steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | 3038435 |
| Manufacturer | Phoenix Contact |
| Part Name | Disconnect Terminal Block - ST 2,5-TG |
| Connection Type | Spring-cage connection |
| Conductor Cross Section | 0.08 mm² - 4 mm² |
| AWG | 28 - 12 |
| Nominal Current | 20 A |
| Nominal Voltage | 400 V |
| Length | 60.5 mm |
| Width | 5.2 mm |
| Colour | Grey |
| Assembly | NS 35/7.5, NS 35/15 |
| Number of Levels | 1 |
| Number of Connections | 2 |
| Nominal Cross Section | 2.5 mm² |
| Insulating Material | Polyamide (PA) |
| Flammability Rating | UL 94 V0 |
| Area of Application | Railway industry, Mechanical engineering, Plant engineering |
| Rated Surge Voltage | 6 kV |
| Pollution Degree | 3 |
| Overvoltage Category | III |
| Minimum Stripping Length | 8 mm |
| Maximum Stripping Length | 10 mm |
| Conductor Cross Section (Solid) | Min: 0.08 mm², Max: 4 mm² |
| Conductor Cross Section (Flexible) | Min: 0.08 mm², Max: 2.5 mm² |
| Conductor Cross Section (AWG) | Min: 28, Max: 12 |
| Conductor Cross Section (Flexible, with Ferrule without Plastic Sleeve) | Min: 0.14 mm², Max: 2.5 mm² |
| Conductor Cross Section (Flexible, with Ferrule with Plastic Sleeve) | Min: 0.14 mm², Max: 2.5 mm² |
| 2 Conductors with Same Cross Section, Stranded, TWIN Ferrules with Plastic Sleeve | Max: 0.5 mm² |
| Connection Method | Spring-cage connection |
| Internal Cylindrical Gage | A3 |
| Standards and Regulations | IEC 60947-7-1 |
The Phoenix Contact 3038435 is a high-quality disconnect terminal block designed for efficient and reliable electrical connections. With a robust spring-cage connection type, it accommodates a wide range of conductor cross sections from 0.08 mm² to 4 mm², making it versatile for various applications. This terminal block is particularly suitable for use in the railway industry, mechanical engineering, and plant engineering, thanks to its durable construction and compliance with IEC 60947-7-1 standards. Its compact design, with a width of just 5.2 mm, allows for space-saving installations, while the grey polyamide insulating material ensures excellent performance and safety.
This part uses a spring-cage connection, which is known for its reliability and ease of use in various applications.
The nominal current rating is 20 A, and the nominal voltage rating is 400 V, making it suitable for a range of electrical applications.
The part measures 60.5 mm in length and 5.2 mm in width, allowing for compact installation in electrical systems.
The conductor cross section ranges from 0.08 mm² to 4 mm², accommodating various wire sizes for flexible use.
Yes, this part is tested and suitable for railway applications, ensuring high performance in demanding environments.
The part has a flammability rating of V0 according to UL 94, indicating its high resistance to fire.
The part is grey, which is a standard colour for many industrial components, ensuring it blends well with other equipment.
The maximum load current is 20 A when used with a 4 mm² conductor cross section, providing robust performance in electrical circuits.
This part is rated for pollution degree 3 and overvoltage category III, making it suitable for industrial environments with higher levels of pollution and overvoltage.
The rated surge voltage is 6 kV, offering protection against voltage spikes in electrical systems.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.