steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 weeks ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | JUSP-TA50P |
| Alternative Part Number | JUSPTA50P |
| Manufacturer | Yaskawa |
| Category | Drive Parts |
| Ambient Usage Temperature | 0 ~ +40°C (32° ~ 104°F) |
| Storage Temperature | -25 ~ +85°C (-13° ~ 185°F) |
| Ambient Usage Humidity | 30 ~ 95%RH (no condensation) |
| Storage Humidity | 5 ~ 95%RH (no condensation) |
| Corrosion Resistance | No flammable or corrosive gas |
| Altitude | 2000m or less above sea level |
| Noise Resistance | Normal Mode: 1500Vp-p, Common Mode: 1500Vp-p, Pulse Width: 100ns/1µs, Pulse Rise Time: 1ns |
| Vibration Resistance | Vibration Amplitude/Acceleration: 10 ≤ f < 57Hz, Zero to Peak Amplitude: 0.075mm, 57 ≤ f < 150Hz, Fixed Acceleration: 9.8m/s² |
| Shock Resistance | Peak Acceleration: 147m/s², Usage Time: 11ms |
| Grounding | Type 3 Grounding |
| Cooling Type | Natural Air Cooled |
| External Dimensions | W 45mm x H 142mm x D 129mm |
| Memory | Flash: 2MB, RAM: 2MB (battery backed) |
| Communication Ports | 1 RS-232C port, 1 RS-422/485 port |
| Baud Rate Setting | 9.6k/19.2 kbps |
| Protocol | MEMOBUS, No Protocol |
| Display LEDs | Module Status Display LEDs (READY, RUN, ALM, BATALM, PRT1, PRT2), Mechatrolink Operation Display LEDs (RX, TX) |
| DIP Switches | RUN, INIT, TEST, FLASH, PP, COPY |
| Input Signals | Input Points: 8, Input Format: Sinking or Sourcing, Isolation: Optical, Voltage: 24VDC ±20% |
| Output Signals | Output Points: 8, Output Format: Sinking output, Output Type: Transistor output, Isolation: Optical |
| Load Voltage | 24VDC±20% |
| Load Current | 100mA/output |
| Output Protection | 1 common fuse, Fuse Rating: 1.5A (fusing time: 5s or less at 3A) |
| Response Time | OFF to ON 0.25ms or less, ON to OFF 1ms or less |
The JUSP-TA50P is a drive part used in industrial automation for controlling and interfacing with Yaskawa servo drives. It facilitates communication and power connections between the drive and other components within a control system.
The JUSP-TA50P is specifically designed to interface with Yaskawa servo drives and motors. It is not intended for use with other types of motors and may not be compatible with them.
The JUSP-TA50P supports various communication protocols including RS-232C, RS-422/485, and MEMOBUS, allowing it to interface with a range of devices and controllers for flexible system integration.
Proper installation of the JUSP-TA50P involves following the manufacturer's guidelines for mounting orientation, cable connections, and grounding. It's important to ensure that the drive system, control system, and power system are separate to avoid interference.
The JUSP-TA50P should operate within an ambient temperature range of 0 to 40°C and a humidity range of 30 to 95% RH without condensation. It should also be used in environments free from flammable or corrosive gases.
If communication errors occur, check the wiring and connections for the communication cables and connectors, verify the power supply voltage and connections, and ensure the correct baud rate and terminator settings are applied. Refer to the troubleshooting section of the hardware manual for more detailed guidance.
Yes, the JUSP-TA50P is capable of handling external encoder inputs. It supports various input formats including quadrature, pulse and direction, and can handle a maximum frequency of 1MHz.
The LED indicators on the JUSP-TA50P provide visual feedback on the status of the device, including power, communication, and error statuses. They are an essential tool for diagnostics and monitoring the operational state of the drive part.
The DIP switches on the JUSP-TA50P are used to set various operational parameters such as flash memory operation, initial settings, and communication protocols. The configuration should be done according to the specific requirements of your application as outlined in the hardware manual.
The flash memory on the JUSP-TA50P is used to store user-created programs and configurations. It retains the data even when power is not supplied, allowing the device to quickly start up with the saved settings upon power restoration.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.