steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 8AC122.60-3 |
| Alternative Part Number | 8AC122603 |
| Manufacturer | B&R |
| Category | Interface Module |
| Family | ACOPOS |
| Commodity Code | 853890 |
| Description | A modular interface module designed for seamless integration with B&R ACOPOS servo systems. |
| Slots for Plug-in Modules | 4 |
| Certification | CE, cULus, KC, FSC |
| Mains Input Voltage | 3 x 400 VAC to 480 VAC ± 10% |
| Frequency | 50 / 60 Hz ±4% |
| Installed Load | Max. 98 kVA |
| Starting Current at 400 VAC | 26 A |
| Integrated Line Filter | Yes, in accordance with EN61800-3, Category C3 |
| DC Bus Capacitance | 6600 µF |
| 24 VDC Supply | Input voltage 24 VDC +25% / -20% |
| Continuous Current | 128 A eff |
| Peak Current | 300 A eff |
| Nominal Switching Frequency | 5 kHz |
| Possible Switching Frequencies | 5 / 10 / 20 kHz |
| Motor Connection | Quantity: 1, Continuous current: 128 A eff |
| Protective Measures | Overload protection, Short circuit and ground fault protection |
| Max. Output Frequency | 598 Hz |
| Motor Holding Brake Connection | Response threshold for open line monitoring: Approx. 210 mA |
| Braking Resistors | Peak power int. / ext.: 8.5 / 250 kW, Continuous power int. / ext.: 0.24 / 24 kW |
| Limit Switch and Reference Inputs | Quantity: 3 |
| Enable Inputs | Quantity: 1 |
| Dimensions | Width: 70.5 mm, Height: 375 mm, Depth: 235.5 mm |
| Weight | Approx. 4.0 kg to 4.4 kg depending on the model |
The INTERFACE MODULE serves as a key component in industrial automation systems, providing a reliable interface for connecting and integrating various devices and machinery components. It facilitates communication and data exchange between different parts of a control system.
Yes, the module is designed with flexibility in mind and can be mounted in different orientations, including hanging vertically or lying horizontally, to accommodate various installation requirements.
The module is equipped with several protective measures, including overload protection and short circuit and ground fault protection, to ensure safe and reliable operation in industrial environments.
The module operates optimally within a specific ambient temperature range. Exceeding this range may require a reduction in continuous current to maintain performance and longevity of the module.
The module supports a variety of inputs and outputs, including digital I/O points configurable as 24 VDC input or output, analogue inputs, and connections for motor holding brakes and braking resistors.
The module handles motor holding brake connections electronically, with a response threshold for open line monitoring and the capability to support a maximum output current for the connected motor holding brake.
Proper air circulation is crucial for the module's operation, so it's recommended to maintain at least 80 mm clearance above and below the module during installation.
The module comes with several certifications, including CE, cULus, and KC, ensuring compliance with international standards and regulations.
The module has a maximum output frequency, which is monitored to protect against dual use in accordance with specific regulations. It is designed to abort current movement and output an error if this limit is exceeded.
Yes, the module's continuous current may need to be reduced depending on the installation elevation, particularly when starting at 500 m above sea level, to ensure proper operation.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.