steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 3RX9501-2BA00 |
| Manufacturer | Siemens |
| Type of Device | AS-Interface Power Supply Unit IP20 |
| Version | Single Output |
| Input Voltage Nominal Value AC | 120V / 230V |
| Input Voltage Range AC | 85 to 132V AC / 176 to 253V AC |
| Mains Buffering Time | > 20 ms at Ia rated |
| Line Frequency | 50/60 Hz |
| Mains Frequency Range | 47 to 63 Hz |
| Output Voltage Rated Value DC | 30 V |
| Output Current Rated | 2.6 A (max. 100 W) |
| Residual Ripple | < 300 mVpp (0 to 10 kHz), < 50 mVpp (10 to 500 kHz) |
| Efficiency | 84% at Ua rated, Ia rated |
| Protective and Monitoring Functions | Output overvoltage protection, current limitation, short-circuit protection |
| Safety Class | I according to EN 60 950/IEC 950 |
| Electrical Isolation | SELV according to EN 60 950 and EN 50 178 |
| Protection Class IP | IP20 |
| EMC | Interference immunity EN 61 000-6-2, emitted interference class B according to EN 55 022 |
| Ambient Temperature Operation | -10°C to +70°C |
| Ambient Temperature Storage | -25°C to +80°C |
| Humidity Rating | Climatic class DIN 50010, relative humidity max. 100% without condensation |
| Mounting Type | Fixing on standard mounting rail DIN EN 59 022-35 x 7.5 mm snap-on |
| Dimensions (W x H x D) | 50 mm x 125 mm x 125 mm |
| Weight | Approx. 0.5 kg |
The Siemens 3RX9501-2BA00 is an AS-Interface power supply unit designed to provide a stable and regulated 30 V DC power supply with integrated ground fault detection and AS-i data decoupling.
Yes, the power supply unit can accommodate two input voltage ranges: 85 to 132 V AC and 176 to 253 V AC, making it versatile for various network configurations.
The unit's output features include a rated voltage of 30 V DC, a rated current of 2.6 A, low residual ripple, and short-circuit protection. It is designed to be floating according to AS-Interface specifications and has an output overvoltage protection.
The power supply unit has integrated ground fault detection that identifies any ground faults in the AS-i + or AS-i - lines and only switches off the affected 'AS-i + SWITCHED' output to protect the system.
The Siemens 3RX9501-2BA00 has an efficiency rating of approximately 84% at rated power, which contributes to its energy-efficient operation.
The power supply unit is designed to operate within an ambient temperature range of -10 °C to +70 °C, ensuring reliable performance in various working environments.
The Siemens 3RX9501-2BA00 is suitable for snap-on mounting onto a standard mounting rail DIN EN 50022-35 x 7.5 mm, which allows for easy installation and secure placement.
The power supply unit comes with general product approvals and complies with EMC standards, ensuring it meets the necessary regulatory requirements for electronic devices.
The IP20 rating of the Siemens 3RX9501-2BA00 indicates that the unit is protected against solid objects larger than 12.5 mm but is not protected against water, making it suitable for use in dry and controlled environments.
The power supply unit features LED indicators for operational status, overload, and ground fault detection, allowing for easy monitoring of the output voltage and current conditions.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.