steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | Schneider Electric |
| Part Number | 140CPU43412U |
| Product Range / Family | Modicon Quantum |
| Category | PLC CPU (Unity processor) |
| Overview | High-performance Modicon Quantum Unity processor designed to act as the central controller for Quantum PLC racks, providing fast execution, generous internal memory, and integrated serial and Modbus Plus communications for industrial automation systems. |
| Processor Clock Frequency | 66 MHz |
| Internal Memory (RAM) | 1056 kB |
| Bus Current Requirement | 1800 mA |
| Local Racks Supported | 2 local rack(s) |
| Distributed I/O Stations | Up to 63 station(s) (via Modbus Plus networks) |
| Modbus Plus Networks Supported (Distributed I/O) | Up to 3 network(s) |
| Remote I/O Stations (S908) | Up to 31 remote I/O station(s) (up to 2 S908 remote I/O rack(s)) |
| Remote I/O Stations (Ethernet) | 0 ethernet remote I/O rack(s) stated for this CPU configuration |
| Discrete I/O Capacity (Local) | Unlimited (up to 26 slots max) – local |
| Discrete I/O Capacity (Distributed, per Modbus Plus network) | 8000 inputs / 8000 outputs per network |
| Discrete I/O Capacity (Remote) | 31744 inputs / 31744 outputs – remote |
| Analogue I/O Capacity (Local) | Unlimited (up to 26 slots max) – local |
| Analogue I/O Capacity (Distributed, per Modbus Plus network) | 500 inputs / 500 outputs per network |
| Analogue I/O Capacity (S908 Remote) | 1984 inputs / 1984 outputs |
| Integrated Communication Ports | 2 × Modbus ports; 1 × Modbus Plus port |
| Communication Connector Type | SUB-D 9 (DB9) |
| Electrical Connections (Physical) | 2 female SUB-D 9 connectors for Modbus; 1 female SUB-D 9 connector for Modbus Plus |
| Communication Port Mode Selection | Slide switch: ASCII / RTU / Memory |
| Memory Protection / Run Control | Key switch: memory start/stop and memory protection |
| Typical Task Structure | 1 cyclic/periodic master task; 1 periodic fast task; 16 timer interrupt tasks; 64 I/O interrupt tasks; 64 interrupt tasks; no auxiliary task |
| Execution Time per Instruction (Typical Range) | Boolean: 0.12…0.585 µs; Word: 0.12…0.585 µs; Fixed-point arithmetic: 0.1…0.27 µs; Floating point: 0.1…0.27 µs |
| Throughput (Typical) | 1.86 Kinst/ms (100% Boolean) or 2.49 Kinst/ms (65% Boolean / 35% numerical) |
| System Overhead (Typical) | 1 ms (master task); 0.2 ms (fast task) |
| Local Indicators (LEDs) | ERROR A (red, Modbus Plus comms error); BAT LOW (red, battery absent/low); memory port write-protect (orange); READY (green); RUN (green); Modbus activity (green); Modbus Plus activity (green) |
| Optional Communication Modules (Max) | Up to 6 optional modules (e.g., Ethernet, Modbus, Modbus Plus, Profibus DP, Sy/Max) |
| Product Certifications | CE, CSA, UL |
| Standards / Approvals | HazLoc |
| Country of Origin | France |
| Commodity Code (HS) | 853890 |
It is a Unity processor (CPU) for the Modicon Quantum automation platform. It executes the control application, manages I/O updates, handles communications, and coordinates local and remote Quantum racks within a PLC system.
It has 1056 kB of internal RAM for the control application and related data.
The module operates with a 66 MHz clock frequency.
It includes integrated ports for Modbus Plus (1 port) and Modbus (2 ports), providing common connectivity options for Quantum networks and serial Modbus communications.
It uses SUB-D 9 connectors: one female SUB-D 9 for Modbus Plus, and two female SUB-D 9 connectors for the Modbus ports.
The bus current requirement is 1800 mA, which should be considered when sizing the rack power supply and overall backplane load.
Key indicators include: communications activity on Modbus Plus and Modbus (green), CPU status (READY green and RUN green), memory write protection status (MEM PRT orange), battery status (BAT LOW red), and Modbus Plus error indication (ERROR A red).
Yes. It has a key switch used for memory start/stop and memory protection functions, plus a slide switch used to select the communication port mode (ASCII/RTU/Memory).
It supports up to 2 local racks in a Modicon Quantum configuration.
It supports up to 63 distributed I/O stations (on Modbus Plus networks) and up to 31 remote I/O stations using S908 remote I/O racks (with up to 2 remote racks referenced in the product characteristics).
Typical limits include up to 8000 inputs and 8000 outputs per Modbus Plus distributed network, and up to 31744 inputs and 31744 outputs for remote I/O. Local discrete I/O capacity is shown as unlimited (with a practical rack slot limit of 26).
Typical limits include up to 500 analogue inputs and 500 analogue outputs per Modbus Plus distributed network, and up to 1984 analogue inputs and 1984 analogue outputs on S908 remote I/O. Local analogue I/O is listed as unlimited (with a practical rack slot limit of 26).
Typical execution time ranges are 0.12 to 0.585 µs for Boolean and word instructions, and 0.1 to 0.27 µs for fixed-point and floating-point arithmetic (depending on instruction type and conditions).
It supports a structured task model including 1 cyclic/periodic master task, 1 periodic fast task, 16 timer interrupt tasks, 64 I/O interrupt tasks, and 64 interrupt tasks (no auxiliary task).
Yes. The processor supports application-specific I/O features including counters, high-speed interrupt inputs, serial link functions, and accurate time stamping.
It supports up to 6 optional modules from categories such as Ethernet, Modbus, Modbus Plus, Profibus DP, and Sy/Max, depending on the overall Quantum rack configuration.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.