steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 5SU1654-7KK06 |
| Alternative Part Number | 5SU16547KK06 |
| Manufacturer | Siemens |
| Product Type | RCBO (Residual Current Circuit Breaker with Overcurrent Protection) |
| Brand Name | SENTRON |
| Design | Instantaneous |
| Number of Poles | 2 (1P+N) |
| Tripping Characteristic Class | C |
| Mechanical Service Life | Typically 10,000 switching cycles |
| Overvoltage Category | III |
| Degree of Pollution | 2 |
| Surge Current Resistance | 1 kA at (8/20) µs |
| Type of Voltage | AC |
| Rated Operating Current | 6 A |
| Supply Voltage (AC) | Rated value 230/240 V |
| Operating Frequency | 50 Hz |
| Protection Class IP | IP20 (with distribution board installed and conductors connected) |
| Breaking Capacity | 10 kA according to EN 61009-1 |
| Switching Capacity Current | 10 kA acc. to EN 60898, 35 kA acc. to IEC 60947-2 |
| Rated Residual Switching Capacity | 10 kA according to IEC 61009-1 |
| Energy Limiting Class | 3 |
| Power Loss | 1.9 W per pole at AC in hot operating state, maximum 3.8 W |
| Tripping Residual Current | Rated value 300 mA |
| Residual Current Type | A |
| Neutral Conductor Switching | Yes |
| Touch Protection | Yes |
| Halogen-Free | Yes |
| Silicon-Free | Yes |
| Connectable Conductor Cross-Section | Solid: 0.75 mm² min - 35 mm² max, Stranded: 0.75 mm² min - 35 mm² max, Finely stranded: 0.75 mm² min - 25 mm² max |
| Tightening Torque | 2.5 N·m min - 3 N·m max |
| Position of Power Supply Cord | Either top or bottom |
| Mechanical Design | Height: 90 mm, Width: 36 mm, Depth: 77 mm, Installation depth: 70 mm, Number of width units: 2 |
| Mounting Position | Any |
| Net Weight | 255 g |
| Environmental Conditions | Max. 95% humidity, Ambient temperature operational: -25 °C min to 55 °C max, Ambient temperature storage: -40 °C min to 75 °C max |
| Number of Test Cycles | 28 for environmental testing according to IEC 60068-2-30 |
| Reference Code | According to DIN EN 61346-2 F, According to IEC 81346-2 F |
This Siemens component is an RCBO, which stands for Residual Current Circuit Breaker with Overcurrent protection. It is designed to protect electrical circuits from both overcurrents, such as short circuits and overload, and residual currents that could lead to electric shock hazards.
The RCBO has a C-type tripping characteristic, meaning it is suitable for commercial and industrial applications with moderate inrush currents. It is designed to withstand sudden high current loads without tripping unnecessarily.
The rated residual current for this RCBO is 300 mA, which is the level of fault current at which the device will trip to protect the circuit.
The RCBO should be installed in a distribution board with an IP20 protection class when connected conductors are installed. It can be mounted in any position and requires a space of two modular width units in the distribution board.
The mechanical service life of the RCBO is typically 10,000 switching cycles, indicating its durability and reliability over time.
The RCBO can operate within an ambient temperature range of -25 °C to 55 °C and can be stored in temperatures ranging from -40 °C to 75 °C. It is designed to withstand up to 95% humidity without condensation.
Yes, the RCBO is both halogen-free and silicon-free, making it suitable for use in environments where these characteristics are required for safety or performance reasons.
The breaking capacity of the RCBO is 10 kA according to EN 61009-1, with a rated residual switching capacity of 10 kA according to IEC 61009-1.
Yes, this RCBO includes neutral conductor switching, which means it can disconnect both the live and neutral conductors in the event of a fault, providing additional safety.
The supply voltage for this RCBO at AC is rated at 230/240 V, and the operating current at AC is rated at 6 A.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.