steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | LAD8N20 |
| Alternative Part Number | LAD8N20 |
| Manufacturer | Schneider |
| Category | Safety Automation |
| Product Type | Auxiliary Contact Block |
| Mounting Location | Side |
| Pole Contact Composition | 2 Normally Open (NO) |
| Rated Operational Voltage (Ue) | 690 V AC 25...400 Hz |
| Rated Insulation Voltage (Ui) | 690 V IEC 60947-5-1, 600 V UL, 600 V CSA |
| Conventional Free Air Thermal Current (Ith) | 10 A at 60 °C (140 °F) |
| Rated Operational Current (Ie) | 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13, 0.1 A at 600 V DC-13 |
| Irms Rated Making Capacity | 140 A AC IEC 60947-5-1, 250 A DC IEC 60947-5-1 |
| Permissible Short-Time Rating | 100 A for 1 s, 120 A for 500 ms, 140 A for 100 ms |
| Protection Type | GG fuse 10 A |
| Mechanical Durability | 30 Million cycles |
| Minimum Switching Current | 5 mA |
| Minimum Switching Voltage | 17 V |
| Non-Overlap Time | 1.5 ms on de-energisation and energisation, no overlap between NC and NO contact |
| Insulation Resistance | > 10 MOhm |
| Connections - Terminals | Screw clamp terminals for cables 1…4 mm², flexible with or without cable end, and solid |
| Tightening Torque | 1.7 N.m with screwdriver flat Ø 6 mm or Philips No 2 |
| Height | 76 mm |
| Width | 12.5 mm |
| Depth | 76 mm |
| IP Degree of Protection | IP20 conforming to IEC 60529 |
| Protective Treatment | TH conforming to IEC 60068 |
| Ambient Air Temperature for Operation | -5…60 °C (23…140 °F) |
| Ambient Air Temperature for Storage | -60…80 °C (-76…176 °F) |
| Operating Altitude | Up to 3000 m without derating in temperature |
| Product Certifications | IECEE CB Scheme, UL, CSA, CCC, EAC |
| Standards | EN/IEC 60947-5-1, UL 60947-5-1, CSA C22.2 No 60947-5-1, GB/T 14048.5 |
| Sustainable Offer Status | Green Premium product |
| REACh Regulation | REACh free of SVHC |
| EU RoHS Directive | Compliant |
| Toxic Heavy Metal Free | Yes |
| Mercury Free | Yes |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile |
| WEEE | Must be disposed of following specific waste collection in the European Union |
An auxiliary contact block is used in conjunction with contactors to provide additional switching operations, such as signalling and interlocking functions, without bearing the main power load of the circuit.
No, the LAD8N20 is designed to be side-mounted on specific TeSys series contactors, ranging from LC1D09 to LC1D150 models.
The LAD8N20 features screw clamp terminals, which provide a secure and reliable connection for the wires.
The rated operational voltage for this contact block is 690 V AC at frequencies between 25 and 400 Hz.
The conventional free air thermal current rating (Ith) for this part is 10 A at 60°C.
The LAD8N20 can operate in ambient air temperatures ranging from -5°C to 60°C and at altitudes up to 3000 metres without derating.
This auxiliary contact block has an IP20 degree of protection, ensuring safety from solid objects larger than 12mm but not from liquids.
The LAD8N20 has 2 poles, both of which are normally open (NO) contacts.
The mechanical durability of the LAD8N20 is rated at 30 million cycles, indicating its ability to withstand repeated operations.
This auxiliary contact block is certified by international standards including EN/IEC 60947-5-1, UL 60947-5-1, and CSA C22.2 No 60947-5-1.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.