What are the power requirements for the Westermo SDW-550 EtherNet Switch?
The Westermo SDW-550 requires a rated voltage of 12 – 48 VDC, polarity protected, with an operating voltage range of 9.6 – 57.6 VDC. The rated current at 12 VDC power input is 320 mA.
Can the Westermo SDW-550 be mounted on a DIN rail?
Yes, the Westermo SDW-550 is designed for DIN rail mounting. It should be mounted on a 35 mm DIN rail which is horizontally mounted on a wall or cabinet backplate.
What type of cooling does the Westermo SDW-550 use?
The Westermo SDW-550 uses convection cooling. To ensure proper airflow around the device, it is recommended to maintain a minimum spacing of 25 mm above and below and 10 mm to the left and right of the product.
How can I configure the Westermo SDW-550 using DIP switches?
The Westermo SDW-550 features DIP switches under the lid on top of the product for configuration. Note that the settings will only take effect after a reboot, which requires powering off and then on the device.
What type of Ethernet ports does the Westermo SDW-550 have?
The Westermo SDW-550 is equipped with 10/100Base-T/TX Ethernet ports, supporting both 10 Mbit/s and 100 Mbit/s data rates, with manual or auto negotiation for duplex settings.
What is the recommended cable diameter for telecommunication line cords used with the Westermo SDW-550?
To reduce the risk of fire, it is recommended to use telecommunication line cords with a cable diameter of AWG 26 or larger for the Westermo SDW-550.
What should be done if the Westermo SDW-550 is placed in a corrosive environment?
If the Westermo SDW-550 is placed in a corrosive environment, it is important to protect all unused connector sockets with a suitable plug to avoid corrosion attacks on the gold-plated connector pins.
What are the dimensions of the Westermo SDW-550?
The dimensions of the Westermo SDW-550 are 34 x 123 x 121 mm, making it compact and suitable for various industrial environments.
Is the Westermo SDW-550 compliant with any safety or EMC standards?
Yes, the Westermo SDW-550 complies with several safety and EMC standards, including EN 61000-6-2 for immunity in industrial environments and EN 61000-6-4 for emission in industrial environments.
How can I ensure the Westermo SDW-550 is disposed of correctly?
The Westermo SDW-550 should not be treated as unsorted municipal waste. It needs to be handed over to an applicable collection point for recycling electrical and electronic equipment to help reduce hazardous substances and prevent potential negative consequences to the environment and human health.