steve
Got hold of Sime for a Carrier card for…
Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime
3 months ago
Full 12-month warranty
Available for dispatch immediately
We deliver worldwide
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
All orders are subject to product availability. See our T&Cs.
Ask our team
1. Email confirmation
You will get an email confirming that we have received your enquiry.
2. Dedicated Account Manager
One of our team will be in touch to confirm your part(s) specification and condition.
3. Your quote
You will receive a comprehensive quote tailored to your specific needs.
| Specification | Description |
|---|---|
| Part Number | UE10-3OS2D0 |
| Alternative Part Number | UE103OS2D0 |
| Manufacturer | Sick |
| Safety Integrity Level | SIL3 (IEC 61508), Category 4 (EN ISO 13849) |
| Performance Level | PL e (EN ISO 13849) |
| B10d Value | 1.26 x 10^6 operations (AC-15, 230 V, I = 1.5 A) |
| PFHD | 3.0 x 10^-8 (EN ISO 13849) |
| TM (Service Life) | 20 years (EN ISO 13849) |
| Supply Voltage | 24 V DC (15 V DC ... 30 V DC) |
| Input Current | ≤ 500 mA |
| Power Consumption | 2.4 W (DC) |
| Rated Insulation Voltage (Ui) | 300 V AC |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Test Voltage | 2 kV (50 Hz) (EN 60439-1) |
| Output Contact Type | Forced guided |
| Contact Material | Silver alloy, gold plated |
| Switching Voltage | 10 V AC ... 230 V AC / 10 V DC ... 300 V DC |
| Current Rating per OSSD | 5 mA ... 6 A |
| Total Current | ≤ 12 A |
| Utilisation Category | AC-15/DC-13 (EN 60947-5-1) |
| Mechanical Life (Relay Contacts) | 1 x 10^7 operations |
| Electrical Life (Relay Contacts) | 2 x 10^6 operations |
| Dimensions (W x H x D) | 22.5 mm x 114 mm x 96.5 mm |
| Pollution Degree | 3 (EN 50178) |
| Weight | 0.2 kg |
| eCl@ss | 27371819 (eCl@ss 6.0 to eCl@ss 12.0) |
| ETIM | EC001449 (ETIM 5.0 to ETIM 8.0) |
A safety relay is a device that implements safety functions. In the case of the UE10-3OS2D0, it is used to monitor a variety of safety devices such as emergency stop buttons, safety guards, light curtains, and more, ensuring that these safety circuits operate correctly and provide the necessary protection for both machinery and personnel.
Yes, the UE10-3OS2D0 can be integrated with other safety systems. It is designed to work in conjunction with a variety of safety devices and can be part of a larger safety network within an industrial setting.
The UE10-3OS2D0 supports several output configurations including normally open (NO) safety outputs and normally closed (NC) auxiliary outputs, which can be used for indicating the status of the safety circuit and for diagnostic purposes.
The safety category of the relay is determined by the standards it meets, such as EN ISO 13849 or IEC 61508. The UE10-3OS2D0 is designed to meet high safety standards, typically achieving a Category 4 / PLe according to EN ISO 13849, which is suitable for the highest level of safety for control systems.
The typical response time for the UE10-3OS2D0 safety relay is less than or equal to 20 milliseconds, which allows for quick reaction to any safety incidents, minimising potential hazards.
The expected service life of a safety relay like the UE10-3OS2D0 depends on the number of operating cycles it can perform. It has a mechanical life expectancy of up to 10 million operating cycles and an electrical life expectancy of up to 2 million operating cycles under specified conditions.
The UE10-3OS2D0 requires a power supply of 24 V DC with an input current of less than or equal to 500 mA, which is standard for most industrial control systems.
Forcibly guided contacts in a safety relay like the UE10-3OS2D0 ensure that the contacts are mechanically linked. This means that if one contact fails, the other contacts will not be able to close, preventing any unsafe conditions due to contact welding or other failures.
Yes, the UE10-3OS2D0 is well-suited for monitoring emergency stop buttons as well as other safety devices such as safety door switches and light curtains, ensuring that they function correctly to maintain a safe working environment.
The UE10-3OS2D0 typically includes self-diagnostic features and can be tested using manual test procedures to ensure it is functioning correctly. Regular testing is an important part of maintaining the integrity of the safety system.
This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.
All parts new or reconditioned are covered by EU Automation 12 month warranty
No hassle returns policy
Dedicated customer support team
We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.
Payment optionsWe accept Bank transfers and the following methods of payment:
All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.
Global supplier of quality automation and control components
Dispose of your old unit by exchanging it for a working part.
A comprehensive repair service for faulty equipment.
Discover how we do our part to keep your production lines moving.