steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | C10B34V100 |
| Product Range | ComPacT New Generation |
| Product Name / Series | ComPacT NSX New Generation |
| Device Short Name | NSX100B |
| Device Type | Earth leakage circuit breaker (MCCB with integrated residual current protection) |
| Typical Application | Low-voltage power distribution |
| Poles | 3P |
| Protected Poles | 3D |
| Rated Current (In) | 100 A (at 40 °C) |
| Rated Operational Voltage (Ue) | 440 V AC, 50/60 Hz |
| Network Type | AC |
| Suitability for Isolation | Yes (in accordance with EN/IEC 60947-2) |
| Utilisation Category | Category A |
| Breaking Capacity (Icu) | 25 kA at 380/415 V AC (50/60 Hz) |
| Breaking Capacity (Icu) – additional ratings | 40 kA at 220/240 V AC; 20 kA at 440 V AC; 15 kA at 500 V AC |
| Service Breaking Capacity (Ics) | 25 kA at 380/415 V AC (50/60 Hz) |
| Service Breaking Capacity (Ics) – additional ratings | 40 kA at 220/240 V AC; 20 kA at 440 V AC; 7 kA at 500 V AC |
| Performance Level | B (25 kA at 415 V AC) |
| Trip Unit | MicroLogic 4.2 Vigi (electronic) |
| Protection Functions | L (overload, long time), So (short-time short-circuit with fixed delay), I (instantaneous short-circuit), R (earth-leakage) |
| Trip Unit Rating | 100 A at 40 °C |
| Long-time Pick-up (Ir) | Adjustable, 9 settings; 40…100 A |
| Long-time Delay (tr) | Fixed; 400 s at 1.5 × Ir, 16 s at 6 × Ir, 11 s at 7.2 × Ir |
| Thermal Memory | 20 minutes before and after tripping |
| Short-time Pick-up (Isd) | Adjustable; 1.5…10 × Ir |
| Short-time Delay (tsd) | Fixed; 0.02 s |
| Instantaneous Pick-up (Ii) | Fixed; 1500 A |
| Earth-leakage Protection | Integrated (Vigi) |
| Earth-leakage Class | Class A |
| Earth-leakage Sensitivity (IΔn) | Adjustable: 30 mA, 100 mA, 300 mA, 500 mA, 1 A, 3 A, 5 A; OFF selectable via rotary switch |
| Earth-leakage Time Delay (Δt) | Adjustable: 0 ms, 60 ms, 150 ms, 500 ms, 1 s |
| Control Type | Toggle |
| Mounting Mode | Fixed |
| Mounting Support | Backplate |
| Mounting Position | Horizontal or vertical; flat on the back |
| Connection Orientation | Front (upside and downside connection) |
| Connection Pitch | 35 mm |
| Electrical Auxiliaries Slots | 5 slot(s) |
| Zone Selective Interlocking (ZSI) | Without |
| Local Signalling | Green flashing LED (ready to operate); orange LED at 90% Ir (overload); red LED at 105% Ir (overload) |
| Rated Insulation Voltage (Ui) | 500 V AC (50/60 Hz) |
| Impulse Withstand Voltage (Uimp) | 8 kV |
| Overvoltage Category | Class II |
| Electrical Shock Protection Class | Class II |
| Pollution Degree | 3 (IEC 60664-1) |
| Degree of Protection | IP40 (IEC 60529) |
| Impact Resistance | IK07 (IEC 62262) |
| Standards | EN/IEC 60947 |
| Product Certifications | CCC, EAC, Marine |
| Ambient Temperature (Operation) | -25…70 °C |
| Ambient Temperature (Storage) | -50…85 °C |
| Relative Humidity | 0…95% |
| Operating Altitude | 0…2000 m without derating; 2000…5000 m with derating |
| Mechanical Durability | 50,000 cycles |
| Electrical Durability | 50,000 cycles at 440 V (In/2); 30,000 cycles at 440 V (In); 20,000 cycles at 690 V (In/2); 10,000 cycles at 690 V (In) |
| Power Dissipation per Pole | 5.8 W (L1 & L3); 3.9 W (L2); 5.8 W (N) |
| Dimensions (W × H × D) | 105 mm × 161 mm × 86 mm |
| Net Weight | 2.05 kg |
| Product Description | Schneider Electric ComPacT NSX100B earth leakage circuit breaker with MicroLogic 4.2 Vigi electronic trip unit, designed for dependable 3‑pole distribution protection. Provides adjustable overload and short-circuit settings plus integrated Class A residual current protection with selectable sensitivity and time delay for flexible coordination in low-voltage AC installations. |
It is a fixed-mount earth-leakage circuit breaker for AC distribution, combining overcurrent and earth-leakage protection in a single unit. This device uses an electronic trip unit (MicroLogic 4.2 Vigi).
It is intended for AC networks at 50/60 Hz, with a rated operational voltage up to 440 V AC.
It is a 3-pole device with 3D (three protected poles), meaning all three phases are protected by the trip unit.
The trip unit rating is 100 A at 40 °C, and the long-time pickup (Ir) is adjustable across 9 settings from 40 A to 100 A.
It provides: L (overload/long-time), So (short-time with fixed delay), I (instantaneous), and R (earth-leakage) protection functions.
Its rated ultimate short-circuit breaking capacity (Icu) is 25 kA at 380/415 V AC, 20 kA at 440 V AC, and 40 kA at 220/240 V AC (per IEC 60947-2).
Yes. Earth-leakage sensitivity (IΔn) is adjustable across 30 mA, 100 mA, 300 mA, 500 mA, 1 A, 3 A, and 5 A, and can also be set to OFF using the IΔn rotary switch.
Yes. The earth-leakage time delay (Δt) is adjustable with settings of 0 ms, 60 ms, 150 ms, 500 ms, and 1 s.
Short-time pickup (Isd) is adjustable from 1.5 to 10 × Ir with a fixed short-time delay (tsd) of 0.02 s. Instantaneous pickup (Ii) is fixed at 1500 A.
It is a fixed circuit breaker designed for backplate mounting. Connections are front-connected (upside and downside), with a 35 mm connection pitch.
It is rated IP40 and IK07. Typical operating ambient range is -25 to 70 °C, with storage from -50 to 85 °C, and it is specified for operation up to 2000 m without derating (2000 m to 5000 m with derating).
Yes. It includes local LED indications: a green flashing LED for ready-to-operate, an orange LED at 90% Ir for overload, and a red LED at 105% Ir for overload.
Overall dimensions are approximately 105 mm (W) × 161 mm (H) × 86 mm (D), with a net weight around 2.05 kg.
Yes. The unit provides 5 slots for electrical auxiliaries (availability and selection depend on the required auxiliary function).
Yes. It is suitable for isolation in accordance with EN/IEC 60947-2.
Class A earth-leakage protection is designed to detect residual currents for AC and pulsating DC components, making it suitable for many modern loads where non-sinusoidal leakage can occur.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.