steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | ATS22C25S6U |
| Manufacturer | Schneider |
| Category | Soft Starts |
| Family | Altistart 22 |
| Phase | 3 Phase |
| Rated Supply Voltage | 208...600 V - 15...10 % |
| Maximum Horse Power | 75 hp at 208 V, 100 hp at 230 V, 200 hp at 460 V, 250 hp at 575 V |
| Control Circuit Voltage | 110 V - 15...10 % 50/60 Hz |
| Power Dissipation | 129 W for standard applications |
| Utilisation Category | AC-53A |
| Type of Start | Start with torque control (current limited to 3.5 In) |
| Starter Rating | 250 A connection in the motor supply line for standard applications |
| IP Degree of Protection | IP00 |
| Dimensions (H x W x D) | 425 mm x 206 mm x 299 mm |
| Product Weight | 33 kg |
| Cooling Type | Forced convection |
| Operating Position | Vertical +/- 10 degree |
| Electromagnetic Compatibility | Conducted and radiated emissions level A IEC 60947-4-2, Damped oscillating waves level 3 IEC 61000-4-12, Electrostatic discharge level 3 IEC 61000-4-2, Immunity to electrical transients level 4 IEC 61000-4-4, Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3, Voltage/current impulse level 3 IEC 61000-4-5 |
| Standards | EN/IEC 60947-4-2 |
| Product Certifications | C-Tick, CSA, GOST, UL, CCC |
| Vibration Resistance | 1 gn 13…200 Hz EN/IEC 60068-2-6, 1.5 mm 2…13 Hz EN/IEC 60068-2-6 |
| Shock Resistance | 15 gn 11 ms EN/IEC 60068-2-27 |
| Noise Level | 56 dB |
| Pollution Degree | Level 2 IEC 60664-1 |
| Relative Humidity | 0…95 % without condensation or dripping water EN/IEC 60068-2-3 |
| Ambient Air Temperature for Operation | 14…104 °F (-10…40 °C) without derating, 104…140 °F (40…60 °C) with current derating 2.2 % per °C |
| Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
| Operating Altitude | <= 3280.84 ft (1000 m) without derating, > 3280.84...< 6561.68 ft (> 1000...< 2000 m) with current derating of 2.2 % per additional 100 m |
| Sustainable Offer Status | Green Premium product |
| Mercury Free | Yes |
| Communication Port Protocol | Modbus |
| Connector Type | 1 RJ45 |
| Discrete Output Number | 2 |
| Discrete Output Type | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O; Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O |
| Minimum Switching Current | 100 mA at 12 V DC (relay outputs) |
| Maximum Switching Current | 5 A 250 V AC resistive 1 relay outputs, 5 A 30 V DC resistive 1 relay outputs, 2 A 250 V AC inductive 0.4 20 ms relay outputs, 2 A 30 V DC inductive 7 ms relay outputs |
| Discrete Input Number | 3 |
| Discrete Input Type | (LI1, LI2, LI3) logic, 5 mA 20 kOhm |
| Discrete Input Voltage | 110 V <= 121 V |
| Discrete Input Logic | Positive logic LI1, LI2, LI3 at State 0: < 20 V and <= 15 mA at State 1: > 79 V, <= 2 mA |
| Output Current | 0.4...1 Icl adjustable |
| PTC Probe Input | 750 Ohm |
| Communication Data Link | Serial |
| Transmission Rate | 4800, 9600 or 19200 bps |
| Installed Device | 31 |
| Protection Type | Phase failure line, Thermal protection motor, Thermal protection starter |
| Supply Voltage Limits | 177…660 V |
| Supply Frequency | 50...60 Hz - 10...10 % |
| Network Frequency | 45...66 Hz |
| Device Connection | In the motor supply line |
| Assembly Style | With heat sink |
| Function Available | Internal bypass |
| Sustainable Offer Status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Pro-active compliance (Product out of EU RoHS legal scope) |
| China RoHS Regulation | China RoHS Declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | End Of Life Information |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
The primary function of this soft starter is to control the starting and stopping of asynchronous motors, reducing mechanical stress and electrical peak currents.
This soft starter is suitable for applications involving pumps and fans, where smooth motor control is essential.
The rated supply voltage range for this soft starter is 208 to 600 V, with a tolerance of -15% to +10%.
This soft starter can handle a maximum motor power of 250 hp at 575 V.
The dimensions of this soft starter are 206 mm in width, 299 mm in depth, and 425 mm in height.
This soft starter uses forced convection for cooling.
The operating temperature range for this soft starter is -10°C to 40°C without derating, and up to 60°C with current derating.
Yes, this soft starter includes thermal protection for both the motor and the starter itself.
This soft starter supports the Modbus communication protocol.
The weight of this soft starter is 33 kg.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.