steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Siemens |
| Part Number | 5SY4120-6 |
| Alternative Part Number | 5SY41206 |
| Product Type | Miniature circuit breaker (MCB) |
| Product Range / Brand | SENTRON |
| Pole Configuration | 1-pole (1P) |
| Tripping Characteristic | Type B |
| Rated Current | 20 A (at 35 °C) |
| Rated Voltage (AC) | 230/400 V AC |
| Rated Frequency | 50/60 Hz |
| Maximum Operating Voltage (DC) | Up to 72 V DC |
| Insulation Voltage (Ui) | 440 V |
| Short-Circuit Breaking Capacity (EN 60898-1) | 10 kA |
| Switching Capacity (IEC 60947-2) | 20 kA |
| Switching Capacity (DC, IEC 60947-2) | 15 kA |
| Breaking Capacity (UL 1077 / CSA) | 5 kA |
| Energy Limiting Class | Class 3 |
| Power Loss (per pole) | 2.2 W (hot operating state) |
| Degree of Protection | IP20 (with connected conductors) |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Mechanical Service Life | Typical 10,000 operating cycles |
| Mounting Method | Quick assembly system (DIN rail mounting) |
| Mounting Position | Any |
| Width | 18 mm (1 modular width unit) |
| Height | 90 mm |
| Depth | 76 mm |
| Installation Depth | 70 mm |
| Net Weight | 165 g |
| Terminal Design | Combined terminals (top and bottom) |
| Solid Conductor Cross-Section | 0.75 to 35 mm² |
| Stranded Conductor Cross-Section | 0.75 to 35 mm² |
| Finely Stranded (with end sleeve) | 0.75 to 25 mm² |
| Connectable Conductor Size (AWG) | 18 to 4 AWG |
| Terminal Tightening Torque | 2.5 to 3.5 N·m |
| Neutral Conductor Switching | No |
| Additional Features | Sealable; touch protection; halogen-free; silicon-free; supplementary devices can be fitted |
| Applicable Standards | IEC/EN 60898-1; IEC/EN 60947-2; UL 1077 |
| Operating Ambient Temperature | -40 °C to +70 °C |
| Storage Ambient Temperature | -40 °C to +75 °C |
| Part Description | Siemens 5SY4120-6 SENTRON miniature circuit breaker, 1-pole Type B, rated 20 A for 230/400 V AC circuits, designed for compact DIN-rail installations where dependable overcurrent protection and straightforward panel layout are required. |
It is a miniature circuit breaker (MCB) used to provide overcurrent and short-circuit protection for electrical circuits in industrial and commercial control panels and distribution assemblies.
It is a single-pole (1P) device, intended to switch and protect one live conductor.
The rated current is 20 A (at 35 °C). Like most MCBs, the permissible continuous current reduces as ambient temperature increases.
It has a Type B tripping characteristic, commonly selected for circuits with low inrush currents such as general-purpose distribution, control circuits, and resistive loads.
It is rated for 230/400 V AC systems and supports 50/60 Hz operation. It can also be used on DC up to 72 V (maximum operating voltage), subject to correct application and installation practices.
It provides 10 kA breaking capacity according to EN 60898 standards, and it is also specified with higher switching capacity figures under IEC 60947-2 (application-dependent).
Yes. It is specified as having properties for main switches in accordance with EN 60204-1.
It is rated IP20 when conductors are connected, meaning it is intended for installation within a suitable enclosure.
Typical dimensions are 90 mm (height) × 18 mm (width, 1 modular unit) × 76 mm (depth), with an installation depth of 70 mm. Net weight is approximately 165 g.
It uses a quick assembly system for standard DIN rail mounting, and it can be installed in any mounting position.
It accepts 0.75 to 35 mm² solid or stranded conductors, and 0.75 to 25 mm² fine-stranded conductors when fitted with appropriate end processing. Recommended screw terminal tightening torque is 2.5 to 3.5 N·m.
Ambient temperature during operation is specified from -40 °C to +70 °C, and during storage from -40 °C to +75 °C.
No. This device does not provide neutral conductor switching.
Yes. It is designed to accept installable supplementary devices. If you need to match a specific function, it is best to confirm the required accessory type and the panel configuration; the base unit is commonly referenced as Siemens 5SY4120-6.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.