steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | ATV71HD11N4Z |
| Product Range / Family | Altivar 71 (ATV71) |
| Product Type | Variable Speed Drive (Inverter Drive) |
| Part Description | Three-phase variable speed drive from Schneider Electric’s Altivar 71 range, designed to provide precise motor speed and torque control for demanding industrial machinery using a 380–480 V AC supply, with integrated EMC filtering and built-in Modbus and CANopen communications. |
| Supply Voltage (Rated) | 380…480 V AC (3-phase), tolerance -15%…+10% |
| Supply Voltage Limits | 323…528 V AC |
| Supply Frequency | 50/60 Hz (±5%) |
| Network Frequency Limits | 47.5…63 Hz |
| Motor Power Rating | 11 kW (15 hp) at 380…480 V (3-phase) |
| Line Current | 30 A (at 480 V, 11 kW) / 36.6 A (at 380 V, 11 kW) |
| Apparent Power | 24.1 kVA (at 380 V, 3-phase, 11 kW) |
| Prospective Line Short-Circuit Current (Isc) | ≤ 22 kA (3-phase) |
| Nominal Output Current | 21 A (at 4 kHz, 460 V) / 27.7 A (at 4 kHz, 380 V) |
| Maximum Transient Output Current | 41.6 A for 60 s / 45.7 A for 2 s |
| Output Frequency Range | 0.1…599 Hz |
| Switching Frequency | 1…16 kHz adjustable (4…16 kHz with derating factor) |
| Nominal Switching Frequency | 4 kHz |
| EMC Filter | Integrated |
| Supported Motor Types | Asynchronous motors; synchronous motors |
| Motor Cable Length (Max.) | Up to 50 m (shielded) / up to 100 m (unshielded) |
| Communication Protocols | Modbus; CANopen |
| Modbus Physical Interface | RS-485 (2-wire) |
| Modbus Connectors | RJ45 (front) and RJ45 (terminal) |
| CANopen Connector | Male SUB-D 9 on RJ45 |
| Address Range | Modbus: 1…247 / CANopen: 1…127 |
| Analogue Inputs | 2 inputs: AI1 (±10 V differential), AI2 (0…10 V or 0…20 mA, configurable) |
| Analogue Output | 1 output: 0…10 V or 0…20 mA (configurable) |
| Discrete Inputs | 7 digital inputs (24 V DC, configurable; LI6 can be set for PTC input) |
| Discrete Outputs | 2 relay outputs (one NO/NC relay and one NO relay, configurable) |
| Mounting Orientation | Vertical (±10°) |
| Dimensions (W × H × D) | 210 mm × 295 mm × 213 mm |
| Net Weight | 8 kg |
| IP Rating (as specified) | IP21; IP41 (upper part); IP54 (lower part); IP20 (upper part without blanking plate) |
| Pollution Degree | 2 (EN/IEC 61800-5-1) |
| Operating Temperature | -10…+50 °C (without derating) |
| Storage Temperature | -25…+70 °C |
| Operating Altitude | ≤ 1000 m without derating; 1000…3000 m with current derating (1% per 100 m) |
| Noise Level | 57.4 dB |
| Product Certifications (as listed) | UL, CSA, C-Tick, GOST, NOM 117 |
| Marking | CE |
It controls the speed and torque of compatible AC motors by varying the output frequency and voltage, enabling smoother starting, controlled acceleration/deceleration, and energy-efficient operation on industrial machines. This model supports an output frequency range of 0.1 to 599 Hz.
It is designed for a 3-phase supply in the 380 to 480 V range (permitted supply limits are 323 to 528 V), with a supply frequency of 50/60 Hz (network frequency limits 47.5 to 63 Hz).
It is rated for 11 kW (15 hp) motors on a 380 to 480 V, 3-phase supply, making it suitable for complex, higher-power machinery applications.
Nominal output current is 21 A at 4 kHz and 460 V (3-phase), or 27.7 A at 4 kHz and 380 V (3-phase). It also supports higher transient current for short durations (41.6 A for 60 s and 45.7 A for 2 s).
It is intended for both asynchronous and synchronous motors, with multiple control profiles including sensorless flux vector control and voltage/frequency modes. Closed-loop operation is possible when used with an encoder interface option.
It includes Modbus and CANopen communication. Modbus uses a 2-wire RS-485 physical interface with RTU framing, and CANopen supports multiple baud rates up to 1 Mbps.
It provides RJ45 connectivity for Modbus (one on the front face and one on the terminal area) and a CANopen connection via a male SUB-D 9 presented on an RJ45-style interface.
Built-in I/O includes 2 analogue inputs, 1 analogue output, 7 discrete inputs, and 2 relay-type discrete outputs. The analogue and discrete functions are configurable to suit typical speed reference and control schemes.
Analogue inputs include one differential voltage input (±10 V) and one input that can be set for either 0–20 mA or 0–10 V. The analogue output can be set for either 0–20 mA, 0–10 V, or a 10 V logic-style output (limited current).
The nominal switching frequency is 4 kHz. It is adjustable from 1 to 16 kHz, with derating required in certain higher-frequency operating conditions.
Maximum motor cable length is 50 metres with shielded cable, or 100 metres with unshielded cable (application conditions may require additional measures for best results).
It should be installed vertically (within ±10°), away from heat sources, and with adequate free space to allow airflow from bottom to top. In enclosures, ensure ventilation openings (and fans if required) provide airflow at least equal to the drive’s internal fans.
It is commonly specified with IP21 overall, with additional ratings depending on configuration (for example IP41 on the upper part and IP54 on the lower part). Removing the protective blanking cover from the top reduces the upper protection to IP20.
Typical operating ambient temperature is -10 to 50°C without derating, relative humidity 5–95% (without condensation), and altitude up to 1000 m without derating. From 1000 to 3000 m, current derates by 1% per 100 m.
Approximate dimensions are 295 mm (H) x 210 mm (W) x 213 mm (D), with a net weight of about 8 kg. Allow additional space for wiring access and cooling clearance.
Yes. This drive includes an integrated EMC filter, which can help simplify compliance planning in many industrial installations.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.