +55°C |
| Storage Temperature | -40°C to +75°C |
| Maximum Relative Humidity | 95% |
| Typical Mechanical Endurance | Up to 20,000 switching operations |
| Compliance | Designed in accordance with relevant IEC, EN, UL and CSA circuit-breaker requirements |
It is a SENTRON 5SJ4 miniature circuit breaker designed to protect electrical circuits against overloads and short circuits.
The breaker has a rated current of 0.3 A at 40°C, making it suitable for low-current control, instrumentation and industrial circuits.
It is a single-pole, or 1P, miniature circuit breaker.
The 5SJ4114-7HG42 uses a Type C tripping characteristic, which accommodates moderate inrush currents while providing overload and short-circuit protection.
Yes. The breaker is designed for AC and DC applications, subject to the specified operating-voltage limits for each circuit arrangement.
The maximum operating voltage is 277 V AC under UL 489 and CSA requirements. For DC operation, the maximum is 60 V in a single-channel arrangement or 125 V in a two-channel arrangement.
The rated breaking capacity is 10 kA according to EN 60898 and 15 kA according to IEC 60947-2. The applicable figure depends on the installation standard.
It mounts onto a standard rail and can be installed in any mounting position.
The breaker occupies one modular width unit. It is approximately 18 mm wide, 121 mm high and 70 to 76 mm deep, depending on the dimensional reference used.
The combined terminals accept finely stranded conductors with end preparation from 0.75 mm² up to 25 mm².
The specified maximum tightening torque for copper conductors rated at 60°C or 75°C is 3.5 N·m, equivalent to 31 lb-in.
With conductors connected, the breaker has an IP20 protection rating. The operating-handle area is rated IP40.
The specified operating-temperature range is -25°C to 55°C. Its rated current is derated at higher temperatures, reaching approximately 0.26 A at 55°C.
The rated AC insulation voltage is 440 V. The device is classified for overvoltage category III and pollution degree 3.
Power loss is approximately 1.2 W per pole at the rated current under warm operating conditions.
Yes. The design incorporates touch protection and combined terminals at both the top and bottom.
Yes. The 5SJ4114-7HG42 is designed to accept compatible supplementary devices for suitable panel configurations.
Yes. Its compact rail-mounted design, Type C response and AC/DC capability make it suitable for mechanical engineering, industrial control panels and low-current equipment circuits.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.