steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Manufacturer | ABB |
| Part Number | 2CCS861001R0104 |
| Model / Series | S800S |
| Product Designation | S801S-C10 |
| Product Type | Miniature circuit breaker (MCB) / supplementary protector |
| Poles | 1-pole |
| Tripping Characteristic | C-curve (suited to loads with moderate inrush currents) |
| Rated Current | 10 A |
| Protection Mechanisms | Thermal trip for overload protection and electromechanical trip for short-circuit protection |
| Termination Type | Cage terminal |
| Current Limiting | Yes |
| Rated Voltage (AC) | 240 V AC, 277 V AC, 347 V AC |
| Maximum Operating Voltage Range | Up to 400/690 V (AC) and suitable for DC applications |
| Rated Short-Circuit Capacity (AC) | 25 kA at 230/400 V AC |
| Ultimate Short-Circuit Breaking Capacity | 50 kA at 240/415 V AC; 30 kA at 254/440 V AC; 6 kA at 400/690 V AC; 30 kA at 125 V DC |
| Interrupting Rating (UL 1077) | 30 kA at 240 V AC; 14 kA at 277 V AC; 6 kA at 347 V AC |
| Power Loss | 1.5 W per pole (at rated operating conditions) |
| Standards / Approvals | IEC/EN 60898-1, IEC/EN 60947-2, UL 1077 |
| Typical Use (UK/EU wording) | Compact 1-pole protective device for residential, commercial, and industrial control circuits where dependable overload and short-circuit protection is required |
It is a high-performance miniature circuit breaker (supplementary protector) designed to protect circuits against overloads and short-circuits by automatically disconnecting the supply when abnormal current conditions occur.
It uses two tripping mechanisms: a thermal mechanism for overload protection and an electromechanical mechanism for short-circuit protection.
It is a 1-pole device.
The rated current is 10 A (often referenced as S801S-C10, ABB catalogue no. 2CCS861001R0104).
A C-curve breaker is typically selected where moderate inrush currents may occur (for example, some inductive loads), helping to reduce unwanted tripping while still providing reliable protection.
It can be used on AC systems and is suitable for applications up to 400/690 V, depending on the system and required breaking capacity. Specific AC rated voltages listed include 240 V AC, 277 V AC, and 347 V AC.
Yes. It is suitable for DC use as well, with a listed DC breaking capacity (for example, 30 kA at 125 V DC).
It is a current-limiting device with a maximum ultimate short-circuit breaking capacity of up to 50 kA at 240/415 V AC (with other rated capacities depending on voltage).
Examples of listed ratings include: 25 kA rated short-circuit capacity at 230/400 V AC, and ultimate breaking capacities such as 50 kA at 240/415 V AC, 30 kA at 254/440 V AC, and 6 kA at 400/690 V AC.
It is designed in line with IEC/EN 60898-1 and IEC/EN 60947-2, and it also carries a UL 1077 reference in the published specifications.
It features cage terminals, which are commonly chosen for secure conductor clamping and consistent connections.
The specified power loss is 1.5 W per pole at rated operating conditions.
It is commonly applied across residential, commercial, and industrial installations where a supplementary protective device with high short-circuit performance is required.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.