steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part number | ATS480C11Y |
| Product range | Altivar Soft Starter ATS480 |
| Product type | Soft starter |
| Device short name | ATS480 |
| Intended motor type | Asynchronous motors |
| Typical application | Designed for process and infrastructure motor starting applications |
| Supply phases | 3 phase |
| Utilisation category | AC-3A, AC-53A |
| Main power supply voltage | 208 to 690 V AC |
| Voltage tolerance | -15% / +10% |
| Supply frequency | 50 to 60 Hz |
| Frequency tolerance | -20% / +20% |
| Rated operational current | 110 A normal duty at 40 °C |
| Heavy-duty current | 88 A at 40 °C |
| Torque control | Yes |
| Degree of protection | IP20 |
| Device connection | In the motor supply line or to the motor delta terminals |
| Motor power at 230 V | 30 kW normal duty in line; 22 kW heavy duty in line; 55 kW normal duty to delta terminals; 45 kW heavy duty to delta terminals |
| Motor power at 400 V | 55 kW normal duty in line; 45 kW heavy duty in line; 90 kW normal duty to delta terminals; 75 kW heavy duty to delta terminals |
| Motor power at 440 V | 55 kW normal duty in line; 45 kW heavy duty in line |
| Motor power at 500 V | 75 kW normal duty in line; 55 kW heavy duty in line |
| Motor power at 525 V | 75 kW normal duty in line; 55 kW heavy duty in line |
| Motor power at 660 V | 90 kW normal duty in line; 75 kW heavy duty in line |
| Motor power at 690 V | 90 kW normal duty in line; 75 kW heavy duty in line |
| Horsepower rating | 30 hp at 208 V normal duty; 25 hp at 208 V heavy duty; 40 hp at 230 V normal duty; 30 hp at 230 V heavy duty; 75 hp at 460 V normal duty; 60 hp at 460 V heavy duty; 100 hp at 575 V normal duty; 75 hp at 575 V heavy duty |
| Control circuit voltage | 110 to 230 V AC, 50/60 Hz |
| Control circuit tolerance | -15% / +10% |
| Additional control voltage | 24 V DC |
| Apparent power | 0.09 kVA |
| Integrated motor overload protection | Yes |
| Motor thermal protection class | Class 10E |
| Protection functions | Phase failure, starter thermal protection, motor overload, motor underload, excessive starting time, locked rotor, motor phase loss, line supply phase loss, motor thermal protection |
| Current limiting | 150% to 700% of In, with 5 x Ie maximum |
| Power loss, static current independent | 25 W |
| Power loss, current dependent | 302 W |
| Digital inputs | 4 |
| Digital input assignment | STOP, RUN, DI3 and DI4 |
| Digital input characteristics | Logic inputs, 3500 Ohm; DI3 and DI4 are programmable |
| Relay outputs | 3 |
| Relay output configuration | R1A 1 NO, R1B 1 NO, RIC programmable NO/NC |
| Relay switching capacity | Up to 2 A at 250 V AC or 2 A at 30 V DC |
| Digital outputs | 2 programmable digital outputs, up to 30 V |
| Analogue inputs | 1 analogue input with PTC/Pt 100 temperature probe compatibility; PTC1/AI1, PTC2 and PTC3 connections |
| Analogue outputs | 1 analogue output |
| Analogue output type | 0 to 20 mA or 0 to 10 V |
| Communication protocol | Modbus serial |
| Physical interface | 2-wire RS-485 |
| Connector type | RJ45 |
| Transmission speed | 1200 to 256000 bit/s |
| Transmission format | RTU, 8-bit data, configurable odd, even or no parity |
| Modbus address range | 0 to 227 |
| Display | Integrated display available |
| Available functions | External bypass control, pre-heating, smoke extraction, multi-motor cascade, second motor set, user management, single direction operation |
| Mounting position | Vertical, ±10° |
| Height | 290 mm |
| Width | 190 mm |
| Depth | 247 mm |
| Net weight | 8.3 kg |
| Rated insulation voltage | 690 V |
| Rated impulse withstand voltage | 6 kV |
| Pollution degree | 3 |
| Electromagnetic compatibility | Conforms to IEC 60947-4-2 and IEC 61000 series requirements for emissions and immunity |
| Operating temperature | -15 to 40 °C without derating; 40 to 60 °C with current derating of 2% per °C |
| Storage temperature | -25 to 70 °C |
| Relative humidity | 0 to 95% without condensation or dripping water |
| Operating altitude | Up to 1000 m without derating; 1000 to 4000 m with current derating of 1% per 100 m |
| Environmental class | Class 3C3 and Class 3S2 according to IEC 60721-3-3 |
| Standards | IEC 60947-4-2, UL 60947-4-2, IEC 60664-1 |
| Certifications and markings | CE, cULus, CCC, UKCA, RCM, EAC, DNV, ABS, BV, CCS |
| Sustainability status | Green Premium product |
| Mercury content | Mercury free |
| Country of origin | Indonesia |
| GTIN | 3606481089076 |
This unit is designed to control the starting and stopping of three-phase asynchronous motors. By ramping voltage more gradually than a direct-on-line start, it can help reduce mechanical shock, limit inrush current and improve control during motor acceleration and deceleration.
It is intended for asynchronous motors used in process and infrastructure applications. It can be used in installations where controlled starting, stopping and motor protection are important parts of the application.
This model is suitable for a three-phase power supply from 208 to 690 V AC at 50/60 Hz. The control supply range is 110 to 230 V AC, making it suitable for a wide variety of industrial panels and motor control arrangements.
The unit has a rated operational current of 110 A for normal duty and 88 A for heavy duty at 40°C. Although some listings may summarise it differently, the Schneider ATS480C11Y datasheet identifies this model as a 110 A soft starter.
Motor ratings depend on voltage and connection method. In the motor supply line, it is rated up to 30 kW at 230 V, 55 kW at 400 V and 440 V, 75 kW at 500 V and 525 V, and up to 90 kW at 660 V and 690 V under normal duty. For heavy duty use, the ratings are lower, for example 45 kW at 400 V and 75 kW at 690 V.
Yes. This soft starter can be connected in the motor supply line or to the motor delta terminals, depending on the application and motor arrangement. This gives added flexibility when designing or replacing a motor starting system.
Yes. It includes integrated motor overload protection and Class 10E thermal protection. Available protection functions include phase failure, current overload, underload, excessive starting time, locked rotor detection, motor phase loss and line supply phase loss.
The unit includes Modbus serial communication via RJ45 with a 2-wire RS-485 physical interface. It also supports optional communication modules for networks such as PROFINET, Profibus DP V1, Modbus TCP/EtherNet/IP and CANopen.
It includes 4 digital inputs, 3 relay outputs, 2 programmable digital outputs, 1 analogue output and analogue input capability for PTC/Pt100 temperature probes. This helps the unit integrate into broader control systems and motor monitoring arrangements.
Yes. The unit is equipped with a display screen, which can make commissioning and local parameter viewing more convenient within the panel environment.
This model is rated IP20. That means it is intended for installation inside a suitable electrical enclosure where additional protection from dust, moisture and accidental contact can be provided by the panel design.
The unit measures 290 mm high, 190 mm wide and 247 mm deep, with a net weight of 8.3 kg. These dimensions can be useful when checking panel space for a replacement or new installation.
It can operate from -15°C to 40°C without derating. From 40°C to 60°C, current derating applies at 2% per °C. For storage, the specified temperature range is -25°C to 70°C.
Yes. Torque control is included, which can be beneficial in applications where smoother and more controlled motor starting behaviour is required.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.