Schneider Electric METSECT5DA060 is a PowerLogic current transformer designed for reliable current measurement on busbar installations. It provides a 600/5 A ratio with a 5 A secondary, suitable for connection to metering and monitoring equipment where consistent accuracy is required. The transformer is tropicalised for enhanced resistance in demanding panel environments and features a double output configuration for flexible wiring arrangements.

Built for use on busbars up to a 65 x 32 mm opening, the unit mounts securely using an insulated locking screw and includes sealing provision. It supports operational voltages up to 720 V AC (50/60 Hz) and offers IP20 protection. Accuracy performance is rated Class 0.5 at 8 VA and Class 1 at 12 VA, with 3 kV insulation and 3 kV impulse withstand capability. The METSECT5DA060 complies with IEC 61869-2 and VDE 0414 and is specified for operation from -25 to +60 °C with up to 95% relative humidity.
Specification Description
Manufacturer Schneider Electric
Part Number METSECT5DA060
Product Type Current transformer (CT)
Range / Series PowerLogic
Application Measurement CT for busbar installations
CT Type Tropicalised (suited to humid/condensing environments)
Rated Primary Current 600 A
Rated Secondary Current 5 A
Current Ratio 600/5
Secondary Outputs Double output (two secondary windings)
Accuracy Class (Burden) Class 0.5 at 8 VA; Class 1 at 12 VA
Maximum Safety Factor 5
Rated Operational Voltage (Ue) < 720 V AC, 50/60 Hz
Rated Insulation Voltage (Ui) 3 kV
Impulse Withstand Voltage (Uimp) 3 kV
Conventional Thermal Current (Ith) 36 kA (free air)
Dynamic Withstand Current 2.5 × Ith
Electrical Insulation Class Class B
Degree of Protection IP20
Mounting Mode Insulated locking screw
Mounting Support Busbar
Busbar Opening (Inner) 65 × 32 mm
Overall Dimensions (Outside) Width 90 mm; Height 94 mm
Depth Frame 40 mm; Total 87 mm
Sealing With sealing provision
Operating Temperature -25 to +60 °C
Relative Humidity 0 to 95%
Standards IEC 61869-2; VDE 0414
Certifications CE; EAC
Net Weight 0.541 kg
Part Description Schneider Electric PowerLogic tropicalised current transformer for busbar mounting, providing a 600 A to 5 A conversion with double secondary output for metering circuits, rated for installations up to 720 V AC with IP20 protection and screw-secured insulated mounting.

What does this current transformer do in a power monitoring system?

It converts a high primary current flowing through a busbar into a standard 5 A secondary current that can be measured by meters, protection relays, or power monitoring equipment.

What is the current ratio and rated primary current?

The ratio is 600/5, meaning 600 A on the primary corresponds to 5 A on the secondary at rated conditions.

What secondary current does it provide?

It provides a 5 A secondary output for connection to compatible measuring or protection devices.

What accuracy classes and burdens are supported?

It is rated Class 0.5 at 8 VA and Class 1 at 12 VA, allowing you to select the class/burden combination that matches the connected load and required measurement performance.

What busbar size will fit through the window?

It is designed for busbars up to 65 x 32 mm (opening of bars 65 x 32).

What are the overall dimensions for panel layout planning?

Outside width is 90 mm and outside height is 94 mm. Depth is 40 mm (frame) and 87 mm (total).

How is it mounted onto the busbar?

It uses an insulated locking screw mounting method and is intended for direct mounting on a busbar.

What is the maximum operational voltage it is intended to be used with?

The rated operational voltage is below 720 V AC at 50/60 Hz.

What insulation ratings are provided?

Rated insulation voltage (Ui) is 3 kV and rated impulse withstand voltage (Uimp) is 3 kV. Electrical insulation class is Class B.

What is the enclosure protection rating?

It has an IP20 degree of protection, intended for installation inside suitable electrical enclosures.

What short-circuit withstand ratings are specified?

Conventional free-air thermal current (Ith) is 36 kA, and the dynamic withstand current is 2.5 x Ith.

What environmental conditions is it designed to operate in?

Operating ambient temperature is -25 to +60 °C, with permissible relative humidity from 0 to 95%.

Is the unit supplied with any sealing provision?

Yes, sealing is provided. This can help with tamper indication requirements in metering installations, depending on the overall panel design.

What standards does it conform to?

It is specified against IEC 61869-2 and VDE 0414.

What does 'tropicalised' mean in this context?

It indicates the current transformer is designed for reliable performance in harsher environmental conditions such as high humidity, within the stated operating limits (this model is described as tropicalised for busbar use).

What is the maximum safety factor and what does it indicate?

The maximum safety factor is 5. It indicates the CT’s behaviour under high current conditions relative to instrument protection, as defined by the product’s specification (for reference, this model is Schneider METSECT5DA060).

  • Converting high busbar currents into a standard 5 A secondary signal for panel instruments and energy meters
  • Sub-metering and tenant billing applications in commercial buildings where 600 A feeders need monitoring
  • Load profiling and demand monitoring on distribution boards to support energy reduction initiatives
  • Feeder and incomer current measurement within switchboards and switchgear using 32 × 65 mm busbars
  • Power monitoring for large HVAC plant, chillers, and pump systems to track operational consumption
  • Current sensing for generator and mains incomer metering to compare sources and operating modes
  • Monitoring high-current motor control centres to identify heavily loaded circuits and imbalances
  • Input current measurement for power quality and power monitoring equipment that requires a 600/5 CT ratio
  • Multi-circuit measurement setups using the double secondary output to feed separate metering functions
  • Industrial and infrastructure electrical distribution monitoring where a tropicalised CT is preferred for harsher environments

This content has been produced using multiple sources. EU Automation takes no responsibility for the accuracy of this information. Always consult the original equipment manufacturer for the most up to date instructions and information.

Delivery

  • Logistic partners UPS, FedEx and DHL
  • International delivery available
  • Premium nine hour delivery service available to anywhere in Europe
  • Same day dispatch from group stock

Warranty

All parts new or reconditioned are covered by EU Automation 12 month warranty

Returns

No hassle returns policy

Dedicated customer support team

Trade Credit

We understand that credit is a necessary part of business and offer credit agreements on request, subject to status.

Payment options

We accept Bank transfers and the following methods of payment:

All transactions are handled securely by HSBC and HSBC Merchant Services. For more information, please visit our dedicated payments page.

Services

Sourcing your part

Global supplier of quality automation and control components

Service Exchange

Dispose of your old unit by exchanging it for a working part.

Repair

A comprehensive repair service for faulty equipment.

Customer reviews

5 out of 5 stars steve

Got hold of Sime for a Carrier card for…


Got hold of Sime for a Carrier card for a chiller. Machine down in a factory. Received the new card in express time machine and plant now up and running fantastic service form Sime

3 months ago

5 out of 5 stars Daniel

Excellent customer service...


Alex Bailey is my main point of contact at EU Automation...he is extremely friendly, has exceptional customer service skills and always offers great pricing & lead times.

4 months ago

5 out of 5 stars Jerry Schrink

Tom Higgins provided amazing service


Tom Higgins provided great prompt service. I contacted Tom by phone and within 10 minutes there was a quote in my in box. WOW Thank you Tom and Thank you EU Automation!

5 months ago

5 out of 5 stars Paulo Pereira

Excellent service and communication…


Excellent service and communication from Alex Bailey. He truly goes above and beyond to ensure his clients are 100% satisfied. The entire process was seamless, and his attention to detail made a huge difference. Highly recommended for anyone looking for amazing service!

5 months ago

5 out of 5 stars Gary

Tom Higgins did a great job at getting…


Tom Higgins did a great job at getting us the part we needed. He saw a concern with the part a verified before shipping.

5 months ago

5 out of 5 stars Lessle Smith

Thomas Higgins has gone above and…


Thomas Higgins has gone above and beyond to make things happen for my facility. His customer service and knowledge were an asset in helping me with my order and the logistics challenges!

6 months ago

Factory worker carrying automation parts box.

Our world, made possible by manufacturing. Manufacturing made possible by EU Automation.

Discover how we do our part to keep your production lines moving.

FAQs

View all FAQs

We're here when you need us