steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Part Number | 3KD3840-0PE20-0 |
| Alternative Part Number | 3KD38400PE200 |
| Product Range | SENTRON |
| Product Type | 3KD switch disconnector |
| Device Design | Switch |
| Rated Operational Current | 250 A |
| Number of Poles | 4-pole |
| Switch Disconnector Size | Size 3 |
| Mounting Type | Fixed mounting |
| Operating Mechanism | Front operating mechanism, centre-mounted |
| Switch Position Indicator | Door-coupling rotary operating mechanism with ON-OFF indication |
| Actuating Element | Supplied without handle |
| Terminal Type | Flat terminal connection for main current circuit |
| Rated Insulation Voltage | 1,000 V |
| Rated Surge Voltage Resistance | 12 kV |
| Overvoltage Category | Category IV |
| Pollution Degree | 3 |
| Rated Operating Power | 160 kW at AC-23 A, 500 V |
| Mechanical Service Life | 15,000 operating cycles typical |
| Electrical Endurance | 1,000 operating cycles at AC-23 A, 690 V; 1,000 operating cycles at DC-23 A, 440 V |
| Short-Time Withstand Current | 13 kA for 1 second at 1,000 V AC / 440 V DC |
| Short-Circuit Making Capacity | Minimum 36 kA without fuse link |
| Conditional Short-Circuit Current | 65 kA at 415 V with moulded case circuit breaker; 100 kA at 500 V and 690 V with gG fuse |
| Power Loss | 6 W per pole; 24 W per device at conventional rated thermal current |
| Degree of Protection | IP00; IP20 with closed switch and cover or cable lug cover |
| Auxiliary Contact Provision | Prepared for auxiliary switch extension, with up to 6 NC and 6 NO contacts |
| Suitable Applications | Main switch, switch disconnector, emergency off switch, safety switch, and maintenance/isolating switch duties |
| Copper Conductor Connection | Stranded conductor with lug: 1 x 6–240 mm² or 2 x 6–150 mm² to DIN 46234; 1 x 16–185 mm² or 2 x 16–150 mm² to DIN 46235 |
| Aluminium Conductor Connection | Stranded conductor with lug: 1 x 25–240 mm² or 2 x 25–120 mm² |
| Copper Busbar Connection | 1 x 30 x 10 mm² |
| Height | 164 mm |
| Width | 234 mm |
| Depth | 93.5 mm |
| Net Weight | 3,540 g |
| Mounting Position | Any |
| Fastening Method | Screw fixing |
| Operating Temperature Range | -25 °C to 70 °C |
| Storage Temperature Range | -50 °C to 80 °C |
| Reference Code | Q according to IEC 81346-2 |
This is a SENTRON 3KD switch disconnector designed for fixed mounting. It is a 4-pole, Size 3 unit with a 250 A operational current rating and a front operating mechanism.
The device has an operational current rated value of 250 A, making it suitable for higher-current low-voltage isolation and switching applications.
This switch disconnector has 4 poles, allowing it to isolate four conductors in a compatible electrical installation.
No. The 3KD3840-0PE20-0 is supplied as a basic unit without a handle. It uses a front operating mechanism with a door-coupling rotary ON-OFF switch position indication arrangement.
The main current circuit uses flat terminals. It can accommodate suitable copper or aluminium conductors with lugs, depending on the conductor size and configuration.
The rated insulation voltage is 1,000 V, and the rated surge voltage withstand value is 12 kV.
The short-time withstand current, Icw, is rated at 13 kA for 1 second at 1,000 V AC or 440 V DC.
The base device is rated IP00. With a closed switch and suitable cover or cable lug cover, the rating can be IP20.
The device is rated for operation from -25 °C to 70 °C. For storage, the permitted temperature range is -50 °C to 80 °C.
The unit measures approximately 164 mm high, 234 mm wide, and 93.5 mm deep. Its net weight is approximately 3,540 g.
Yes. The datasheet lists this device as suitable for use as a main switch, switch disconnector, emergency off switch, safety switch, and maintenance switch.
The typical mechanical service life is 15,000 operating cycles, with electrical endurance ratings specified for AC-23 A and DC-23 A duty categories.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.