What is the primary function of this communication module?
The primary function of this communication module is to serve as an IO-Link master, enabling the operation of up to four IO-Link devices. It can also connect standard digital sensors or actuators to each port.
What are the dimensions of this communication module?
The dimensions of the communication module are 14.9 mm in width, 62.2 mm in height, and 62 mm in depth.
What is the degree of protection for this module?
This module has a degree of protection rated at IP20.
What is the operating temperature range for this module?
The operating temperature range for this module is from -25 °C to 60 °C.
How many IO-Link ports does this module support?
This module supports up to four IO-Link ports.
What is the nominal input voltage for the digital inputs?
The nominal input voltage for the digital inputs is 24 V DC.
What type of connection method is used for the IO-Link ports?
The IO-Link ports use a push-in connection method.
What is the maximum sensor current per channel?
The maximum sensor current per channel is 500 mA.
What is the nominal current per channel for digital outputs?
The nominal current per channel for digital outputs is 200 mA.
What standards and regulations does this module comply with?
This module complies with various standards and regulations, including EN 61000-6-2 for noise immunity and EN 61000-6-4 for noise emission.