steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | DLP120-24-1/E |
| Alternative Part Number | DLP120241E |
| Manufacturer | Lambda |
| Output Voltage | 24V DC |
| Output Current | 5.0 A |
| Output Power | 120 W |
| Output Voltage Adjustment | 21.6 - 28 V |
| Load Regulation | 192 mV |
| Line Regulation | 120 mV |
| Ripple/Noise (0-60°C) | 240 mV |
| AC Input Voltage & Frequency | 85-132/170-265VAC, 47-63Hz Auto select or 120-370VDC |
| Input Current 100/230VAC | 2.4/1.3 A |
| Efficiency 100/230VAC | 83/85 % |
| Power Factor | Meets EN61000-3-2 (DLP180, 240: >0.95) |
| Inrush Current (Typ) 100/230VAC | 20/45 A |
| Leakage Current | Less than 0.75 mA |
| Hold-up Time 100/230VAC | 20/30 ms (Semi F47 Compliance, DLP 180 & 240 only) |
| Overcurrent Protection | >105%, Fold Back |
| Overvoltage Protection | 30-35V, latching, cycle AC line to reset |
| LED Indicators | Green LED = DC ok, Red LED = overcurrent |
| Operating Temperature | Convection cooled, -10°C to 60°C, derate linearly to 60% load from 50 to 60°C |
| Storage Temperature | -30°C to +85°C |
| Humidity (Non-Condensing) | 30-90% operating, 10-95% non operating |
| Withstand Voltage | Input - Ground 2kVAC, Input to Output 3kVAC, Output - Ground 500VAC |
| Vibration | 9.8m/s² (1.0G) at DIN rail; (10-55Hz: 9.8m/s² Constant, X,Y, Z each 1 hour) |
| Shock | 196m/s² (20G) |
| Safety Agency Approvals | UL508, UL60950-1, CSA60950-1, EN60950-1, CE, EN50178 Cat III (Pri) |
| Conducted EMI | FCC-B, EN55011/EN55022-B, VCCI-B; Meets IEC61000-4-1 |
| Radiated EMI | EN55011/EN55022-B, FCC-Class B, VCCI-B |
| ESD | IEC61000-4-2 ±10kV (Air), ±5kV (Contact) |
| Radiated RFI | IEC61000-4-3 80-1000MHz,12V/m 80% AM 1kHz |
| Fast Transient Burst | IEC61000-4-4 2.4kV 5kHz |
| Lightning Surge | IEC61000-4-5 4.4kV, 1.2x50μs (Common Mode) 2.4kV 1.2x50μs (Normal) |
| Conducted RFI | IEC61000-4-6 150kHz-80MHz, 12V, 80% AM 1kHz |
| Magnetic Field | IEC61000-4-8 36A/m |
| Voltage Dips | IEC61000-4-11 70% 10ms, 40% 100ms, 0% 5s |
| Size | 60 x 97 x 110 mm |
| Weight | 540 g |
The DLP120-24-1/E is a rail panel mount power supply designed for DIN rail mounting, providing a 24V dc output voltage.
Yes, the output voltage of the DLP120-24-1/E can be adjusted from 21.6V to 28V.
The power supply accepts an AC input voltage range of 85-132/170-265VAC, with auto-selection, and can also operate with a DC input of 120-370VDC.
Yes, the DLP120-24-1/E is convection cooled, which means it does not require a fan for cooling, relying on natural convection instead.
The efficiency rating of the DLP120-24-1/E is approximately 83% to 85% when operating at 100/230VAC.
The DLP120-24-1/E includes overcurrent protection, which operates above 105% load with a fold-back characteristic, and overvoltage protection with a latching feature that requires cycling the AC line to reset.
The power supply has a green LED to indicate DC ok status and a red LED to signal overcurrent conditions.
The operating temperature range for the DLP120-24-1/E is from -10°C to 60°C, with derating linearly to 60% load from 50°C to 60°C.
The power supply is UL508 listed and conforms to standards such as EN60950-1 and CE, among others.
The dimensions of the DLP120-24-1/E are 60 x 97 x 110 mm, and it weighs approximately 540 grams.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.