steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
1 month ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | Z728 |
| Alternative Part Number | Z728 |
| Manufacturer | Pepperl + Fuchs |
| Type | Zener Barrier |
| Polarity | DC version, positive polarity |
| Nominal Resistance | Varies by model (240 Ω to 300 Ω) |
| Series Resistance | Varies by model (max. 250 Ω to 341 Ω) |
| Fuse Rating | Varies by model (50 mA to 80 mA) |
| Hazardous Area Connection | Terminals 1, 2 |
| Safe Area Connection | Terminals 7, 8 |
| Working Voltage | Max. 26.9 V, 26.5 V at 10 µA |
| Degree of Protection | IEC 60529 |
| Ambient Temperature Range | -20 ... 60 °C (-4 ... 140 °F) |
| Storage Temperature Range | -25 ... 70 °C (-13 ... 158 °F) |
| Relative Humidity | Max. 75%, without moisture condensation |
| Protection Degree | IP20 |
| Connection | Screw terminals, max. core cross-section 2 x 2.5 mm² |
| Mass | Approx. 150 g |
| Dimensions | 12.5 x 115 x 110 mm (0.5 x 4.5 x 4.3 in) |
| Construction Type | Modular terminal housing |
| Mounting | On 35 mm DIN mounting rail acc. to EN 60715:2001 |
| EC-Type Examination Certificate | Varies by model (BAS 00 ATEX 7096, BAS 01 ATEX 7005, etc.) |
| Group, Category, Type of Protection | Varies by model (e.g., ¬ II (1)GD, I (M1) [Ex ia] IIC, etc.) |
| Voltage Uo | 28 V |
| Current Io | Varies by model (93 mA to 120 mA) |
| Power Po | Varies by model (650 mW to 830 mW) |
| Maximum Safe Voltage Um | 250 V |
| Series Resistance (min.) | Varies by model (min. 235 Ω to 301 Ω) |
| International Approvals | FM, UL, CSA, IECEx approvals |
| Directive Conformity | Directive 94/9/EC, EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010, etc. |
A Zener Barrier is designed to limit the energy that can be transferred from a safe area to a hazardous area, thereby preventing the ignition of flammable gases or dust in the hazardous area. It achieves this by using Zener diodes to clamp the voltage and a fuse to disconnect the circuit in the event of an overvoltage.
Yes, the Zener Barrier is suitable for use in potentially explosive atmospheres and is certified with ATEX and IECEx approvals, making it appropriate for Zones 0, 1, and 2 for gas and dust hazards.
The Zener Barrier has a nominal resistance of 240 to 300 ohms, a series resistance of up to 341 ohms, and a fuse rating of 50 to 80 mA. It is designed to work with a voltage of 26.5 V at 10 µA leakage current.
The Zener Barrier is designed for mounting on a 35 mm DIN rail according to EN 60715:2001, which allows for easy installation and maintenance in control panels and equipment racks.
The Zener Barrier can operate in ambient temperatures ranging from -20 to 60 °C (-4 to 140 °F) and should be stored in temperatures from -25 to 70 °C (-13 to 158 °F). It is designed to function at a relative humidity of up to 75%, without moisture condensation.
The Zener Barrier supports screw terminal connections with a maximum core cross-section of 2 x 2.5 mm², allowing for secure and reliable wiring to both the hazardous and safe area terminals.
The Zener Barrier provides a degree of protection of IP20, which means it is protected against solid objects larger than 12.5 mm but is not protected against water ingress.
Yes, the Zener Barrier comes with EC-Type Examination Certificates and complies with various directives and standards such as EN 60079-0:2012, EN 60079-11:2012, and EN 60079-15:2010, ensuring its suitability for use in hazardous areas.
The Zener Barrier has dimensions of approximately 12.5 x 115 x 110 mm (0.5 x 4.5 x 4.3 in) and weighs around 150 grams, making it compact and lightweight for its function.
Some versions of the Zener Barrier come with a replaceable fuse feature, which allows for easy maintenance and replacement in case of a fault without the need to replace the entire unit.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.