What are the rated power specifications for this motor?
The motor is designed with a rated power of 1.6 kW, which is suitable for various industrial applications requiring consistent performance.
Can you provide details on the rated torque and speed of this motor?
Certainly, the motor boasts a rated torque of 7.7 Nm and operates at a rated speed of 2000 RPM, making it an excellent choice for precision-driven tasks.
What is the rotor inertia and mechanical time constant of this motor?
The rotor inertia for the Siemens 1FL5064-0AC21-0AB0 is 20.17 x 10^-4 kgm^2, and it has a mechanical time constant of 2.710 ms, contributing to its dynamic response.
What type of protection does the motor offer?
The motor is equipped with an IP54 protection class, ensuring a good level of protection against dust ingress and splashing water, suitable for various industrial environments.
What are the environmental conditions suitable for operating this motor?
The motor is designed to operate within an ambient temperature range of 0 to 40°C and can be stored at 5 to 40°C. Humidity levels should be below 90% to prevent condensation.
What is the maximum current and torque this motor can handle?
The motor can handle a maximum current of 14 A and can produce a maximum torque of 15.4 Nm, which is ideal for applications that may require short bursts of high power.
What kind of encoder connection does the motor use?
The motor utilises an encoder with a resolution of 2500 counts per turn (C/T), which is integral for precise control in feedback systems.
What are the mounting dimensions for this motor?
The motor has mounting dimensions of 219 mm (length without brake) and 261 mm (length with brake), with a flange size suitable for standard industrial mounting.
Is there any specific drive compatibility for this motor?
Yes, this motor is specifically designed to be compatible with the SIEMENS SINAMICS V60 drive, ensuring seamless integration and optimal performance.
What are the key safety notes regarding the installation of this motor?
It is crucial to ensure that the motor is not directly connected to a three-phase power supply without the appropriate drive, as this could cause damage. Additionally, all electrical work should be performed with the motor powered down, and only by qualified personnel.